Page 151
Executive Override2-125 Chapter 2 - Features and Operation 4. Press the EXECUTIVE OVERRIDE BLOCK flexible button (Button #13). The following message displays: 5. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disabled [1] = Enabled 6. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … Executive Override Blocking is disabled at all stations. Conditions » Only one station at a time can be programmed when using a flexible station number. » When in Flash 51...
Page 152
2-126Executive Override Chapter 2 - Features and Operation Barge-In Warn Tone Description When the Barge-in Warn Tone feature is enabled, it produces a tone to notify a station that another station is about to use Executive Override or the Barge-in feature to cut into the existing conversation. Programming Steps 1. Press the BARGE IN WARN TONE flexible button (FLASH 06, Button #1). The following message displays: 2. Enter a 0 or 1 on the dial pad to enable/disable the conference tone. [0] = Disabled...
Page 153
Executive / Secretary Pairs2-127 Chapter 2 - Features and Operation Executive / Secretary Pairs Description There are four Executive/Secretary pairs available. When an Executive station is busy or in DND, intercom calls and transfers are automatically routed to the designated Secretary. The assigned secretary may Camp On to the Executive Station when the station is busy or in Do-Not-Disturb. There can be only one pairing of stations, with no duplicates. You cannot pair Executive 100 to Secretary 101,...
Page 154
2-128External Day Ring Chapter 2 - Features and Operation External Day Ring Description The system can be programmed so CO lines marked for UDA provides ringing out of the external page ports when the system is in the Day Mode. Programming Steps 1. Press the EXT DAY RING flexible button (FLASH 06, Button #5). The following message displays: 2. Enter a 0 or 1 on the dial pad to enable/disable External Day Ring. [0] = Disabled [1] = Enabled 3. Press HOLD to save the entry. A confirmation tone sounds....
Page 155
Fixed Station/Port Number2-129 Chapter 2 - Features and Operation Fixed Station/Port Number Description When a station dials the feature code 611 on a display telephone, it will display the Fixed Station/Port Number for that telephone. For example, when using flexible numbering some programming steps require the “FIXED” code. This code allows you to dial 611 and quickly determine the fixed port for that station. SINGLE LINE TELEPHONE Not applicable Flash Rates (Programmable) Description Fixed and...
Page 156
2-130Flexible Button Assignment Chapter 2 - Features and Operation Flexible Button Assignment Description If you have buttons on your telephone, you may program them to suit your own needs. This feature also allows programming of flexible buttons from a remote location (off-site). Range programming can also assign these buttons to multiple stations. The possible functions you may assign to these buttons include: Outside Line -- Automatically accesses assigned line. (User programmable) DSS/BLF --...
Page 157
Flexible Button Assignment2-131 Chapter 2 - Features and Operation Flexible Button Description Each Digital Telephone has 8, 12, or 24 flexible buttons that can be programmed. One of the following six operations can be selected in programming for each button. To assign a Flexible Button (user programmable): Enter [BB], [0], [HOLD] When a button is assigned as a flexible button [0], the user can program any features or functions on the buttons to which they have access. To assign a CO Line Button: Enter...
Page 158
2-132Flexible Button Assignment Chapter 2 - Features and Operation To unassign (lock out) a button: Enter [BB], [#], [HOLD] If SLT stations must be programmed for off-hook preference, program the desired CO line, or CO line group the SLT must access when going off-hook. To assign a CO Line for an SLT (with off-hook preference) Enter [01], [1], [LLL], [HOLD] LLL = CO Line Number To assign a CO Line Group for an SLT (with off-hook preference): Enter: [01], [3], [GG], [HOLD] GG = Line Group Number (00-23)...
Page 159
Flexible Button Assignment2-133 Chapter 2 - Features and Operation 8-BUTTON DEFAULT Use Flash 50 programming when you want to modify a range of stations’ attributes using fixed station numbers. Use Flash 51 programming to modify a single station’s attributes using a flexible station number. Programming Steps 1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of the following messages displays: 2. Enter the range of fixed station numbers (100-131) to be...
Page 160
2-134Flexible Button Assignment Chapter 2 - Features and Operation 4. Press button #20. The display updates to reflect current programming for Page B. 5. Press the BUTTON ASSIGN flexible button (Button #11). The following message displays: 6. Enter a valid button number [01-24] to program, followed by the desired button function: [0] = Flexible/user changeable [1] = CO line [2] = Loop button/all-purpose CO appearance [3] = Pool for specific groups [4] = Direct feature programmable (for DSS/BLF, use [4] +...