    1 Place maintenance test phone 
    off-hook. Dial tone returned. 
    2 Dial the Diagncstic Test Access Code. Recall dial tone returned. 
    3 
    4A Dial 1 for tone generator test. None. 
    Dial 00 if all tones are to be tested and 
    verify that all tones returned are un- 
    dis!orted. All tones are returned in the sequence 
    shown in Table 6.01 for two seconds 
    each: test repeats until the main- 
    tenance test phone is placed on-hook 
    or hook flashed. 
    4B 
    Dial the individual test number shown Chosen tone returned until main- If chcsen tono is returned dictoricd. 
    in Table 6.01 if a particular tone is to tenance test phone is placed on-hco!c retry test two moie times. If distortion 
    be tested. or hook-flashed. continues, replace the SMXTG PCB 
    5A If additional 
    tE?SiS or procedures are 
    to be performed, hook-flash the main- 
    tenance test phone and dial the next 
    code (Diagnostic Test Access Code is 
    not redialed). Recall dial tone is returned. 
    56 If no additional tests or procedures are 
    to be performed, placa the main- 
    tenance test phone on-hook. Nono.  iab:a 6.00 Tone Generator Test 
    PCDCECURE VERIFICATION 
    TEST 
    NUMBER 
    00 
    01 
    02 
    03 
    04 
    05 
    06 
    07 
    08 
    09 
    10 
    11 
    12 
    13 
    14 
    15 
    16 
    17 
    18 
    19 
    20 
    21 
    22 
    23 
    24 
    25 
    26 
    27 IF VERIFICATION 
    IS NOT OBTAINED s 
    If any tone(s) is returned distortad retry 
    test two mere times. If distortion con- 
    tinues, replace the SMXTG PCB. Ncto 
    that the first 16 tones are hardware in- 
    terrupted. if continuous tones are 
    returned, replace the SMXTG PCB. 
    Table 6.01 Tone Generator Test Numbers 
    TONE 
    Circular Sequence 
    DTMF-1 (697Hz + 1209Hz) 
    DTMF-2 (6Q7Hz + 1336Hz) 
    DTMF-3 (697Hz + 1477Hz) 
    DTMF-4 (77OHz + 1209Hz) 
    DTMF-5 (77OHz + 1336Hz) 
    DTMF-6 (77OHz + 14i7Hz) 
    DTMF-7 (852Hz + 1209Hz) 
    DTMF-8 (852Hz + 1336Hz) 
    DTMF-9 (852Hz + 1477H.z) 
    DTMF-0 (941Hz + 133SHz) 
    DTMF-’ (941Hz + 1209Hz) 
    DTMF-# (941Hz + 14i7Hz) 
    DTMF-A (697Hz + 1633Hz) 
    DTMF-B (770Hz + 1633Hz) 
    DTMF-C (852Hz + 1633Hz) 
    DTMF-D (941Hz -I- 1633Hz) 
    Dial Tone (35OHz + 440Hz) 
    Busy Tone (480Hz +620 Hz) 
    Reorder Tone (Fast Busy Tone) 
    Test Tone (1004Hz @-16dEim) 
    Low Tone (440Hz) 
    Audible Ring (440Hz + 480Hz - uninterrupted) 
    Intercept Tone (440Hz + 620Hz) 
    LDN Call Identification Tone (400 Hz + 480 Hz - interrupted) 
    Called Party Tone (2100 Hz - uninterrupted) 
    Remote Hold Recall Identification Tone (400 Hz) 
    Quiet Tone 
    --_ 
    G-13  
    						
    							I 
    SATURN IIE EPABX A30808-X5130-B120-l-8928 
    Installation Test Procedures Issue 1, May 1986 
    STEP PROCECURE VEFHFICATION 
    1 
    5 
    6A 
    68 Table 6.02 DTMF Receiver Test 
    Place maintenance test phone 
    off-hook. 
    Dial the Diagnostic Test Access Code. 
    Dial # for DTMF receiver test. 
    Dial the four-digit PEN number of the 
    DTMF receiver circuit to be tested. 
