Have a look at the manual Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
PERCEPTION,,,, LCR/TR PROGRAMMING GUIDE MARCH 1991 ACTALL RN001 Local calls are routed according to NONE Route Table #l (see AOCNOOl). RN002 312 +---- Metro area calls are routed RN003 according to Route Table #2. 217 309 618 815 ‘----- Calls to Illinois are routed RN004 NONE according to Route Table #3. RN005 NONE RN006 NONE RN007 NONE RN008 NONE RN009 NONE RN010 NONE RN011 NONE RN012 NONE RN013 NONE All calls to these Area Codes are routed RN014 according to Route Table 815. NONE RN015 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 218 219 300 301 302 303 304 305 306 307 308 310 311 313 314 315 316 317 318 319 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 619 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 816 817 818 819 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 REQ PLCR (ACTALL) Printout -17-
PERCEPTIONeh, LCR/TR PROGRAMMING GUIDE MARCH 1991 TN001 AC RN0 oc REQ AOCNOOl 312 01 .---- Local calls (Office Codes below) are routed according to Route Table 81 223 232 244 249 258 289 331 333 336 356 362 367 371 381 382 426 428 433 458 464 466 479 526 534 540 546 552 554 556 557 563 584 587 594 623 634 658 662 669 672 680 683 689 695 697 741 742 746 830 83-l 840 844 851 859 879 888 892 896 946 972 PLCR (AOCNOOl) Printout RTOl RN001 RTl 00 01 RT2 03 01 RT3 NONE NONE RT4 NONE NONE RT5 NONE NONE RT6 NONE NONE SCHA 0000 2400 LC3 RTl LC2 NONE LCl RT2 SCHB 2400 2400 LC3 NONE LC2 NONE LCl NONE SCHC 2400 0000 LC3 NONE LC2 NONE LCl NONE + - - - - Trunk Group 00, Modify Digits Table 0 7. + - - - - Trunk Group 03, Modify Digits Table 0 1. l - - - - Schedule A only used in this application. + - - - - Route 2 can only be used by LCR class #l. + - - - - SCHB prompt must be completed. REQ
PEFiCEPTION,h,, LCR/TR PROGRAMMING GUIDE MARCH 1991 RT02 RN002 RTl 01 01 RT2 03 01 RT3 NONE NONE RT4 NONE NONE RT5 NONE NONE RT6 NONE NONE SCHA 0000 2400 LC3 RTl LC2 NONE LCl RT2 SCHB 2400 2400 LC3 NONE LC2 NONE LCi NONE SCHC 2400 0000 LC3 NONE LC2 NONE LCl NONE REQ Route Table #2 Printout PLCR (RT02) RT03 RN003 RTl 02 01 RT2 04 01 RT3 00 02 RT4 03 02 RT5 NONE NONE RT6 NONE NONE SCHA LC3 LC2 LCl 0800 RTl RT2 RT3 RT4 1800 +- Schedule A = 8 a.m. to 6 p.m. SCHB LC3 LC2 LCl SCHC LC3 LC2 LCl REQ 1800 0800 +- Schedule B = 6 p.m. to 8 a.m. RTl RT3 RT2 RT4 0800 0800 NONE NONE NONE Route Table #3 Printout PLCR (RT03) -19-
PERCEPTION,&,, LCf?/TR PROGRAMMING GUIDE MARCH 1991 RT15 RN015 RTl 00 02 RT2 04 01 RT3 03 02 RT4 NONE NONE RT5 NONE NONE RT6 NONE NONE SCHA 0000 2400 LC3 RTl LC2 RT2 LCl RT3 SCHB 2400 2400 LC3 NONE LC2 NONE LCl NONE SCHC 2400 0000 LC3 NONE LC2 NONE LCl NONE REQ Route Table #I5 Printout PLCR (RT15) REQ MDT1 TN001 DLT NONE I ADD *1 +--------- I -second pause. REQ MDT2 TN002 DLT ADD REQ ~~~;00000*36543~-~~ Modify Digits Table Printout PLCR (MDT1 and MDTP) NOTE: A 1 -second pause is usually required when using Loop Start trunks, to allow the CO line enough time to attach a receiving register. This is usually not required for Ground Start trunks. COD OK REQ PAR HAC ICC SPCCl SPCC2 DDP AUTHl AUTH2 REQ PTOL 312 Y I .---r- These parameters are the same as in DLCl/PAR. I 730~0000 NONE I c These parameters are the same as in DMDR. 1 c- J 05 4---- Absorbs the 5-digit authorization code, and prevents it from being printed (SMDR). t 1 NONE PTOL (PAR) Printout -2o-
PERCEPTION,B,, LCR/TR PROGRAMMING GUIDE MARCH 1991 TYPE CNO OPR INT LDA ACT ACD OCT OCD TYPE SAV REQ > COD OK REQ ARC A OFC A REQ CHG CLS 0 N *------- Operator calls not allowed. 1 N *------- International calls not allowed. r N f------- 555 calls not allowed. D D N PTOL CLSCNO NONE +---------I No Area Codes allowed. 1 NONE 4--------- No Office Codes (local) allowed. (Internal calls only) DTDL (CLS) - PTDL (CLSCNO) Restriction Class #O Printout NOTE: Stations can be programmed for internal calls only by denying LC3 and DTA in the Class of Service Data Block (DCOS). However, this will not deny Operator/International/555 calls. To specifically allow/deny these calls, use the DTOL Data Block. -21-
