Panasonic Matrix Switcher Wj Sx150 Operating Instructions
Here you can view all the pages of manual Panasonic Matrix Switcher Wj Sx150 Operating Instructions. The Panasonic manuals for Recording Equipment are available online for free. You can easily download all the documents as PDF.
Page 131
135 PAN/TILT ItemTransmission Command (ASCII)Response (ASCII) Parameter (ASCII)CMD:CmmPTccxxyy — mm=Monitor No. cc=Camera No. • Panning speed xx=00 STOP xx=01 to 40(HEX) + direction panning (Max is 40 and min is 01) xx=81 to C0(HEX) - direction panning (Max is C0 and min is 81) • Tilting speed yy=00 STOP yy=01 to 40(HEX) + direction tilting (Max is 40 and min is 01) yy=81 to C0(HEX) - direction tilting (Max is C0 and min is 81) Camera Control CMD:CmmZMccn Zoom — mm=Monitor No. cc=Camera No. n=0...
Page 132
136 136 AUX2 CMD:CmmA2ccn —mm=Monitor No. cc=Camera No. n=0 OFF n=1 ON AUX1 CMD:CmmA1ccn —mm=Monitor No. cc=Camera No. n=0 OFF n=1 ON mm=Monitor No. cc=Camera No. n=0 OFF (Color) n=1 ON (BW) mm=Monitor No. cc=Camera No. n=0 STOP n=1 PLAY n=2 LEARN mm=Monitor No. cc=Camera No. nnn=Camera function No. (001 to 256) ItemTransmission Command (ASCII)Response (ASCII) Parameter (ASCII) Cameras SETUP MENU CMD:CmmCMccn — mm=Monitor No. cc=Camera No. n=0 OFF n=1 ON The following commands are available in SETUP...
Page 133
137137 Transmission command toggles zoom. mm=Monitor No. n=0 Zoom OFF n=1 + mark display ON n=2 Two-fold zoom n=4 x4Live image/Playback image n=8 x8Live image/Playback image CMD:RmmZM Multiscreen segment switch- ing Recorder Control ItemTransmission Command (ASCII)Response (ASCII) Parameter (ASCII) CMD:RmmML ANS:RmmML mm=Monitor No. Electronic Zoom ANS:RmmZMn Play CMD:RmmPL ANS:RmmPL mm=Monitor No. Pause CMD:RmmPA ANS:RmmPA mm=Monitor No. Stop CMD:RmmSPn ANS:RmmSPn mm=Monitor No. n=0 Stop playback...
Page 134
138 Available only with the Multiplexer Transmission command toggles still display ON or OFF. mm=Monitor No. cc=Camera No. (cc=00 when toggling multiscreen still ON or OFF) n=0 OFF n=1 ON mm=Monitor No. FF ItemTransmission Command (ASCII)Response (ASCII) Parameter (ASCII) CMD:RmmFF ANS:RmmFF REW CMD:RmmRW ANS:RmmRW mm=Monitor No. Forward field advance CMD:RmmFA ANS:RmmFA mm=Monitor No. Backward field advance CMD:RmmRA ANS:RmmRA mm=Monitor No. Record CMD:RmmRC ANS:RmmRC mm=Monitor No. Index CMD:RmmSC...
Page 135
139 Alarm history ItemTransmission Command (ASCII)Response (ASCII) Parameter (ASCII) Model No QID qid:WJ-SX150 Matrix switchers model No. Software version QRV qrv:*.** qrv:*.**/*.***.**=Matrix switchers software version *.**/*.**: Matrix switcher’s software ver- sion/Multiplexer board’s version Inquiry Video loss historyQAD QVDqad:nnn:YYYYMMDD hhmmss:cc:ee:s qvd:nnn: YYYYMMDD hhmmss:cc:ee:snnn=alarm-event total number (000 to 100) *=Event of alarm n (n is a number). Display pattern:...
Page 136
140 Alarm display–ALM:cc:a:yyyymmdd:hhmm ss:ba=Event 0=ALARM 1=ACK 2=RESET yyyy=Year mm=Month dd=Day hh=Hour ss=Second b=Daylight saving time (summer time) 0=OFF 1=ON ItemTransmission Command (ASCII)Response (ASCII) Parameter (ASCII) Miscellaneous Control
Page 137
141 ■Error Code List Error code(ASCII) Error type Meaning ER000 No error There is no error. ER001 No associated command There is no associated command. ER002 Parameter invalid The parameters number, digit and range are invalid. ER003 Receiver buffers overflow The receiver buffer has reached overflow capacity. Error code(ASCII) Error type Meaning ER301 Command invalid Invalid operation mode caused the command error. ER302 Parameter invalid The parameters number, digit and range are valid, but the...
Page 138
142 WORKSHEETS Gathering information for the initial configuration and recording on the following worksheets are recommended. Then, if set- tings need to be modified or updated later because of a change in surveillance needs or changes made in the systems com- ponents, those worksheets can be used to track revisions to your system. You should keep all revised worksheets. Be sure to date them, in preparation for new entry or troubleshooting. Regardless of the system size, the worksheets can track past,...
Page 139
143 ■Checklist It is recommended that the worksheets be completed in the following sequence: Date completed: ___/ ___/ ___ ●Recorder ●Tour Sequence Step 1 2 3 4Camera Preset position Dwell time RemarkTour __ / 16 5 6 7 8 9 10 11 12 13 14 15 16 Step 1 2 3 4Camera Preset position Dwell time RemarkTour __ / 16 5 6 7 8 9 10 11 12 13 14 15 16 Built in multiplexer board Recorder Control Unit Address EXT IN Yes/No OFF/HD100/HD200/HD500/VCR Genlock off/on
Page 140
144 ●Group Sequence Step 1 2 3 4Camera Preset position Dwell time RemarkTour __ / 16 5 6 7 8 9 10 11 12 13 14 15 16 Group 1 2 3 4Monitor 1 Monitor 2 Monitor 3 Monitor 4