    Depress the maintenance test phone 
    keypad’s buttons in the following se- 
    quence. Test tone (1004Hz at -16dBm) 
    returned. 
    a) For 12-button phones: 1, 2, 3, 
    4, 5, 6, 7, 8, 9, 0, *and #. 
    b) For 16-button phones: A, B, C, 
    D, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, * , 
    and #. 
    If additional tests or procedures are 
    to be performed, hook-flash main- 
    tenance tes? phone and dial the next 
    code (Diagnostic Test Access Code is 
    not redialed). Recall dial tone is returned and the 
    associaied DTMF receiver circuit LED 
    in the DTMF PCB is extinguished. 
    If no additional tests or procedures are The associated DTMF receiver circuit 
    to be performed, place the main- LED in the DTMF PCB is extin- 
    tenance test phone on-hook. guished.  Dial tone is returned. 
    Recall dial tone is returned. 
    None. 
    Dial tone returned and the associat- 
    ed DTMF receiver circuit LED in the 
    DTMF PCB is lit steadily. IF VERIFICATION 
    IS NOT OBTAINED 
    If busy tone is returned, the DTMF 
    receiver circuit is busy. Retry later. If 
    intercept tone is returned, the DTMF 
    receiver circuit is not assigned (check 
    data base assignment). 
    If intercept tone is returned at any 
    time, either the DTMF receiver or the 
    maintenance phone’s key-pad is nc? 
    operating properly, or the buttons 
    were depressed in the wrong se- 
    quence. Retry test with another DTMF 
    phone. If intercept tone is returned 
    again, replace the DTMF receiver 
    circuit. 
    Table 6.03 Station Line Test 
    NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the station under test is c!assmarked 
    with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Diagnos- 
    tic Test routines; therefore, perform only steps 5 through 10. 
    2) If the system option flag TSTDIAG has been disabled in the data base or the station under test is not classmarked 
    with the TSTAPP feature, the maintenance test phone is required to enable or disable the Apparatus Diagnostic 
    Test routines; therefore, oerform the entire procedure (steps 1 throuqh 11). 
    STEP 
    . 
    PROCEDURE VERIFICATION 
    Place maintenance test phone 
    off-hook. Dial tone is returned. 
    Dial the Diagnostic Test Access Code. 
    Dial 3 to enable the Apparatus tests. 
    Place the maintenance test phone 
    on-hook. Recall dial tone is returned. 
    Confirmation tone is returned. 
    None. 
    Place the station under test off-hook. Dial tone is returned 
    ;:;ethe Test-Station Line Access Confirmation tone is returned. IF VERIFKATION 
    IS NOT OBTAINED 
    1 
    6-14  
    						
    							SATURN IIE EPABX 
    Installation Test Procedures A30808-X5130-B120-l-8928 
    Issue 1, May 1986 . 
    Tab!c A.03 Station Line Test fCnntinc)edl 
    , STEP 
    PROCEDURE 
    \-----------I 
    STEP FROCEDUZZ VERIFICATTION IF VER!FiCATION 
    IS NOT OBTAINED ’ 
    7 Place station under test on-hook. Ringing returned. 
    If ringing is not heard, switch the sta- 
    tion instrument to determine if it is 
    defective. If ringing is still not heard, 
    replace the associated subscriber line 
    PCB. 
    8 Pick up handset to answer test tail. 
    9 Verify that the test tone level is cor- Test tone (1004Hz @ -lGdBm) is If the returned test tone level is weak, 
    rect by using a TMS. returned. swap the instrument to determine if it 
    is defective If the test tone level in- 
    creases considerably, replace the s:a- 
    tion instrument. If test tone level 
    remains weak, replace the associat- 
    ed subscriber line PCB (SLMA, 
    10 
    Place station under test on-hoo!(. SLA16 or SLMD). 
    None. 
    11 
    If no additional Test routines are to be 
    performed, proceed as follows: 
    Place maintenance test phone Dial tone is returned. 
    off-boo!
