SATURN IIE E?ABX A30808-X5130-8120-l-8928 Installation Test Procedures issue 1, May 1986 TEP 1 Place maintenance test phone off-hook. Dial tone returned. 2 Dial the Diagncstic Test Access Code. Recall dial tone returned. 3 4A Dial 1 for tone generator test. None. Dial 00 if all tones are to be tested and verify that all tones returned are un- dis!orted. All tones are returned in the sequence shown in Table 6.01 for two seconds each: test repeats until the main- tenance test phone is placed on-hook or hook flashed. 4B Dial the individual test number shown Chosen tone returned until main- If chcsen tono is returned dictoricd. in Table 6.01 if a particular tone is to tenance test phone is placed on-hco!c retry test two moie times. If distortion be tested. or hook-flashed. continues, replace the SMXTG PCB 5A If additional tE?SiS or procedures are to be performed, hook-flash the main- tenance test phone and dial the next code (Diagnostic Test Access Code is not redialed). Recall dial tone is returned. 56 If no additional tests or procedures are to be performed, placa the main- tenance test phone on-hook. Nono. iab:a 6.00 Tone Generator Test PCDCECURE VERIFICATION TEST NUMBER 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 IF VERIFICATION IS NOT OBTAINED s If any tone(s) is returned distortad retry test two mere times. If distortion con- tinues, replace the SMXTG PCB. Ncto that the first 16 tones are hardware in- terrupted. if continuous tones are returned, replace the SMXTG PCB. Table 6.01 Tone Generator Test Numbers TONE Circular Sequence DTMF-1 (697Hz + 1209Hz) DTMF-2 (6Q7Hz + 1336Hz) DTMF-3 (697Hz + 1477Hz) DTMF-4 (77OHz + 1209Hz) DTMF-5 (77OHz + 1336Hz) DTMF-6 (77OHz + 14i7Hz) DTMF-7 (852Hz + 1209Hz) DTMF-8 (852Hz + 1336Hz) DTMF-9 (852Hz + 1477H.z) DTMF-0 (941Hz + 133SHz) DTMF-’ (941Hz + 1209Hz) DTMF-# (941Hz + 14i7Hz) DTMF-A (697Hz + 1633Hz) DTMF-B (770Hz + 1633Hz) DTMF-C (852Hz + 1633Hz) DTMF-D (941Hz -I- 1633Hz) Dial Tone (35OHz + 440Hz) Busy Tone (480Hz +620 Hz) Reorder Tone (Fast Busy Tone) Test Tone (1004Hz @-16dEim) Low Tone (440Hz) Audible Ring (440Hz + 480Hz - uninterrupted) Intercept Tone (440Hz + 620Hz) LDN Call Identification Tone (400 Hz + 480 Hz - interrupted) Called Party Tone (2100 Hz - uninterrupted) Remote Hold Recall Identification Tone (400 Hz) Quiet Tone --_ G-13
I SATURN IIE EPABX A30808-X5130-B120-l-8928 Installation Test Procedures Issue 1, May 1986 STEP PROCECURE VEFHFICATION 1 5 6A 68 Table 6.02 DTMF Receiver Test Place maintenance test phone off-hook. Dial the Diagnostic Test Access Code. Dial # for DTMF receiver test. Dial the four-digit PEN number of the DTMF receiver circuit to be tested. Depress the maintenance test phone keypad’s buttons in the following se- quence. Test tone (1004Hz at -16dBm) returned. a) For 12-button phones: 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, *and #. b) For 16-button phones: A, B, C, D, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, * , and #. If additional tests or procedures are to be performed, hook-flash main- tenance tes? phone and dial the next code (Diagnostic Test Access Code is not redialed). Recall dial tone is returned and the associaied DTMF receiver circuit LED in the DTMF PCB is extinguished. If no additional tests or procedures are The associated DTMF receiver circuit to be performed, place the main- LED in the DTMF PCB is extin- tenance test phone on-hook. guished. Dial tone is returned. Recall dial tone is returned. None. Dial tone returned and the associat- ed DTMF receiver circuit LED in the DTMF PCB is lit steadily. IF VERIFICATION IS NOT OBTAINED If busy tone is returned, the DTMF receiver circuit is busy. Retry later. If intercept tone is returned, the DTMF receiver circuit is not assigned (check data base assignment). If intercept tone is returned at any time, either the DTMF receiver or the maintenance phone’s key-pad is nc? operating properly, or the buttons were depressed in the wrong se- quence. Retry test with another DTMF phone. If intercept tone is returned again, replace the DTMF receiver circuit. Table 6.03 Station Line Test NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the station under test is c!assmarked with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Diagnos- tic Test routines; therefore, perform only steps 5 through 10. 2) If the system option flag TSTDIAG has been disabled in the data base or the station under test is not classmarked with the TSTAPP feature, the maintenance test phone is required to enable or disable the Apparatus Diagnostic Test routines; therefore, oerform the entire procedure (steps 1 throuqh 11). STEP . PROCEDURE VERIFICATION Place maintenance test phone off-hook. Dial tone is returned. Dial the Diagnostic Test Access Code. Dial 3 to enable the Apparatus tests. Place the maintenance test phone on-hook. Recall dial tone is returned. Confirmation tone is returned. None. Place the station under test off-hook. Dial tone is returned ;:;ethe Test-Station Line Access Confirmation tone is returned. IF VERIFKATION IS NOT OBTAINED 1 6-14
SATURN IIE EPABX Installation Test Procedures A30808-X5130-B120-l-8928 Issue 1, May 1986 . Tab!c A.03 Station Line Test fCnntinc)edl , STEP PROCEDURE \-----------I STEP FROCEDUZZ VERIFICATTION IF VER!FiCATION IS NOT OBTAINED ’ 7 Place station under test on-hook. Ringing returned. If ringing is not heard, switch the sta- tion instrument to determine if it is defective. If ringing is still not heard, replace the associated subscriber line PCB. 8 Pick up handset to answer test tail. 9 Verify that the test tone level is cor- Test tone (1004Hz @ -lGdBm) is If the returned test tone level is weak, rect by using a TMS. returned. swap the instrument to determine if it is defective If the test tone level in- creases considerably, replace the s:a- tion instrument. If test tone level remains weak, replace the associat- ed subscriber line PCB (SLMA, 10 Place station under test on-hoo!(. SLA16 or SLMD). None. 11 If no additional Test routines are to be performed, proceed as follows: Place maintenance test phone Dial tone is returned. off-boo!
SATURN IIE EPABX A30808-X5130-B120-l-B928 instaliation Test Procedures Issue 1, May 1986 Wbtc 6.04 DTMF Pad Test STEP PWO@EDWE VERIFICATION IF VERIFICATIGN IS NOT OBTAINED 7 Depress the DTMF keypad buttons in Recall dial tone ceases. After all the If busy tone is returned at any time, the following sequence: DTMFjteypad buttons are depressed either the DTMF key pad buttons were in the sequence indicated, test tone depressed in the wrong sequencethe For 12-button phones: 1, 2, 3, 4, 5, 6, (1004Hz @ -16dBm) is returned for DTMF keypad of the station under test 7, 8, 9, 0, 4 and #. one minute. is defective or the subscriber line cir- cuit is defective. For 16-button phones: A, B, C, D, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, * and #. To locate failure, retry test to verify that the keypad buttons were not depressed out of sequence. If problem persists, swap the station in- strument to determine ii it is defective. If problem remains, replace the rp- propriate subscriber line PCB. 8 F;Q;he level of test tone by using If the measured test tone is correct but is weak, replace the station set. If the measured tone is low, rep!ace the subscriber line PCB SLMA or SLA16). 9 Place DTMF station under test on- None. hook to terminate test. 10 If no additional apparatus tests are to be performed, proceed as foilows: Place maintenance test phone Dial tone is returned. off-hoo!