Page 81
83 Alarm Group REC Mode:Select the desired setting by clicking on the radio button. EXT:Select this to gen-lock the unit during the alarm recording. INT:Select this if the asynchronous unit is connected to the unit. When it is activated, the drop-down menu becomes also active so that you can select the desired normal recording rate. 002, 004 to 128 (field) are selectable. The factory default setting is EXT. DYNAMIC REC:Select the desired setting by clicking on the drop-down menu. ALM-PRI:Select this to...
Page 82
84 ●Multiplexer Title ●How to Display To display this window, click on the (Multiplexer Title) button in the main window (p. 65.) ●How to Display Note:This window can be displayed only when Yes is selected in the Recorder window. (Refer to p. 66.) ●Parameters The factory default settings are same as the illustration. (The text box covered with the cursor is “C”.) To edit the desired camera’s title, click on the associated button (Cam 1 to Cam 16). The subsequent editing procedure is the same as Camera...
Page 83
85 ■Account Manager This window configures the parameters of the operators who can control WJ-SX150 Administrator Console: the reg- istration, edit and deletion of an operator. The window soon after opening The window during the edit ●How to Display To display this window, click on the (Account Manager) button in the main window (p. 65). Note: Register at least one operator with level 1. If there is no level 1 operator, the configuration of WJ-SX150 Administrator Console will become impossible....
Page 84
86 ■Communication Port This window configures the PCs usable communication port number and its baud rate (communication speed). ●How to Display To display this window, click on the (Communication port) button in the main window (p. 65). ●Parameters • Parameter Group Com:Select the PCs communication port for the con- nection to the unit. Baud Rate:Select the desired baud rate (communica- tion speed). 4800, 9600, 19200 or 38400 bps is selectable. The factory default setting is 38400 bps. • Fixed Parameter...
Page 86
88 LOG-IN AND LOG-OUT Before starting the following procedures, all system compo- nents must be turned on. The following procedures are applicable when the system controller is connected to the unit. ■ Log-in This operation is skipped when the auto log-in is set to ON. (Refer to p. 89.) 1. Turn on the power switches of all system components. The OPERATE indicator will light up. 2. To turn on the power of the system controller, connect the AC adapter to the AC outlet. The LINK indicator lights up and NO...
Page 87
89 ■ Log-out This operation is skipped when the auto log-out is set to ON. This function is used when an operator leaves the controller or no longer requires access to the system. 1. To logout from the system press the CLEAR button while holding down the SHIFT button. NO USER appears on the LED display of the con- troller. Notes: •If you want to save the power consumption, discon- nect the PC plug from the controller, and remove the AC adapter from the AC outlet. •If the auto log-out is set to ON, any...
Page 88
90 ■ Priority Lock ● Applying Priority Lock 1. Select the desired monitor. (Refer to Monitor Selection). 2. Press the MON (ESC) button while holding down the SHIFT button to toggle the priority lock mode on and off on the active monitor. If the priority lock mode is selected, the monitor number will inversely appear on the active monitor as shown in the figure. Note:This function will prevent operators with lower priority from gaining control of a monitor. However, higher or equal priority operators may...
Page 89
91 ■ Camera Selection 1. Select the desired monitor. (Refer to p. 90 Monitor Selection.) 2. Press the numeric buttons to select the desired camera number (1 to 16). 3. Press the CAM (SET) button. The selected cameras image will appear on the active monitor. The CAMERA indicator will light up and the selected camera number will appear on the LED dis- play on the controller. SETUP SHIFT REW/FF STEP GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD RECORDER INDEX STOP...
Page 90
92 Buttons and control for cameras or camera site accessories are located on the right side of the front panel of the system controller. Included are zoom control, focus control, iris control, preset and pan/tilt controls. Normally, combination cameras equipped with the specific feature or a WV-RC100 or WV-RC150 Receiver are required to utilize these functions. Note:Refer to the cameras operating instructions whether to confirm that each function is available. ■ Lens Control This function is available...