Page 41
76-110-0887/0, Issue 1 3-16 Carry out the postinstallation checks described in Section 3.17 to Section 3.19 of this manual. Program a series of unite features, which are necessary in order for emaGEN to operate, following the programming instructions in Section 19 of this manual. WARNING You should install an AC surge protector to protect the emaGEN-PC against power fluctuations. Install the surge protector before setup and test procedures are car- ried out. Use of a UPS is also recom-...
Page 42
Section 3: INSTALLATION 3-17 Use modular line cords between the single-line set connections and the ports, then bundle and secure the modular cords. Use a marker to write the extension number assigned to the port number on the modular cords. Depending on the type of telephone system, and whether or not the system is integrated, the method of connecting with the telephone system varies. More information on integration may be found in the PBX chapter. 3.13 PBX SOFTWARE CONSIDERATIONS emaGEN...
Page 43
76-110-0887/0, Issue 1 3-18 3.14 INSTALLING THE emaGEN SYSTEM Use the following procedure to install the equipment: 1. Inspect the shipping cartons for signs of damage. The Carrier is responsible for any damage caused during shipment and should provide the distributor with information needed to file a damage report. Once the claim has been filed, the item or items will then be repaired or replaced. 2. Carefully open each carton and remove the content. Check the equipment against the packing...
Page 44
Section 3: INSTALLATION 3-19 2. Walk through Site Parameters and enter appropriate informa- tion. 3. Enter Port Definition and configure the lines as needed. 4. Walk through PBX Parameters and integrate emaGEN with the local PBX. 5. If there are several departments in the particular installation, define them in Department definition. 6. Set the classes of service according to the customer’s needs. 7. Open mailboxes. 3.16 CHECKLIST After completing the installation process, including the PBX section,...
Page 45
76-110-0887/0, Issue 1 3-20 3.17 CHECKING CABLING After completing hardware installation, check all the wiring and cables for integrity and secure connections. Particular attention should be paid to the following items: The audio connections between: each emaGEN-PC voice mail card and the audio junction box; the audio junction box and the MDF. The data cabling between the emaGEN-PC voice mail card and the OCD card. That all the connections to the unite system cabinet are firmly in...
Page 46
Section 3: INSTALLATION 3-21 3.20emaGEN SYSTEM DETAILED INSTALLATION INSTRUCTIONS 3.20.1emaGEN Voice Mail full installation -- version 9 NOTE Commands you need to type are shown in bold. Connect to the system with the following FTP command and paste the installation file (t3install.tgz) to the directory. FTP://root:tenecs@[system_ip] Connect to the system with the Telnet command -- or locally with the terminal windows. Telnet [system_ip] emaGEN login: tenecs Password: tenecs Last login:Sun...
Page 47
76-110-0887/0, Issue 1 3-22 Enter password for user t3adm.tenecs New password:tenecs Bad password: too simple Re-enter new password:tenecs Password changed. Configure postgres database (Y/N)?:y Import vmsys database (Y/N)?:y This will erase the old data. Are you sure (Y/N)?:y Import default registry (Y/N)?:y Install a1.exe file (Y/N)?:n Do you want to install other languages (Y/N)?:y Install Hebrew (Y/N)?:y Install extra stuff (Y/N)?:y \jsdk/....... Install/Remove modem card. 1....
Page 48
Section 3: INSTALLATION 3-23 2. Add a modem. 3. Remove a modem. 4. List availiable modems. q. Finish with hylafax configuration. >1 Setup program for HylaFAX (tm)4.1. No scheduler config file exists,creating one from scratch. Country code [1]?[enter] Area code []? 3 Long distance dialing prefix [1]? [enter] International dialing prefix [011]? [enter] Dial string rules file (relative to /var/spool/hylafax) [etc/dialrules]?[enter] Tracing during normal server operation [1]?[enter] Default tracing...
Page 49
76-110-0887/0, Issue 1 3-24 Are these ok [yes]?Ye s Creating new configuration file /var/spool/hylafax/etc/config... Hylafax configuration. 1. Run fax setup. 2. Add a modem. 3. Remove a modem. 4. List availiable modems. q. Finish with hylafax configuration. >2 Enter device (ttyXXX):ttyS3 (modem in com4 define ttyS1 for modem in com1) Country code [1]?[enter] Area code [415]?[enter] Phone number of fax modem [+1.999.555.1212]?[enter] Local identification string (for...
Page 50
Section 3: INSTALLATION 3-25 to /var/spool/hylafax)[]?[enter] Tag line font file (relative to /var/spool/hylafax) [etc/lutRS18.pcf]?[enter] Tag line format string [From %%l|%c|Page %%P of %%T]?[enter] Time before purging a stale UUCP lock file (secs)[30]?[enter] Hold UUCP lockfile during inbound data calls [Yes]?[enter] Hold UUCP lockfile during inbound voice calls [Yes]?[enter] Percent good lines to accept during copy quality checking [95]?[enter] Max consecutive bad lines to accept during...