    1. Press the RESET button while holding down the SHIFT
    button.
    2. The monitor, the LED display and the indicator will
    change as follows:
    ALARMnn will disappear from the monitor.
    The LED display will return to the state before the
    alarm input.
    The alarm indicator will go out.
    The CAM indicator will return to the state before the
    alarm input.
    ■Suspending the Alarm Inputs
    Use this function when you do not want to be disturbed by
    an alarm input, for example, during the setup procedures.
    1. Press the ACK/SUSPEND button while holding down
    the SHIFT button.
    ALM SUSPENDED will appear on the monitor.
    2. To cancel alarm suspension, press the ACK/SUSPEND
    button while holding down the SHIFT button again.
    ALM SUSPENDED will disappear from the monitor.
    Notes:
    •An alarm continues to operate even after it is suspend-
    ed.
    •
    If you suspend an alarm while an alarm image is dis-
    played, ALM SUSPENDED will not appear on the moni-
    tor. Reset the alarm, and then suspend it 
    again. 
    ■Resetting the Alarm Inputs
    There are two alarm reset functions:
    •Alarm reset (resetting the alarm inputs according to the
    input order)
    •Alarm all reset (resetting all the alarm inputs)
    ● Alarm Reset
    1. Select a monitor which displays ALARM.
    2. When more than one alarm signal has been input, the
    second earliest alarm image appears on the monitor,
    after the current alarm image is reset.
    3. To reset all the alarms, repeat steps 1 and 2. The moni-
    tor, the LED display and the indicator will change as fol-
    lows:
    ALARMnn will disappear from the monitor.
    The LED display will return to the state before the
    alarm input.
    The alarm indicator will go out.
    The CAM indicator will return to the state before the
    alarm input.
    Note:When more than one alarm is input and they are
    associated with the same monitor, they will be reset one
    by one. 
    ● Alarm All Reset
    T&D CAM IDEVENT
    AUX1 ON AUX1 OFFSTILL
    ALL RESET
    RESET
    TOUR SEQ
    Alarm
    input 1Alarm
    input 5Alarm
    input 2
     • Description about alarm reset
    Monitor 1 Matrix switcher
    ALARM01*
    ALARM05*
    ALARM02
    ALL RESET
    RESET
    ALL RESET
    RESET
    Monitor 1
    Time
    SHIFT
    PAUSE NEXT
    PAUSE
    MON LOCK
    DEF ON
    WIPER
    DEF OFFMON (ESC)
    T&D CAM ID
    MON STATUSALLEVENT
    ALM H VLD H SYS S
    CAM (SET)
    MULTI SCREEN SEL
    SEQUENCE
    AUX2 ON AUX2 OFFEL-ZOOM
    AUX1 ON AUX1 OFFSTILL
    ALL RESET
    RESET
    TOUR SEQ
    MON LOCK
    DEF OMON (ESC)
    T&D CAM 
    MON STATUSALL
    ALM H VLD 
    MULTI SCRE
    SEQUENCE
    AUX2 OEL-ZOOM
    AUX1 OSTILL
    SHIFT
    REW/FF
    STEP
    GROUP SEQ
    PAUSE
    SUSPEND ALL RESET
    ACKRESET
    TOUR SEQ
    PREVNEXT
    OSD
    PLAYPAUSE
    ALM SUSPENDED 
    						