    						
    							SATURN IIE EPABX A30808-X5130-B120-l-B928 
    instaliation Test Procedures Issue 1, May 1986 
    Wbtc 6.04 DTMF Pad Test 
    STEP PWO@EDWE VERIFICATION IF VERIFICATIGN 
    IS NOT OBTAINED 
    7 Depress the DTMF keypad buttons in Recall dial tone ceases. After all the If busy tone is returned at any time, 
    the following sequence: DTMFjteypad buttons are depressed either the DTMF key pad buttons were 
    in the sequence indicated, test tone depressed in the wrong sequencethe 
    For 12-button phones: 1, 2, 3, 4, 5, 6, (1004Hz @ -16dBm) is returned for DTMF keypad of the station under test 
    7, 8, 9, 0, 4 and #. one minute. is defective or the subscriber line cir- 
    cuit is defective. 
    For 16-button phones: A, B, C, D, 1, 
    2, 3, 4, 5, 6, 7, 8, 9, 0, * and #. To locate failure, retry test to verify that 
    the keypad buttons were not 
    depressed out of sequence. If 
    problem persists, swap the station in- 
    strument to determine ii it is defective. 
    If problem remains, replace the rp- 
    propriate subscriber line PCB. 
    8 F;Q;he level of test tone by using If the measured test tone is correct 
    but is weak, replace the station set. 
    If the measured tone is low, rep!ace 
    the subscriber line PCB SLMA or 
    SLA16). 
    9 Place DTMF station under test on- None. 
    hook to terminate test. 
    10 If no additional apparatus tests are to 
    be performed, proceed as foilows: 
    Place maintenance test phone Dial tone is returned. 
    off-hoo!(. 
    Dial the Diagnostic Test Access Code. Recall dial tone is returned. 
    Dial 2 to disable the Apparatus Tests. None. 
    Place maintenance test phone None. 
    on-hook. 
    Table 6.05 Console Test 
    NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base, the maintenance test phone is not required 
    to enable and disable the Apparatus Test routines; therefore, perform only steps 5 through 9. 
    2) If the system option flag TSTDIAG has been disabted in the data base, the maintenance test phone is required 
    to enable and disable the Apparatus Test routines; therefore, perform the entire procedure (steps 1 through 10). 
    STEP PROCEDURE VERIFICATION IF VERIFICATION 
    IS NO-i- OBTAINED 
    1 Place maintenance test phone Dial tone is returned. 
    off-hook. 
    2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 
    3 
    Dial 3 to enable the Apparatus Tests. Confirmation tone is returned. 
    4 
    Place maintenance test phone None. 
    on-hook. 
    5 
    At the Console under test dial the At- Recall dial tone is returned. Also the If reorder tone is returned, the Atten- 
    tendant Console Test access code access code is displayed momentar- dant Console Test routine is in use, 
    when the console is in an idle state. ily, then the display changes to CON- retry later. 
    SOLE TEST and all button LEDs are 
    extinguished. 
    6-16  
    						
    							SATURN IIE EPABX A30808-X5130-B120-l-8928 
    Installation Test Procedures Issue 1, May 1986 
    Table 6.05 Console Test (Continued) 
    :TE? PRCCEDURE VERIFICATIDN lF VERlFlCATlON 
    IS NOT OBTAINED + 
    6 Depress the console’s keypad buttons All digits dialed are displayed (ac- If proper verification is not obtained or 
    in the following sequence: 1, 2, 3, 4, cumulate). busy tone is returned at any time, the 
    5, 6, 7, 8, 9, 0, * and #. keypad buttons or console buttons 
    were depressed out of sequence, the 
    7 Depress the console’s feature buttons Each button LED lights when console is defective, or PIMD circuit 
    in the sequence shown in Figure 6.19.’ depressed and extinguishes when the is defective. To isolate the failure, retry 
    next key is depressed. test to verify that the buttons were not 
    depressed out of sequence. 
