Page 31
76-110-0887/0, Issue 1 3-6 emaGEN, on one, two or three OCD cards; inserting the OCD card(s), with MIM(s) mounted, in the unite system cabinet. Connection between emaGEN and the unite system; Section 3.9.3 and Section 3.9.4, below, describe: making the data connections between: -- the first and, if present, fourth or last, emaGEN-PC card -- and the OCD card(s) in the unite system cabinet; making the audio connection between: -- each emaGEN card in the emaGEN-PC -- and the OCD block in...
Page 32
Section 3: INSTALLATION 3-7 Table 3-1 I/O port jumper settings 3.8.2 emaGEN-PC voice mail card insertion You must insert the emaGEN-PC cards into the emaGEN-PC. Cards can be placed in any PCI slot. WARNING Turn off and disconnect power to the PC, before starting any card insertion proce- dure. The physical act of installation is the same as for any other PC card. This procedure is not described here, since it may vary from one PC model to another. Refer to your PC manual for card installation...
Page 33
76-110-0887/0, Issue 1 3-8 Figure 3-1 Wrist strap guarding against electrostatic discharge 3.9 SYSTEM PREPARATION AND CONNECTIONS TO emaGEN 3.9.1 Mounting an MIM on an OCD card Figure 3-2, below, shows the three module positions on the OCD card. Each OCD card can accommodate up to three cartridge mod- ules, each serving a special option function. You must connect one MIM (multiple interface module) on the OCD card for each group of four emaGEN ports to be connected to the card. The MIM connects...
Page 34
Section 3: INSTALLATION 3-9 2. You then assign voice channel and DN numbers to the ema- GEN ports. 3. Lastly, you physically connect emaGEN-PC cards, via the audio cable, junction box, and MDF, to the audio channels of the OCD card MIM(s). To mount the MIM on the OCD card, perform the following steps, as shown in Figure 3-2, below: 1. Place the OCD card on a soft, clean surface (a piece of sponge or cardboard) with the components facing up. 2. Select the position in which the MIM is to be...
Page 35
76-110-0887/0, Issue 1 3-10 Figure 3-2 Inserting the MIM on the OCD card 3.9.2 Inserting an OCD card into the system cabinet To insert an OCD card in one of the unite system cabinet slots, perform the following steps, as shown in Figure 3-3, below: 1. With the two plastic extension tabs on the end of the OCD card extended outwards, slide the card into the guide runners of the selected slot. 2. Carefully fit the card into the V-shaped insertion guides. 3. Ensure that the female connector on the card...
Page 36
Section 3: INSTALLATION 3-11 Figure 3-3 OCD card insertion 3.9.3 Completing the data connection The first emaGEN card in the emaGEN-PC connects, as described below, directly to the OCD card in the unite system cab- inet, by means of the RJ45 connector located at the end of the OCD card. If two, or more, emaGEN-PC cards are installed, you connect only the first emaGEN-PC card, card number 1, to the OCD card. If four, or more, emaGEN-PC cards are installed, you must connect the fourth, or...
Page 37
76-110-0887/0, Issue 1 3-12 The emaGEN-PC card connection to the OCD card is by means of a cable, shown in Figure 3-4 terminated by: A 9-pin D-type female connector on the emaGEN-PC com port; An RJ45 male connector on the OCD card end of the cable. Figure 3-4 Data cable from emaGEN card to OCD card The wire functions and connections for the emaGEN-PC card to the OCD card data cable are shown in Table 3-1. Table 3-2 Connections of data cable from emaGEN-PC card to OCD card 3.9.4...
Page 38
Section 3: INSTALLATION 3-13 Figure 3-5 emaGEN cabling from emaGEN-PC to OCD card Note in the Figure 3-5, that: Connector J3 on the emaGEN-PC card connects to the OCD card containing the MIM by means of a cable, shown in Figure 3- 6, terminated by an RJ11 connector on both ends. Each of the terminal pairs in the junction box is connected, via a pair of wires, as shown in Figure 3-6, to the audio terminals in the MDF of the corresponding voice channel utilized as an ema- GEN port. A standard...
Page 39
76-110-0887/0, Issue 1 3-14 The wire functions and connections for the audio cable from the emaGEN-PC card to a junction box, and from that junction box to the MDF, are shown in Figure 3-6. For a detailed description of the unite system cabinet to MDF connections, refer to the unite family of systems Installation manual. . Figure 3-6 Audio cable from emaGEN-PC voice mail card to four port junction box Figure 3-7, below, shows the numbers and colors of each pin of the 25-pair cable connector from...
Page 40
Section 3: INSTALLATION 3-15 Figure 3-7 Typical 25-pair cable connector from OCD block in MDF 3.10 ADDITIONAL STEPS BEFORE ACTIVATING emaGEN Although you have made all the required physical connections between the emaGEN-PC and the unite system, you are not yet ready to activate emaGEN. You must now carry out the following steps: