I - A80808-X5180-8110-1-8928 issue 1, May 1986 Table 4.14 Premium Instrument Module Digital (PIMD) PCB (S30810-Q432-X- * -8900) DESCRIPTION: The PIMD PCB serves as a special line interface circuit connecting attendant consoles to the system. The PIMD communicates with the system via digital data messages. Each PIMD PCB, shown in Figure 4.28, contains two circuits. 1. Indicators. None. 2. Switches. None. 3 Strapping Options. None. OBSERVATIONS: None. INSTALiATdN PROCEDURES: Locate in any channel group in the basic or LTU shelf for optimum port usage. Refer to Section 2.00 of the practice for details. L 442
I - SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 Issue 1. May 1986 . Figure 4.28 PIMD PCB 4-43
SATURN HE EPABX A3O808-X5130-f3110-1-B928 Installation Procedures Issue 1, May 1986 I Table 4.15 Subscriber Line Module Analog - Station (SLMA-S) PCB (S30810-Q1674-X- * -B900) I DESCRIPTION: OBSERVATIONS: INSTALLATION PROCEDURES: The SLMA-S PCB provides an interface between standard telephone sets (rotary dial and pushbutton) and the system. The SLMA-S PCB, shown in Figure 4.29 , contains eight circuits (0 - 7) and utilizes eight ports. Each circuit provides the required supervisory signaling plus the analog-toPCM and PCM- to-analog transformation. 1. Indicators. One green LED which indicates the following status conditions: a. LED lit steadily - One or more of the line circuits are busy. b. LED extinguished - All assigned line circuits are idle and in-service. c. LED flashing - All assigned line circuits are idle and one or more line circuits are in the out-of-service state. 2. Switches. None: 3. Strapping Options. None. The SLMA-S PCB can be used to terminate dial dictation circuits or ZUNA (Zoned Universal Night An- swer) bells zoned for up to four zones, or other special equipment circuits. Locate in any channel group per best port capacity
SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 Issue 1, May 1986 , Gieen LED Figure 4.29 SLMA-S PCB 4-45
I - A30808-X5130-8110-l-8928 Issue 1, May 1986 Table 4.16 Subscriber Line Module Analog - Off-Premises (SLMA-0) PCB (S30810-Ql7’39-X- * -B900) DESCRIPTION: . . *’ The SLMA-C PCB provides an interface between standard telephone sets (rotary dial and pushbutton) which are Off-Premises and the system. The SLMA-CI PCB, shown in Figure 4.30 , contains four circuits (0, 2, 4, 6) and utilizes four ports. Each circuit provides the required supervisory signaling plus the analog toPCM and PCM-to-analog transformation. The Off-Premises station can operate over a loop of 0 to 1800 Ohms, and is registered with the FCC for class “c” operation. 1. Indicators. One green LED which indicates the following status conditions: a. LED lit steadily - One or more of the line circuits are busy. b. LED extinguished - All assigned line circuits are idle and in-service. c. LED flashing - All assigned line circuits are idle and one or more line circuits are in the out-of-service state. OBSERVATIONS: INSTALLATION PROCEDURES: 2. Switches. None. 3 Strapping Options. None. None. Locate in any channel group per best port capacity. Refer to Section 2.00 of this practice for details. 4-46
SATURN HE EPABX installation Procedures A30808-X5130-8110-l-8928 Issue 1, May 1986 I Figure 4.30 SLMA-0 PCB 4-47 I -
I - SATURN HE EPABX installation Procedures A30808-X5130-Bllo-l-8928 Issue 1, May 1986 Table 4.17 Subscriber Line Module Digital (SLMD) PCB (S30810-Q1724-X-*-8900) DESCRIPTION: The SLMD PCB provides an interface between standard Siemens digital telephone (SDT) sets and the system. The SLMD PCB, shown in Figure 4.31 , contains eight circuits (O-7) and utilizes eight ports. 1. Indicators. One red LED which indicates the following status conditions: a. LED lit steadily - One or more of the line circuits are busy b. LED extinguished - All assigned line circuits are idle and in-service. c LED flashing - All assigned line circuits are idle and one or more line circuits are in the out-of-service state. 2. Switches. None. 3. Strapping Options. None. I OBSERVATIONS: None. INSTALLATION Locate in any channel group in the basic or LTU shelf for optimum port usage. Refer to Section 2.00 PROCEDURES: of this practice for details. - 4-48
I - SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 issue 1, May 1986 Figure 4.31 SLMD PCB 4-49
SATURN IIE EPABX Installation Procedures Issue 1, May 1986 Table 4.18 Subscriber Line Analog - 18 Line(SLA16) PCB (S30810-Q1790X * -8900) DESCRIPTION: The SlAl6 PCB, shown in Figure 4.32, provides sixteen interfacing circuits (O-7 for upper half and O-7 in virtual slot for lower half) between rotary dial and/or DTMF stations and the system. 1. Indicators. One green LED which indicates the following status conditions: a. LED lit steadily - One or more of the line circuits are busy. b. LED extinguished - All assigned line circuits are idle and in-service. c. LED flashing - All assigned line circuits are idle and one or more line circuits are in the out-of-service state. 2. Switches. None. OBSERVATIONS: INSTALLATION PROCEDURES: 3 Strapping Options. None. None. Locate in any channel group in the basic or LTU shelf for optimum port usage. Refer to Section 2.00 of this oractice for details. 4-50
- SATURN HE EPABX Installation Procedures A30808-X5130-BllO-l-8928 Issue 1, May 1986 .’ P557&22.920186 Figure 4.32 SLA16 PCB 4-51