PERCEPTION,h,, LCR/TR PROGRAMMING GUIDE MARCH 1991 > COD OK REQ TYPE CNO OPR INT LDA ACT ACD OCT OCD TYPE SAV > COD OK REQ CLSCNl DTOL CHG CLS A N Ji PTOL ARC A NONE OFC A TN0 ARC CNO OFC 2009 2909 3809 4709 5609 6509 1409 8309 9209 02 714 1 7300 REQ 2109 2209 2309 2409 2509 2609 2709 3009 3109 3209 3309 3409 3509 3609 3909 4009 4109 4209 4309 4409 4509 4809 4909 5009 5109 5209 5309 5409 5709 5809 5909 6009 6109 6209 6309 6609 6709 6809 6909 7009 7109 7209 7509 7609 7709 7809 7909 8009 8109 8409 8509 8609 8709 8809 8909 9009 9309 9409 9509 9609 9709 9809 9909 2809 3709 4609 5509 6409 7309 8209 9109 DTDL (CLS) - PTOL (CLSCNl) Restriction Class #1 Printout c -22-
PERCEPTION,&,, LCR/TR PROGRAMMING GUIDE MARCH 1991 CNO OPR INT LDA ACT ACD OCT OCD TYPE SAV > COD OK REQ CLSCN2 ARC A OFC A TN0 ARC CNO OFC A N PTOL 217 815 2009 2909 3809 4709 5609 6509 7409 8309 9209 01 714 L 7300 (See Note) 219 309 312 317 414 608 618 715 812 2109 2209 2309 2409 2509 2609 2709 3009 3109 3209 3309 3409 3509 3609 3909 4009 4109 4209 4309 4409 4509 4809 4909 5009 5109 5209 5309 5409 5709 5809 5909 6009 6109 6209 6309 6609 6709 6809 6909 7009 7109 7209 7509 7609 7709 7809 7909 8009 8109 8409 8509 8609 8709 8809 8909 9009 9309 9409 9509 9609 9709 9809 9909 2809 3709 4609 5509 6409 7309 8209 9109 REQ Allows all calls to Illinois, Wisconsin, and Indiana, including local and metro calls. No other calls allowed, except (714) 730-XxXx. DTDL (CLS) - PTOL (CLSCN2) Restriction Class #2 Printout Note: The add/delete list is not shown here. Instead, the result of the programming is shown by using the PTOL Program. -23-
PERCEPTION,&, LCR/lR PROGRAMMING GUIDE MARCH 1991 COD OK DTOL REQ CHG TYPE CNO OPR INT LDA ACT ACD OCT OCD CLS 3 Y Y Y A A TYPE SAV N > COD OK PTOL REQ CLSCN3 ARC A OFC A REQ 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 7.0 0 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 2009 2909 3809 4709 5609 6509 7409 8309 9209 2109 3009 3909 4809 5709 6609 7509 8409 9309 2209 3109 4009 4909 5809 6709 7609 8509 9409 2309 2409 2509 2609 2709 2809 3209 3309 3409 3509 3609 3709 4109 4209 4309 4409 4509 4609 5009 5109 5209 5309 5409 5509 5909 6009 6109 6209 6309 6409 6809 6909 7009 7109 7209 7309 7709 7809 7909 8009 8109 8209 8609 8709 8809 8909 9009 9109 9509 9609 9709 9809 9909 There are no restrictions-treated as if TOL = NONE. c OTOL (,CLS) - PTOL (CLSCNS) Restriction Class #3 Printout -24-
LCR/TR PROGRAMMING GUIDE MARCH 1991 7. LOGIC 7.02 All of the LCR/TR logic, and the sequence in which the logic is processed by the CPU, are 7.00 General summarized in the Detailed Logic Flowchart. Use this flowchart to answer questions about how the 7.01 The purpose of the General Logic Flowchart system will act when programmed in a certain way. (which begins below) is to show the general flow for The flowchart may also be used as a fault finding aid a typical LCR phone call, but without the details. for customer data. GENERAL LOGIC FLOWCHART Station user dials Start here for To// Restriction. NOTE: See To// Restriction classificafion table (DTOUCLS). See area/office code exception table (if programmed) for this area code NO office code an
PERCEPTION,h,, LCR/TR PROGRAMMING GUIDE MARCH 1991 GENERAL LOGIC FLOWCHART (continued) NOTE: See DLCVAOC - - - tables TN01 - 16. See route table number selected - See modify digits table number _ indicated by the RTB. The route table selects an idle trunk --- according to time of day and station LCR Digits are deleted and/or added to --- dialed number. From NOTE: Least Cost Routing - - - - - LCR access code was dialed. Y I I YES Select the route table number (RN0 XX) from the appro riate AOC ta I! le. Number is dialed and call progress tones are heard. i A END 1 \. . . -26-