Home
>
Telrad Digital
>
Communications System
>
Telrad Digital Emagen Unified Messaging System Manual
Telrad Digital Emagen Unified Messaging System Manual
Here you can view all the pages of manual Telrad Digital Emagen Unified Messaging System Manual. The Telrad Digital manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
76-110-0887/0, Issue 1 2-4 The user of a unite system Avanti 3025, Avanti 3020 and Avanti 3015D telephone set or Executive set with expanded display can view a list of incoming outside calls, provided that the Central Office supports Caller ID for those calls. These calls are differen- tiated between those that were answered and those that were not answered. The user can toggle between a display of the caller’s name or the caller’s number. If the user is authorized to enter the mailbox of another...
Page 22
Section 2: SYSTEM OVERVIEW 2-5 NOTE emaGEN is a versatile system with many programmable variations. Unless otherwise specified, this manual presents the default operation and settings of programmable features and parameters. 2.3emaGEN SYSTEM HARDWARE 2.3.1 The emaGEN-PC The emaGEN system is based on a dedicated personal computer, termed the emaGEN-PC, fitted with additional printed circuit cards, as required for full operation of the purchased system. 2.3.2 The emaGEN Voice Mail cards emaGEN can be...
Page 23
76-110-0887/0, Issue 1 2-6 2.3.3 OCD cards in the system cabinet emaGEN can be configured with up to 28 voice mail ports, in all unite systems. The required audio and data connections are made between ema- GEN card(s) in the emaGEN-PC and OCD card(s) in the unite system cabinet. These connections consist of: Data connection: from the emaGEN-PC com port, via a three- wire cable to the RJ45 connector on the outside end of the first OCD card holding MIMs. A similar cable must be connected to a...
Page 24
Section 2: SYSTEM OVERVIEW 2-7 Figure 2-1 emaGEN connections with the unite system 2.4emaGEN SYSTEM MENU FEATURE OVERVIEW Figures 2-2 and 2-3, below, present overviews of emaGEN Opera- tion features and Administration features menu processing, respec- tively. Refer to these figures, as necessary, to follow the emaGEN processing flow and see the features involved. Knowing the capabilities of each emaGEN feature is the key to ob- taining the maximum amount of service and benefit to your organiza-...
Page 25
76-110-0887/0, Issue 1 2-8 Figure 2-2 emaGEN Operation Menu feature overview Figure 2-3 emaGEN Administration Menu feature overview 1/7/8 2/5 1 2 3 4 5 6 3! 1# 2 3$# 4% 5...
Page 26
3-1 Section 3 INSTALLATION 3.1 GENERAL Sections 3.2 through Section 3.6, below, describe planning and component requirements for the installation of the emaGEN sys- tem, . Section 3.7 through Section 3.16, below, describe the procedure for installing the physical components of emaGEN within the ema- GEN -PC, and the connections between the emaGEN-PC and the unite system. Section 3.17 through Section 3.21, below, describe post-installation checkout and troubleshooting procedures for emaGEN. 3.2...
Page 27
76-110-0887/0, Issue 1 3-2 unite system programming for emaGEN, as described in Sec- tion 19, below, utilizing the unite emanager. 3.3 INSTALLATION PREPARATIONS 3.3.1 Reading the documentation Prior to setting up the emaGEN system, read through this manual and familiarize yourself with its content and the system compo- nents. 3.3.2 emaGEN-PC printed circuit cards The emaGEN-PC must be fitted with emaGEN printed circuit cards, depending on the number of emaGEN ports you wish to establish in your...
Page 28
Section 3: INSTALLATION 3-3 The unite system configuration must include at least one OCD card for use with emaGEN. unite system configuration must include: a second OCD card, if the emaGEN system includes more than 12 emaGEN voice mail ports; a second and third OCD cards, if the emaGEN system includes more than 24 emaGEN voice mail ports. Each OCD card must be equipped with an MIM for each group of four emaGEN ports to be connected to the card. Since only three MIMs can be installed on...
Page 29
76-110-0887/0, Issue 1 3-4 NOTE In order to assure proper functioning of the Speech Recognition feature, it is recom- mended that adequate memory be installed in the emaGEN-PC. 128 MB memory should be added to an emaGEN-PC with an initial memory of 128 MB, for every four additional voice ports installed in the system -- when upgrading from the initial four voice ports. 3.4.2 Communication requirements programming The baud rate for all system elements must be programmed as 9600 bps. 3.5 CRITICAL...
Page 30
Section 3: INSTALLATION 3-5 3.6.2 Audio cable(s) from the emaGEN-PC to the OCD card(s) You must connect each emaGEN-PC card to an OCD card by means of two audio cables, as described below and more fully in Section 3.9.4, below. This connection is by means of: Two two-pair cables from the emaGEN-PC card to the junction box. A pair of wires from each junction box terminal pair to the MDF audio terminals corresponding to each emaGEN port voice channel. A standard 25-pair cable from the MDF...