    							104
    MULTIPLEXER OPERATIONS 
    Multiplexer board WJ-SXB151 is an optional board.
    It enables multiscreen display, electronic zooming, still pic-
    ture and multiscreen sequence.
    It also enables the operation of Digital Disk Recorder WJ-
    HD100 Series or time-lapse VCR, when connected to them.
    Note:Before the use, it is necessary to install the
    Multiplexer board in the matrix switcher and config-
    ure the system through SETUP MENU and WJ-
    SX150 Administrator Console. [Refer to p. 34
    Installing the Multiplexer Board, p.52 WJ-SX150
    SETUP MENU (OSD), and p. 64 WJ-SX150 ADMIN-
    ISTRATOR CONSOLE.]
    ■Monitoring the Camera Picture
    ●Multiscreen Segment Switching
    Refer to p. 117 Multiscreen Segment Switching for details.
    ●Multiscreen Sequence
    Camera images are switched automatically in a sequence
    mode.
    The sequence mode (QUAD, 3+1, 8+1) is configurable
    through WJ-SX150 Administrator Console.
    (Refer to p. 82 Sequence Mode of Multiplexer Mode for
    details.)
    1. Select the desired monitor and camera. (Refer to p. 90
    Monitor Selection and p. 91 Camera Selection.)
    The monitor number and camera number will appear on
    the LED display.
    2. Press the RECORDER button. (Refer to p. 116 Recorder
    Mode.) The system will enter the recorder mode.
    3. Press the button 7 while holding down the SHIFT but-
    ton.
    A sequence of multiscreen pictures is displayed
    according to the WJ-SX150 Administrator Consoles
    configuration.
    4. To cancel the sequence, press the button 0 while hold-
    ing down the SHIFT button.
    Note:The sequence mode can also be cancelled by press-
    ing a numeric button (corresponding one to the monitor
    number), then the CAM (SET) button.
    ●Still Playback Spot Picture
    The spot picture is changed into the still picture.
    1. Select the desired monitor and camera number. (Refer
    to p. 90 Monitor Selection and Camera Selection.)
    The monitor number and camera number will appear on
    the LED display.
    2. Press the RECORDER button. (Refer to p. 116 Recorder
    Mode.) The system will enter the recording mode.
    3. Press the PLAY button. (Refer to p. 117 Normal
    Playback.) The system will enter the playback mode.
    4. Select a camera channel by pressing a numeric button
    and then pressing the CAM (SET) button. The selected
    camera image will be displayed in a spot picture.
    5. Press the button 1 while holding the SHIFT button. The
    selected camera image will change into the still picture.
    6. To cancel the still picture, press the button 1 while hold-
    ing down the SHIFT button again.
    Note:Still picture is not available while zooming is acti-
    vated.
    ●Still Multiscreen Picture
    Still pictures can also be displayed in a multiscreen.
    1. Select the desired monitor and camera number. (Refer
    to p. 90 Monitor Selection and Camera Selection.)
    The monitor number and camera number will appear on
    the LED display.
    2. Press the RECORDER button. (Refer to p. 116 Recorder
    Mode.) The system will enter the recorder mode.
    3. Press the numeric button corresponding to the camera
    number.
    4. Press the button 1 while holding down the SHIFT but-
    ton.
    The selected camera image will change into the still
    picture.
    STILL and the camera title alternately blinks on the
    monitor.
    5. To cancel the still picture, press the button 1 while hold-
    ing down the SHIFT button again.
    Notes:
    •“STILL” does not appear when the still display is set to
    OFF.
    •When you skip Step 3 and do Step 4, all the channels
    displayed in the multiscreen segments will be changed
    into the still pictures. 
    						
    							105
    ●Electronic Zooming (EL-ZOOM)
    Playback spot pictures can be electrically zoomed.
    1. Select the desired monitor. (Refer to p. 90 Monitor
    Selection and p. 91 Camera Selection.)
    2. Press the RECORDER button. (Refer to p. 116 Recorder
    Mode.) The system will enter the recorder mode.
    3. Press the PLAY button. (Refer to p. 117 Normal
    Playback.) The system will enter the playback mode.
    4. Select a camera channel by pressing a numeric button
    and then pressing the CAM (SET) button. The selected
    camera image will be displayed in a playback spot pic-
    ture.
    5. Press the button 4 while holding down the SHIFT but-
    ton.
    “+” sings will appear on the image.
    6. To move the “+” signs within the picture, move the joy-
    stick.
    7. Press the button 4 while holding down the SHIFT but-
    ton. The area surrounded by the “+” signs will be
    zoomed up.
    8. To move the zoom area, move the joystick.
    9. To cancel the zooming, press the button 4 while holding
    down the SHIFT button again.
    Note:Still picture is not available while zooming is acti-
    vated. 
    						
    							107
    OPERATING PROCEDURES
    (PS·DATA) 
    						
    							108
    WHEN USING A PS·DATA SYSTEM CONTROLLER
    This manual describes the operating procedures which are specifically related to WJ-SX150.
    For the basic operating procedures such as log-in/log-out, camera selection, and camera control, etc., refer to the system con-
    trollers operating instructions.
    The following are different from the terminal mode when you use the system controller via the PS·Data protocol.
    •Camera selection, camera control, camera site accessories control are in accordance with the PS·Data System operating
    procedures. Refer to the system controllers operating instructions.
    •You cannot reset an alarm one by one per monitor. However, you can reset all the alarms at a time (ALL RESET).
    •You cannot acknowledge an alarm.
    •You cannot use the auto log-in function of the unit.  To use this function, use a terminal-mode system controller.
    •You cannot use the auto log-out function of the unit.
    •You cannot move the clock, camera title, event, and/or monitor status display with a PS·Data controller. Use a terminal-
    mode system controller.
    •Operators using the PS·Data system controller have the highest priority to all those using the terminal-mode system con-
    trollers.
    •PS·Data doesn’t support user-management, and you cannot configure the PS·Data operator registration neither through
    SETUP MENU nor WJ-SX150 Administrator Console.
    Notes:
    •When you select a monitor with a PS·Data system controller, you might enter its number as you do in the terminal mode.
    However, the matrix switcher regards a monitor as a unit, you need to select it by the unit number. (Refer to p. 109.)
    •This unit is counted as 4 PS·Data units. Confirm the total number of the PS·Data units in your system. 
    (Up to 16 PS·Data units are available.) 
    						