    a After the last button in the sequence Groups of eight of each of the display- If proper verificaiion is not obtained or 
    is depressed, depress any console able characters are scrolled in the se- busy tone is returned again, replace 
    button to initiate the display test. The quence shown in Table 6.06. Ai-ier the associated PIMD PCB to verify 
    display can be suspended by last character is displayed (under whether the PIMD circuit or the con- 
    depressing any key on the console score character), the display unit is sole is defective. If proper verificaiion 
    and resumed in the same manner. cleared and the following LEDs is obtained, replace the associa?ed 
    momentarily light then extinguish in PIMD PCB. If proper verification is not 
    the following sequence: obiained or busy tone is returned 
    again, replace the console. 
    a) TRUNK GROUP STATUS 1 - 
    b) %“RCE 
    c) DESTINATION 
    d) ALERT 
    e) CW 
    9 MAJ ALM 
    g) MIN ALM 
    After the above indications are com- 
    pleted the fo!lowing indications occur: 
    Ringbeck tone is returned. 
    All LEDs on the display assembly 
    flash.. . 
    After the above indications are com- 
    pleted the following indications occur: 
    Ringback tone is returned. 
    All LEDs on the display assembly 
    flash. 
    The audible alerting device sounds at 
    intervals. 
    REMOVE HANDSET is displayed. 
    9 Remove and reinsert handset assem- INSERT HANDSET is displayed while 
    bly to terminate test, or wait 30 se- handset is removed. After handset is 
    conds for test timeout. reinserted, console returns to normal 
    operation. 
    10 If no additional apparatus tests are to 
    be performed, proceed as follows: 
    Place maintenance test phone Dial tone is returned. 
    off-hook. 
    Dial the Diagnostic Test Access Code. Recall dial tone is returned. 
    Dial 2 to disable the Apparatus Tests. None. 
    Place maintenance test phone None. 
    on-hook. 
    6-17  
    						
    							I 
    - 
    SATURN IIE EPABX 
    A30808-X5130-8120-143928 
    installation Test Procedures 
    Issue 1, May 1986 
    TRUNK GGOUPSTATUS 
    nnnnnnnn k 
    (ALPHANUMERIC DISPLAY LNI;) 
    SOUlxi OESTIXATION 
    00000000 
    li 18 19 20 21 22 23 24 
    ALERT CL1 
    Figure 6.19 Attendant Console Keypad and Feature Button Depression Sequence  
    						
    							SATURN IIE EPABX 
    A30808-X5130-B120-l-6926 
    Installation Test Procedures 
    Issue 1, May 1986 
    Table 6.06 Attendant Console Displayable Characters 
    ORDER 
    1. 
    2. 
    3. 
    4. 
    5. 
    6. 
    7. 
    8. 
    9. 
    10. 
    11. 
    12. 
    13. 
    14. 
    15. 
    16. 
    17. 
    18 19. 
    20. 
    2’:. 
    23: 
    24. 
    25. 
    26. 
    27. 
    28. 
    29.  30. 
    31. 
    32. CHARACTER 
    I I I I I I ! ! 
    ;;;;,A!,;;;; 
    $$$$5$$$ 
    o/o o/o 010 o/o o/o o/o o/o % 
    &&&&&&&& 
    I I I I I I I I 
    ( ( ( ( ( ( ( ( 
    ) 1 1 1 1 1 1 1 
    * l * * * l * * ++++++++ 
    I I > 9 I 1 3  I 
    - - - - - - - - 
    i i i i i i i i 
    00000000 
    1 1 1 1 1 1 1 1 
    22222222 
    33333333 
    44444444 
    55555555  66666666 
    77777777 
    88888888 
    99999999 
    : : : : : : : : 
    ; ; ; ; ; ; ; ; 
    (((((((C 
    TPffSf=>S 
    ???????? 
    OQOQ@@@@ ORDER 
    CHARACTER 
    33. AAAAAAAA 
    34. BBBBBBBB 
    cccccccc 
    ii: DDDDDDDD 
    37. EEEEEEEE 
    FFFFFFFF 
    :i 
    GGGGGGGG 
    40: HHHHHHHH 
    41. I I I I I I I I 
    42. JJJJJJJJ 
    43. 