(. Dial the Diagnostic Test Access Code. Recall dial tone is returned. Dial 2 to disable the Apparatus Tests. None. Place maintenance test phone None. on-hook. Table 6.05 Console Test NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base, the maintenance test phone is not required to enable and disable the Apparatus Test routines; therefore, perform only steps 5 through 9. 2) If the system option flag TSTDIAG has been disabted in the data base, the maintenance test phone is required to enable and disable the Apparatus Test routines; therefore, perform the entire procedure (steps 1 through 10). STEP PROCEDURE VERIFICATION IF VERIFICATION IS NO-i- OBTAINED 1 Place maintenance test phone Dial tone is returned. off-hook. 2 Dial the Diagnostic Test Access Code. Recall dial tone is returned. 3 Dial 3 to enable the Apparatus Tests. Confirmation tone is returned. 4 Place maintenance test phone None. on-hook. 5 At the Console under test dial the At- Recall dial tone is returned. Also the If reorder tone is returned, the Atten- tendant Console Test access code access code is displayed momentar- dant Console Test routine is in use, when the console is in an idle state. ily, then the display changes to CON- retry later. SOLE TEST and all button LEDs are extinguished. 6-16
SATURN IIE EPABX A30808-X5130-B120-l-8928 Installation Test Procedures Issue 1, May 1986 Table 6.05 Console Test (Continued) :TE? PRCCEDURE VERIFICATIDN lF VERlFlCATlON IS NOT OBTAINED + 6 Depress the console’s keypad buttons All digits dialed are displayed (ac- If proper verification is not obtained or in the following sequence: 1, 2, 3, 4, cumulate). busy tone is returned at any time, the 5, 6, 7, 8, 9, 0, * and #. keypad buttons or console buttons were depressed out of sequence, the 7 Depress the console’s feature buttons Each button LED lights when console is defective, or PIMD circuit in the sequence shown in Figure 6.19.’ depressed and extinguishes when the is defective. To isolate the failure, retry next key is depressed. test to verify that the buttons were not depressed out of sequence. a After the last button in the sequence Groups of eight of each of the display- If proper verificaiion is not obtained or is depressed, depress any console able characters are scrolled in the se- busy tone is returned again, replace button to initiate the display test. The quence shown in Table 6.06. Ai-ier the associated PIMD PCB to verify display can be suspended by last character is displayed (under whether the PIMD circuit or the con- depressing any key on the console score character), the display unit is sole is defective. If proper verificaiion and resumed in the same manner. cleared and the following LEDs is obtained, replace the associa?ed momentarily light then extinguish in PIMD PCB. If proper verification is not the following sequence: obiained or busy tone is returned again, replace the console. a) TRUNK GROUP STATUS 1 - b) %“RCE c) DESTINATION d) ALERT e) CW 9 MAJ ALM g) MIN ALM After the above indications are com- pleted the fo!lowing indications occur: Ringbeck tone is returned. All LEDs on the display assembly flash.. . After the above indications are com- pleted the following indications occur: Ringback tone is returned. All LEDs on the display assembly flash. The audible alerting device sounds at intervals. REMOVE HANDSET is displayed. 9 Remove and reinsert handset assem- INSERT HANDSET is displayed while bly to terminate test, or wait 30 se- handset is removed. After handset is conds for test timeout. reinserted, console returns to normal operation. 10 If no additional apparatus tests are to be performed, proceed as follows: Place maintenance test phone Dial tone is returned. off-hook. Dial the Diagnostic Test Access Code. Recall dial tone is returned. Dial 2 to disable the Apparatus Tests. None. Place maintenance test phone None. on-hook. 6-17
