Page 21

76-110-0887/0, Issue 1
2-4
 The user of a unite system Avanti 3025, Avanti 3020 and Avanti 
3015D telephone set or Executive set with expanded display can 
view a list of incoming outside calls, provided that the Central 
Office supports Caller ID for those calls. These calls are differen-
tiated between those that were answered and those that were 
not answered. The user can toggle between a display of the 
caller’s name or the caller’s number. If the user is authorized to 
enter the mailbox of another...

Page 22

Section 2:  SYSTEM OVERVIEW
2-5
NOTE
emaGEN is a versatile system with many
programmable variations. Unless otherwise
specified, this manual presents the default
operation and settings of programmable
features and parameters.
2.3emaGEN SYSTEM HARDWARE
2.3.1 The emaGEN-PC
The 
emaGEN system is based on a dedicated personal computer, 
termed the 
emaGEN-PC, fitted with additional printed circuit cards, 
as required for full operation of the purchased system.
2.3.2 The 
emaGEN Voice Mail cards
emaGEN can be...

Page 23

76-110-0887/0, Issue 1
2-6
2.3.3 OCD cards in the system cabinet
emaGEN can be configured with up to 28 voice mail ports, in all 
unite systems.
The required audio and data connections are made between 
ema-
GEN
 card(s) in the emaGEN-PC and OCD card(s) in the unite 
system cabinet. These connections consist of:
 Data connection: from the 
emaGEN-PC com port, via a three-
wire cable to the RJ45 connector on the outside end of the first 
OCD card holding MIMs. A similar cable must be connected to a...

Page 24

Section 2:  SYSTEM OVERVIEW
2-7
Figure 2-1     emaGEN connections with the unite system
2.4emaGEN SYSTEM MENU FEATURE OVERVIEW
Figures 2-2 and 2-3, below, present overviews of emaGEN Opera-
tion features and Administration features menu processing, respec-
tively. Refer to these figures, as necessary, to follow the 
emaGEN 
processing flow and see the features involved.
Knowing the capabilities of each 
emaGEN feature is the key to ob-
taining the maximum amount of service and benefit to your organiza-...

Page 25

76-110-0887/0, Issue 1
2-8
Figure 2-2        emaGEN Operation Menu feature overview
Figure 2-3        
emaGEN Administration Menu feature overview
1/7/8   	
  
  
     2/5     

 
     
    
   
  
 1     2  3       4     5  6
3! 
  
	
  1#   2	 3$#  4%  
  5...

Page 26

3-1
Section 3 
INSTALLATION
3.1 GENERAL
Sections 3.2 through Section 3.6, below, describe planning and 
component requirements for the installation of the 
emaGEN sys-
tem, .
Section 3.7 through Section 3.16, below, describe the procedure  for 
installing the physical components of 
emaGEN within the ema-
GEN
-PC, and the connections between the emaGEN-PC and the 
unite system.
Section 3.17 through Section 3.21, below, describe post-installation 
checkout and troubleshooting procedures for 
emaGEN.
3.2...

Page 27

76-110-0887/0, Issue 1
3-2
unite system programming for emaGEN, as described in Sec-
tion 19, below, utilizing the 
unite emanager.
3.3 INSTALLATION PREPARATIONS
3.3.1 Reading the documentation
Prior to setting up the 
emaGEN system, read through this manual 
and familiarize yourself with its content and the system compo-
nents.
3.3.2
emaGEN-PC printed circuit cards
The 
emaGEN-PC must be fitted with emaGEN printed circuit 
cards, depending on the number of 
emaGEN ports you wish to 
establish in your...

Page 28

Section 3:  INSTALLATION
3-3
The unite system configuration must include at least one OCD 
card for use with 
emaGEN. unite system configuration must 
include:
 a second OCD card, if the 
emaGEN system includes more 
than 12 
emaGEN voice mail ports;
 a second and third OCD cards, if the 
emaGEN system 
includes more than 24 
emaGEN voice mail ports.
Each OCD card must be equipped with an MIM for each group of 
four 
emaGEN ports to be connected to the card. Since only three 
MIMs can be installed on...

Page 29

76-110-0887/0, Issue 1
3-4
NOTE
In order to assure proper functioning of the
Speech Recognition feature, it is recom-
mended that adequate memory be installed
in the 
emaGEN-PC. 
128 MB memory should be added to an
emaGEN-PC with an initial memory of 128
MB, for every four additional voice ports
installed in the system -- when upgrading
from the initial four voice ports.
3.4.2 Communication requirements programming
The baud rate for all system elements must be programmed as 
9600 bps. 
3.5 CRITICAL...

Page 30

Section 3:  INSTALLATION
3-5
3.6.2 Audio cable(s) from the emaGEN-PC to the OCD card(s)
You must connect each 
emaGEN-PC card to an OCD card by 
means of two audio cables, as described below and more fully in 
Section 3.9.4, below.
This connection is by means of:
 Two two-pair cables from the 
emaGEN-PC card to the junction 
box.
  A pair of wires from each junction box terminal pair to 
 the MDF audio terminals corresponding to each 
emaGEN port 
voice channel. 
 A standard 25-pair cable from the MDF...