SATURN IIE EPABX Installation Procedures A30808-X5130-8110-1-6928 issue 1. May 1986 PWiUW3ZTiE6 Figure 4.43 CIOP PCB 4-72
SATURN IIE EPABX Installation Procedures A30808-X5130-6110-1-8928 Issue 1. May 1986 Table 4.29 Memory 1.0 Megabyte (MEM4) PCB (S30819-Ql775-X-*-8900) DESCRIPTION: The MEM4 PCB, shown in Figure 4.44, provide 1.0 megabyte of dynamic Random Access Memory (RAM) and its supporting logic to store system data. The memory is organized as 512K words X 16 bits/word, and divided into 64K byte pages. Memory write protection is provided in 1K word segments. MEM4 is arranged for battery backup memory protection to safeguard stored data during short term power out- ages. Also, an Error-Correcting Code is provided to correct any single-bit errors and detect double-bit errors existing in a word. 1. Switches. None, 2. Strapping Options. MEM4 PC8 Vl and V2 must be strapped as follows to provide for 1.0 mega- byte of memory: Vl strapped between 1 and 2 V2 strapped between’ 2 and 3 OBSERVATIONS: Check LEDs for normal indications (Refer to Maintenance and Troubleshooting Section) OBSERVATIONS: None. INSTALLATION PROCEDURES: Locate in basic shelf slot number 27. 4-73
I - SATURN IIE EPABX installation Procedures A30808-X5130-BllO-l-B928 Issue 1. May 1986 P5m143120186 Figure 4.44 MEM4 PCB 4-74
SATURN IIE EPABX A30808-X5130-BllO-l-8928 installation Procedures Issue 1, May 1986 Table 4.30 Memory 256 Kilobyte (MEM3) PCB (S30810-Q174O-X-e-8900) DESCRIPTION: . . The MEM3 PCB, shown in Figure 4.45, provide 256 kilobytes of dynamic Random Access Memory (RAM) and its supporting logic to store system data. The memory is organized as 128K words X 16 bits/ word, with memory write protection provided in 1K word segments. MEMB is arranged for battery backup memory protection to safeguard stored data durin short term power outages. Also, an Error-Correcting-Code is provided to correct any single-bit erro 4 and detect double-bit errors existing in a word. 1. Indicator. None. 2. Switches. None. OBSERVATIONS: INSTALLATION PROCEDURES: 3 Strapping Options. None. None. Locate in basic shelf slot number 28. 4-75
SATURN IIE EPABX A30808-X5130-BllO-l-8928 Installation Procedures Issue 1, May 1986 P5uiuW320166 Figure 4.45 MEM3 PCB 4-76
I - SATURN IIE EPAEX A30808-X5130-8110-l-8928 Installation Procedures Issue 1, May 1986 Table 4.31 Line/lhmk Unit Control (LTUC) PCB (S30810-Q428-X- * -8900) DESCRIPTION: The LTUC PCB. shown in Figure 4.46, provides the tim.ing signals necessary to address a line/trunk unit. It multiplexes and demultiplexes both signal and voice highways. It also provides fault monitoring and reporting of failures associated with the 128.ports it handles. 1. Indicators. Three red LEDs, designated PRS, ALMO, and ALMl, provide visual indications of ex- isting malfunctions as follows: a. Protection Restore Signal (PRS), when steadily lit, indicates that one of the following mal- functions is present: 1. No common control on line. 2. +12Vdc under voltage. 3 -5Vdc under voltage. 4. -48Vdc under voltage. Note: The PRS is delayed 40 ms (nominal) after the occurrence of any one of the previous conditions: b. Alarm 0 (A&IO), when steadily lit, indicates that one of the following malfunctions is present: 1. Loss’of CLK-A (2.048MHz clock) of common control 0 2. Loss of SYP (4ms time pulse) of common control 0 3 Loss of SYNR (ring sync) of common control 0 c. Alarm 1 (ALMl). ALMl is not used in the SATURN IIE 2. Switches. None. OBSERVATIONS: INSTALLATION PROCEDURES: 3. Strapping Options. None. None. Locate in LTU shelf slots 6 and 19.