I - SATURN IIE EPABX A30808-X5130-8120-143928 installation Test Procedures Issue 1, May 1986 TRUNK GGOUPSTATUS nnnnnnnn k (ALPHANUMERIC DISPLAY LNI;) SOUlxi OESTIXATION 00000000 li 18 19 20 21 22 23 24 ALERT CL1 Figure 6.19 Attendant Console Keypad and Feature Button Depression Sequence
SATURN IIE EPABX A30808-X5130-B120-l-6926 Installation Test Procedures Issue 1, May 1986 Table 6.06 Attendant Console Displayable Characters ORDER 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18 19. 20. 2’:. 23: 24. 25. 26. 27. 28. 29. 30. 31. 32. CHARACTER I I I I I I ! ! ;;;;,A!,;;;; $$$$5$$$ o/o o/o 010 o/o o/o o/o o/o % &&&&&&&& I I I I I I I I ( ( ( ( ( ( ( ( ) 1 1 1 1 1 1 1 * l * * * l * * ++++++++ I I > 9 I 1 3 I - - - - - - - - i i i i i i i i 00000000 1 1 1 1 1 1 1 1 22222222 33333333 44444444 55555555 66666666 77777777 88888888 99999999 : : : : : : : : ; ; ; ; ; ; ; ; (((((((C TPffSf=>S ???????? OQOQ@@@@ ORDER CHARACTER 33. AAAAAAAA 34. BBBBBBBB cccccccc ii: DDDDDDDD 37. EEEEEEEE FFFFFFFF :i GGGGGGGG 40: HHHHHHHH 41. I I I I I I I I 42. JJJJJJJJ 43. K K K K K K I< K 44. LLLLLLLL 45. MMMMMMMM 46. NNNNNNNN 47. 00000000 48. PPPPPPPP 49. QQQQQQQQ 50. RRRRRRRR 51. ssssssss 52. TTTTTTTT 54. 53. vvvvvvvv uuuuuuuu 55. wwwwwwww 56. xxxxxxxx 2; YYYYYYYY zzzzzzzz 59: [ I [ 1 I 1 1 I 60. 61. \\\\))) 1 1 I I 62. A A A A ,I> A A A 63. ----_--- 6-19
I . SATURN IIE EPABX A30808-X5130-B120-I-6928 Installation Test Procedures Issue 1, May 1986 Table 6.07 Siemcns Digital Telephone - DVAD Dutton Test NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the Siemcns Digital Telephone under test is classmarked with TSTAPP feature, the maintenance test phone is nbt required to enable or disable the Apparatus Diagnostic routines; therefore, perform only steps 5 through 9. 2) If the system option flag TSTDIAG has been disabled in the data base or the Siemens Digital Telephone under test is not classmarked with the TSTAPP feature. the maintenance test phone is required to enable or disable the Apparatus Diagnostic routine? s; t herefore, perform the entire procedure (steps 1’ through 10). STEP 1 2 3 4 5 6 7 8 9 10 PROCEDURE . VERIFICATION ‘lace the maintenance test phone ,ff-hook. 3ial the Diagnostic Test Access Code. Iial 3 to enable the Apparatus Diag- lostic Tests. ‘lace maintenance test phone x+hook. ‘lace Siemens DYAD Telephone ,ff-hook. Dial the Siemens Digital Telephone rest Access Code. Ieoress the Siemens DYAD Telc- &ne keypad buttons as, fo!lows: 1, 3, 3, 4, 5, 6, 7, 8, 9, 0, * , i?. Depress the DYAD feature buttons in the sequence shown in Figure 6.20 and according to the Siemens DYAD Telephone model. Place Siemens DYAD Telephone un- Siemens DYAD Telephone returns to der test on-hook to terminate test. normal operation. If no additional Apparatus Diagnostic Test routines are to be performed, pro- ceed as follows: Place maintenance test phone off-hook. Dial tone is returned. Dial the Diagnostic Test Access code. Recall dial tone is returned. Dial 2 to disable the Apparatus Diag- nostic Test. None. Place maintenance test phone on- hook.None. None. Iial tone is returned. qecall dial tone is returned. >onfirmation tone is returned. Uone. Iial tone is returned. secall dial tone is returned. The access code is momentarily dis- f reorder tone is returned, the Sie- 3layed, then the display unit and but- nens DYAD Telephone Button Test is ton LEDs are extinguished. n use, try later. Button LEDs light when depressed and extinguish when the next button is depressed. After the last button is depressed, the following indications occur: Ringback tone is returned. All button LEDs flash. The audible alerting device