    K K K K K K I< K 
    44. LLLLLLLL 
    45. MMMMMMMM 
    46. NNNNNNNN 
    47. 00000000 
    48. PPPPPPPP 
    49. QQQQQQQQ 
    50. RRRRRRRR 
    51. ssssssss 
    52. TTTTTTTT 
    54. 53. vvvvvvvv  uuuuuuuu 
    55. wwwwwwww 
    56. xxxxxxxx 
    2; YYYYYYYY 
    zzzzzzzz 
    59: 
    [ I [ 1 I 1 1 I 
    60. 
    61. \\\\))) 
    1 1 I I 62. A A A A ,I> A A A 
    63. 
    ----_--- 
    6-19  
    						
    							I . 
    SATURN IIE EPABX A30808-X5130-B120-I-6928 
    Installation Test Procedures Issue 1, May 1986 
    Table 6.07 Siemcns Digital Telephone - DVAD Dutton Test 
    NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the Siemcns Digital Telephone under 
    test is classmarked with TSTAPP feature, the maintenance test phone is nbt required to enable or disable the 
    Apparatus Diagnostic routines; therefore, perform only steps 5 through 9. 
    2) If the system option flag TSTDIAG has been disabled in the data base or the Siemens Digital Telephone under 
    test is not classmarked with the TSTAPP feature. the maintenance test phone is required to enable or disable 
    the Apparatus Diagnostic routine? 
    s; t herefore, perform the entire procedure (steps 1’ through 10). 
    STEP 
    1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 PROCEDURE . VERIFICATION 
    ‘lace the maintenance test phone 
    ,ff-hook. 
    3ial the Diagnostic Test Access Code. 
    Iial 3 to enable the Apparatus Diag- 
    lostic Tests. 
    ‘lace maintenance test phone 
    x+hook. 
    ‘lace Siemens DYAD Telephone 
    ,ff-hook. 
    Dial the Siemens Digital Telephone 
    rest Access Code. 
    Ieoress the Siemens DYAD Telc- 
    &ne keypad buttons as, fo!lows: 1, 
    3, 3, 4, 5, 6, 7, 8, 9, 0, * , i?. 
    Depress the DYAD feature buttons in 
    the sequence shown in Figure 6.20 
    and according to the Siemens DYAD 
    Telephone model. 
    Place Siemens DYAD Telephone un- Siemens DYAD Telephone returns to 
    der test on-hook to terminate test. normal operation. 
    If no additional Apparatus Diagnostic 
    Test routines are to be performed, pro- 
    ceed as follows: 
    Place maintenance test phone 
    off-hook. Dial tone is returned. 
    Dial the Diagnostic Test Access code. Recall dial tone is returned. 
    Dial 2 to disable the Apparatus Diag- 
    nostic Test. None. 
    Place maintenance test phone on- 
    hook.None. None.  Iial tone is returned. 
    qecall dial tone is returned. 
    >onfirmation tone is returned. 
    Uone. 
    Iial tone is returned. 
    secall dial tone is returned. 
    The access code is momentarily dis- f reorder tone is returned, the Sie- 
    3layed, then the display unit and but- nens DYAD Telephone 
    Button Test is 
    ton LEDs are extinguished. n use, try later. 
    Button LEDs light when depressed 
    and extinguish when the next button 
    is depressed. 
    After the last button is depressed, the 
    following indications occur: 
    Ringback tone is returned. 
    All button LEDs flash. 
    The audible alerting device sounds at 
    intervals. 
    TEST COMPLETE is displayed. IF VERiFICATlON 
    IS NOT OBTAINED 
    f proper verification is not obtained cr 
    xsy tone is returned at eny time, 
    either the keypad buttons cr featuie 
    buttons were depressed out of se- 
    quence, the DYAD Telephone is defac- 
    tive, or the SLMD circuit is defective. 
    To isolate the failure, retry test to veri- 
    fy that the buttons were not depressed 
    Dut of sequence. 