SATURN IIE EPABX Installation Procedures A30808X5130-8110-1-8928 Issue 1, May 1986 Red LEDs Figure 4.46 LTUC PCB 4-78
I - SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 Issue 1, May 1986 4.08 Attendant Console. The attendant console is used handling special system functions such as paging, message primarily to answer external calls (i.e., incoming trunk calls) and waiting and conference calling. A maximum of 12 attendant con- extend such calls to the appropriate internal stations. The con- soles can be interfaced with a particular system. Refer to Table sole may also be used to assist in placing outgoing calls and 4.32 for furthei information on the attendant console. DESCRIPTION: Table 4.32 Attendant Console (L30808X5130&% * -8900) The attendant console, shown in Section 2.00, is a desk-top unit with which the attendant processes calls and accesses special system features using pushbutton keys and an alphanumeric display. It is 46.99 cm (18.5 in.) wide, 13.08 cm (5.15 in.) high, and 26.47 cm (10.42 in.) deep. A telephone handset is furnished with the console. An optional headset may be substituted for the handset. *’ 1. Indicators. None. 2. Switches. None. 3. Strapping Options. None. OBSERVATIONS: INSTALLATION PROCEDURES: None. 1. Connect the modular coiled cord to the handset and console. 2. Connect the modular line cord into rear of console and a standard modular jack receptacle. Check that the connections in the modular jack receptacle coincide with those shown in Figure 4.47. 3 Insert the appropriate key labels into the plastic caps and lock into their corresponding positions in the console. 4. After the system has been tested, perform the appropriate MDF crossconnections to one PIMD circuit per console. Refer to Section 600 in this practice for details. 4-79
SATURN IIE EPABX Installation Procedures A30808-X5130-BllO-l-8928 issue 1, May 1986 Standard Modular Jack Duolex B-Contact 1 1 Modular Jack Termmation in the rear - bottom of Console internal Circuilry Designaflons I , / L TRRTL F XXXXF I MDF Assignments Via House Cabling -2 2 1 1 -1212+ I Modular Lme Cord bms?-%a386 Figure 4.47 Attendant Console Connections 4-80 (80 pages)
- I - SATURN HE EPABX A30808-X5130-BllO-l-6928 Installation Procedures Issue 1, May 1988 SECTION 5.00 SYSTEM SIGNAL AND POWER/GROUND CABLING ARRANGEMENTS 5.01 General. This section provides the signal and pow- er/ground-cabling arrangements for the SATURN IIE System. Tables 5.00 and 5.01 list all the cable reference numbers used throughout this practice. The tables provide point-to-point ca- ble terminations and refer users to the appropriate cabling illustration for quick reference. The following illustrations are included in this section: NOTE: When an LTU shelf is not equipped its correspond- ing signal cable connector on the basic shelf must : have a Berg jumper inserted across pins 29 and 30 in order to suppress LTU shelf failure alarm. The connectors are designated as follows: ’ c. Basic shelf connectors J57 and J59 , jumpered if LTU3 shelf is missing. Figure 5.00 Backplane Connectors Figure 5.01 Power/Ground Distribution for the SATURN IIE System (Basic Cabinet) Figure 5.02 Power/Ground Distribution for the SATURN HE System (Expansion Cabinet) Figure 5.03 Signal Cable Distribution for the SATURN IIE System (Basic Cabinet) a. Basic shelf connectors J55 and J56, jumpered if LTUl Figure 5.04 Signal Cable Distribution for the SATURN IIE shelf is missing. System (Expansion Cabinet) b. Basic shelf connectors J58 and J60 , jumpered if LTUP shelf is missing. 5-1