Panasonic Matrix Switcher Wj Sx150 Operating Instructions
Here you can view all the pages of manual Panasonic Matrix Switcher Wj Sx150 Operating Instructions. The Panasonic manuals for Recording Equipment are available online for free. You can easily download all the documents as PDF.
Page 101
103 1. Press the RESET button while holding down the SHIFT button. 2. The monitor, the LED display and the indicator will change as follows: ALARMnn will disappear from the monitor. The LED display will return to the state before the alarm input. The alarm indicator will go out. The CAM indicator will return to the state before the alarm input. ■Suspending the Alarm Inputs Use this function when you do not want to be disturbed by an alarm input, for example, during the setup procedures. 1. Press the...
Page 102
104 MULTIPLEXER OPERATIONS Multiplexer board WJ-SXB151 is an optional board. It enables multiscreen display, electronic zooming, still pic- ture and multiscreen sequence. It also enables the operation of Digital Disk Recorder WJ- HD100 Series or time-lapse VCR, when connected to them. Note:Before the use, it is necessary to install the Multiplexer board in the matrix switcher and config- ure the system through SETUP MENU and WJ- SX150 Administrator Console. [Refer to p. 34 Installing the Multiplexer...
Page 103
105 ●Electronic Zooming (EL-ZOOM) Playback spot pictures can be electrically zoomed. 1. Select the desired monitor. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the RECORDER button. (Refer to p. 116 Recorder Mode.) The system will enter the recorder mode. 3. Press the PLAY button. (Refer to p. 117 Normal Playback.) The system will enter the playback mode. 4. Select a camera channel by pressing a numeric button and then pressing the CAM (SET) button. The selected camera image...
Page 105
108 WHEN USING A PS·DATA SYSTEM CONTROLLER This manual describes the operating procedures which are specifically related to WJ-SX150. For the basic operating procedures such as log-in/log-out, camera selection, and camera control, etc., refer to the system con- trollers operating instructions. The following are different from the terminal mode when you use the system controller via the PS·Data protocol. •Camera selection, camera control, camera site accessories control are in accordance with the PS·Data...
Page 106
109 Refer to the system controller’s operating instructions before you login the system. After the log-in procedure, the following operations are available to control the system. The operation begins with selecting a monitor, then the selected camera appears the active monitor. ■ Monitor Selection Unit addresses are given to each monitor. Rotary SW Mon 1 Mon 2 Mon 3 Mon 411234 The following is how to select a monitor. 1. Press the numeric button(s) to select the desired moni- tors unit address. 2. Press...
Page 107
110 ■ Tour Sequence The following functions are available if a tour sequence has been previously configured through SETUP MENU or WJ- SX150 Administrator Console. Any tour sequence can be assigned to any monitors. 1. Select the desired monitor. (Refer to p. 109 Monitor Selection.) 2. To select the desired tour sequence number, press the numeric buttons. 3. Press the SEQ button to run the tour sequence in the forward direction on the active monitor. 4. Press the SEQ PAUSE button to pause a tour sequence...
Page 108
111 The procedure described below lets you determine on-screen display (OSD) items, such as camera title, clock and status, on and off on the active monitor screen. Before controlling each item, monitor selection is necessary. (Refer to p. 109 Monitor Selection.) 1. Press the SHIFT button, and then press the numeric buttons corresponding to the function code. (Refer to the table.) 2. Press the FUNCTION button. The function will be executed. Notes: •Alarm History Table doesnt have a function code. When...
Page 109
112 ■Resetting All the Alarm Inputs You can reset all the alarm input signals at a time. 1. Select a monitor which displays ALARM. (Refer to the figure on p. 102.) 2. Press the SHIFT button, and then press the ALL RESET button. All the alarms will be reset. Then, the LED display and indicators will return to the state before the alarm input. Note:You cannot reset the alarm input signals one by one. ■Suspending All the Alarm Inputs Use this function when you do not want to be disturbed by an alarm input,...
Page 110
113 This section will describe what you should take notice when using a PS·Data system controller. The same descriptions as the system controller’s operating instructions are not mentioned here. Refer to them. ■Controlling the Unit with a PS·Data System Controller 1. Before operating the recorder, it is necessary to enter the recorder mode. (Refer to p. 124 or p. 125.) 2. Enter the desired function code (refer to the diagram) and press the FUNCTION button. MULTIPLEXER OPERATIONS (PS · Data)