    If proper verification is not obtained or 
    busy tone is returned again, replace 
    the Siemens DYAD Telephone under 
    test with a known good DYAD Tele- 
    phone and retry test. If proper verifi- 
    cation is not obtained or busy tone is 
    returned again, replace the SLMD 
    PCB. 
    I 
    - 
    6-20  
    						
    							I 
    - 
    SATURN HE EPABX 
    Installation Test Procedures A30808-X5130-8120-1-8928 
    Issue 1, May 1986 
    IS BUTTON 
    DYAD 
    26 BUTTON 
    DYAD 
    SEE NOTE 
    NOTE: These buttons do not 
    contain LEDs. 
    SEE NOTE y 
    / ’ 
    I 
    Figure 6.20 Siemens DYAD Telephone Button Depression Sequence 
    6-21  
    						
    							SATURN IIE EPABX 
    Installation Test Procedures A30808-X5130-BlZO-l-8928 
    Issue 1, May 1986 
    Table 6.06 Siemcns Digital Telephone - JR-DYAD Button Test 
    NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the Siemens Digital Telephone under 
    test is classmarked with TSTAPP feature, the maintenance test phone is ‘not required to enable or disable the 
    Apparatus Diagnostic routines; therefore, perform only steps‘5 through 9. 
    2) If the system option flag TSTDIAG has been disabled in the data base or the Siemens Digital Telephone under 
    test is not classmarked with the TSTAPP feature, the maintenance test phone is required to enab!e or disable 
    the Apparatus Diagnostic routines; therefore, perfcrm ihe entire procedure (steps 1 through i0). 
    STEP PROCEDURE VERIFICATION IF VERIFICATION 
    IS NOT OBTAINED 
    1 Place the maintenance test phone Dial tone is returned. 
    off-hook. 
    2 Dial the Diagncstic Test Access Code. Recall dial tone is returned. 
    3 Dial 3 to enable the Apparatus Diag- Confirmation tone is returned. 
    nostic Tests, 
    4 Place maintenance test phone None. 
    on-hook. 
    5 Place JR-DYAD Telephone off-hook. Dial tone is rereturned. 
    6 Dial the Siemens Digital Telephone Recall dial tone is returned. If reorder tone is returned, the Sie- 
    Test Access Code. mens JR-DYAD Telephcne Button Test 
    is in use, try later. 
    7 Depress the Siemens JR-DYAD Tele- Ii proper verification is net obtainsd or 
    phone keypad buttons as, follows: 1, busy tone is returned at any iime, 
    2, 3, 4, 5, 6, 7, 8, 9, 0, * , #. either the keypad buttons or feature 
    buttons were depressed out of se- 
    8 Depress the JR-DYAD feature buttons Button LEDs light when depressed quence, the JR-DYAD Telephone is 
    in the sequence shown in Figure 6.21. and extinguish when the next button defective, or the SLMD circuit is 
    is depressed. defective. To isolate the failure, retry 
    test to verify that the buttons were not 
    After the last button is depressed, the depressed out of sequence. 
    following indications occur: 
    If proper verification is not obtained or 
    Ringbac!c tone is returned. busy tone is returned again, replace 
    All button LEDs flash. the Siemens JR-DYAD Telephone un- 
    der test with a known good JR-DYAD 
    The audible alerting device sounds at Telephone and retry test. If proper 
    intervals. verification is not obtained or busy 
    tone is returned again, the SLMD cir- 
    cuit is defective and the SLMD PC6 
    requires replacement. 
    9 
    Place Siemens JR-DYAD Telephone Siemens JR-DYAD Telephone returns 
    under test on-hook to terminate test. to normal operation. 
    10 If no additional Apparatus Diagnostic 
    Test routines are to be performed, pro- 
    ceed as follows: 
    P&tokmaintenance test phone Dial tone is returned. 
    Dial the Diagnostic Test Access code. Recall dial tone is reiurned. 
    Dial 2 to disable the Apparatus Diag- None. 
    nostic Test. 
    Place maintenance test phone None. 
    on-hook. 
    6-22  
    						