sounds at intervals. TEST COMPLETE is displayed. IF VERiFICATlON IS NOT OBTAINED f proper verification is not obtained cr xsy tone is returned at eny time, either the keypad buttons cr featuie buttons were depressed out of se- quence, the DYAD Telephone is defac- tive, or the SLMD circuit is defective. To isolate the failure, retry test to veri- fy that the buttons were not depressed Dut of sequence. If proper verification is not obtained or busy tone is returned again, replace the Siemens DYAD Telephone under test with a known good DYAD Tele- phone and retry test. If proper verifi- cation is not obtained or busy tone is returned again, replace the SLMD PCB. I - 6-20
I - SATURN HE EPABX Installation Test Procedures A30808-X5130-8120-1-8928 Issue 1, May 1986 IS BUTTON DYAD 26 BUTTON DYAD SEE NOTE NOTE: These buttons do not contain LEDs. SEE NOTE y / ’ I Figure 6.20 Siemens DYAD Telephone Button Depression Sequence 6-21
SATURN IIE EPABX Installation Test Procedures A30808-X5130-BlZO-l-8928 Issue 1, May 1986 Table 6.06 Siemcns Digital Telephone - JR-DYAD Button Test NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the Siemens Digital Telephone under test is classmarked with TSTAPP feature, the maintenance test phone is ‘not required to enable or disable the Apparatus Diagnostic routines; therefore, perform only steps‘5 through 9. 2) If the system option flag TSTDIAG has been disabled in the data base or the Siemens Digital Telephone under test is not classmarked with the TSTAPP feature, the maintenance test phone is required to enab!e or disable the Apparatus Diagnostic routines; therefore, perfcrm ihe entire procedure (steps 1 through i0). STEP PROCEDURE VERIFICATION IF VERIFICATION IS NOT OBTAINED 1 Place the maintenance test phone Dial tone is returned. off-hook. 2 Dial the Diagncstic Test Access Code. Recall dial tone is returned. 3 Dial 3 to enable the Apparatus Diag- Confirmation tone is returned. nostic Tests, 4 Place maintenance test phone None. on-hook. 5 Place JR-DYAD Telephone off-hook. Dial tone is rereturned. 6 Dial the Siemens Digital Telephone Recall dial tone is returned. If reorder tone is returned, the Sie- Test Access Code. mens JR-DYAD Telephcne Button Test is in use, try later. 7 Depress the Siemens JR-DYAD Tele- Ii proper verification is net obtainsd or phone keypad buttons as, follows: 1, busy tone is returned at any iime, 2, 3, 4, 5, 6, 7, 8, 9, 0, * , #. either the keypad buttons or feature buttons were depressed out of se- 8 Depress the JR-DYAD feature buttons Button LEDs light when depressed quence, the JR-DYAD Telephone is in the sequence shown in Figure 6.21. and extinguish when the next button defective, or the SLMD circuit is is depressed. defective. To isolate the failure, retry test to verify that the buttons were not After the last button is depressed, the depressed out of sequence. following indications occur: If proper verification is not obtained or Ringbac!c tone is returned. busy tone is returned again, replace All button LEDs flash. the Siemens JR-DYAD Telephone un- der test with a known good JR-DYAD The audible alerting device sounds at Telephone and retry test. If proper intervals. verification is not obtained or busy tone is returned again, the SLMD cir- cuit is defective and the SLMD PC6 requires replacement. 9 Place Siemens JR-DYAD Telephone Siemens JR-DYAD Telephone returns under test on-hook to terminate test. to normal operation. 10 If no additional Apparatus Diagnostic Test routines are to be performed, pro- ceed as follows: P&tokmaintenance test phone Dial tone is returned. Dial the Diagnostic Test Access code. Recall dial tone is reiurned. Dial 2 to disable the Apparatus Diag- None. nostic Test. Place maintenance test phone None. on-hook. 6-22