Page 91
93 ■ Call Preset Position 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. To select the desired preset position number, press the numeric buttons. 4. When you have selected a wrong number, press the CLEAR button to clear the numeric input. 3. Press the CALL PRESET button to move to the preset position of the selected camera on the active monitor. ■ Program Preset Position 1. Select the desired monitor and camera. (Refer to p. 90 Monitor...
Page 92
94 ■ Camera Function (Shortcut Function) The following function is available only when specified cam- eras with the camera function feature are used. This function enables executing camera functions via a shortcut. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button while holding down the SHIFT button. F_ _ _ _ will appear on the LED display of the con- troller as shown in the figure. ■ Camera Setup 1. Select the desired...
Page 93
95 ■ Patrol Learn and Play A routine of manual operations can be stored for a specific time and later reproduced repetitively. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button three times while holding down the SHIFT button. LEARN will appear on the LED display of the controller as shown in the figure. ■ Changing to Black and White Images This function gets the clear camera images on the monitor while shooting the...
Page 94
96 ■ Camera Panning Function There are three panning modes available as follows: auto pan, sort mode and sequence mode. Refer to p. 16 Camera-related Functions for details on each mode. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button four times while holding down the SHIFT button. PAN will appear on the LED display of the controller as shown in the figure.4. To exit from the mode, press the MON (ESC) button, then press...
Page 95
97 ■ Receiver Control The following functions are available only when the receivers are included in the system and the specified camera housing is installed. ● Camera Housing Control Wiper Control 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the CAM (SET) button while holding down the SHIFT button to turn on the housing wiper of the camera until buttons are released. Defroster Control 1. Select the desired monitor and camera. (Refer to...
Page 96
98 ■ Tour Sequence The following functions are available if a tour sequence has been previously configured through SETUP MENU or WJ- SX150 Administrator Console. Any tour sequence can be assigned to any monitors. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. To select the desired tour sequence number, press the numeric buttons. 3. When you have selected a wrong number, press the CLEAR button to clear the numeric input. 4. Press the TOUR SEQ...
Page 97
99 ■ On-screen Display (OSD) Control The procedure described below lets you determine the dis- play parameters, such as camera title, clock and status, on and off on the active monitor screen. Before controlling each item, monitor selection is neces- sary. (Refer to p. 90 Monitor Selection.) ●Displaying the Clock Toggle the button 1 while holding down the OSD button. (1) will appear/disappear on/from the active monitor. ●Displaying the Camera Title Toggle the button 2 while holding down the OSD...
Page 98
100 MODE:Lists the display mode on the moni- tors. SPOT:Spot mode Tnn:Tour Sequence mode (nn is the tour sequence number.) SET:WJ-SX150 Setup mode ALARM:Alarm Active mode ACK:Alarm ACK mode VLD H:VLD History Table ALM H:Alarm History Table SYS S:System Status Table KB:Lists the system controller number or PC. OPE:Lists the operator number PRI:Lists the priority number 3. To exit from the mode, press the CLEAR button.●Moving the Event Display Move the joystick while holding down the OSD, SHIFT and 3...
Page 99
101 ■ Alarm History Table There are 100 alarm records stored in chronological order in 10 pages of tables. 1. Select the desired monitor. (Refer to p. 90 Monitor Selection.) 2. Press the button 7 while holding down the OSD button. OSD will appear on the LED display, and the ALARM HISTORY table will appear on the active monitor as shown in the figure. The columns in the table indicate the states as follows: DATE:Lists the date and time when the alarm state changes. ALARM:Lists the alarm number (01 - 16)....
Page 100
102 ■Operating during an Alarm Mode While an alarm mode is active, the following are available from the system controller: •Operating the camera with the alarm input (ACK) •Resetting the alarm (RESET/ALL RESET) •Suspending the alarm (ALM SUSPENDED) ■Operation of an Alarm-related Camera (ACK) You can operate the camera with the alarm input as follows: 1. Select a monitor which displays ALARM. 2. Press the ACK button. ACK will appear on the monitor with an alarm input. The camera with an alarm input will...