    							109
    Refer to the system controller’s operating instructions
    before you login the system. After the log-in procedure, the
    following operations are available to control the system.
    The operation begins with selecting a monitor, then the
    selected camera appears the active monitor.
    ■ Monitor Selection
    Unit addresses are given to each monitor. 
    Rotary SW Mon 1 Mon 2 Mon 3 Mon 411234
    The following is how to select a monitor.
    1. Press the numeric button(s) to select the desired moni-
    tors unit address.
    2. Press the UNIT button.
    The selected monitor will be activated.
    ■ Priority Lock
    You can apply or release priority lock by entering the func-
    tion code. Monitor display is the same as those of terminal
    mode. (Refer to p. xx for the illustrations.)
    1. Select the desired monitor. (Refer to Monitor Selection).
    2. Press the SHIFT button, and enter 101 by pressing the
    numeric buttons. 
    3. Press the FUNCTION button. The function will be exe-
    cuted.
    If the priority lock mode is selected, the monitor number
    will inversely appear on the active monitor.
    4. To release the priority lock, do steps 2 and 3 again.
    Note:This function will prevent operators in the terminal
    mode from gaining control of a monitor. However, oper-
    ators via the PS·Data protocol can still gain control.
    MONITOR CONTROL 
    						
    							110
    ■ Tour Sequence
    The following functions are available if a tour sequence has
    been previously configured through SETUP MENU or WJ-
    SX150 Administrator Console. Any tour sequence can be
    assigned to any monitors.
    1. Select the desired monitor. (Refer to p. 109 Monitor
    Selection.)
    2. To select the desired tour sequence number, press the
    numeric buttons.
    3. Press the SEQ button to run the tour sequence in the
    forward direction on the active monitor.
    4. Press the SEQ PAUSE button to pause a tour sequence
    on the active monitor.
    A series of camera picture appear in pause on the mon-
    itor screen for the specified dwell time.
    5. Press the SEQ PAUSE button again to restart a tour
    sequence forward from the next step that was previous-
    ly paused by pressing the SEQ PAUSE button.
    6. Press the SHIFT button, and then press the + button to
    move the sequence one frame to the next step from the
    step that was previously paused by pressing the
    PAUSE button.
    Press the SHIFT button, and then press the - button to
    move the sequence one frame to the previous step from
    the step that was previously paused by pressing the
    PAUSE button.
    7. Select a camera (refer to the system controllers operat-
    ing instructions) to stop the sequence. The monitor will
    return to the spot mode.
    ■ Group Sequence
    The following function is available only if a group sequence
    has been previously established in WJ-SX150 Administrator
    Console. The group sequence has ID numbers. Group 1 is
    17, Group 2 is 18, Group 3 is 19, and Group 4 is 20.
    As described earlier, a group sequence determines the
    assignment of monitors and cameras. Therefore, monitor
    selection is not required.
    1. Press the numeric buttons to select a desired group
    sequence ID number, then press the SEQ button.
    2. Press the SEQ button to run a group sequence forward
    on the assigned monitors.
    5. Press the SEQ PAUSE button again to restart a tour
    sequence forward from the next step that was previous-
    ly paused by pressing the SEQ PAUSE button.
    6. Press the SHIFT button, and then press the + button to
    move the sequence one frame to the next step from the
    step that was previously paused by pressing the
    PAUSE button.
    Press the SHIFT button, and then press the - button to
    move the sequence one frame to the previous step from
    the step that was previously paused by pressing the
    PAUSE button.
    7. Select a camera (refer to the system controllers operat-
    ing instructions) to stop the sequence. The monitor will
    return to the spot mode.
    RUNNING SEQUENCE 
    						
    							111
    The procedure described below lets you determine on-screen display (OSD) items, such as camera title, clock and status, on
    and off on the active monitor screen.
    Before controlling each item, monitor selection is necessary. (Refer to p. 109 Monitor Selection.)
    1. Press the SHIFT button, and then press the numeric buttons corresponding to the function code. 
    (Refer to the table.)
    2. Press the FUNCTION button. The function will be executed.
    Notes:
    •Alarm History Table doesnt have a function code. When displaying the table, press the ALM RECALL button instead of
    the steps 1 and 2 above. OSD will appear on the LED display, and the ALARM HISTORY table will appear on the
    active monitor.
    •You cannot control OSD display position.
    MONITOR DISPLAY CONTROL
    Function CodeController Status Note
    Displaying the clock 104 Pressing again will hide the display.
    Displaying the camera title 105 Pressing again will hide the display.
    Displaying the event 106 Pressing again will hide the display.
    Displaying the monitor status107 Pressing again will hide the display.
    Displaying all the items 19 Pressing again will hide the display.
    Displaying System Status 102 OSD appears on the LED. Pressing again will return to the normal display.
    Displaying Video Loss History 103 OSD appears on the LED. Pressing again will return to the normal display. 
    						
    							112
    ■Resetting All the Alarm Inputs
    You can reset all the alarm input signals at a time. 
    1. Select a monitor which displays ALARM.
    (Refer to the figure on p. 102.)
    2. Press the SHIFT button, and then press the ALL RESET
    button.
    All the alarms will be reset.
    Then, the LED display and indicators will return to the
    state before the alarm input.
    Note:You cannot reset the alarm input signals one by one.
    ■Suspending All the Alarm Inputs
    Use this function when you do not want to be disturbed by
    an alarm input, for example, during the setup procedures.
    1. To suspend all the alarm input signals, press the SHIFT
    button., and then press the SUSPEND button.
    The indicator beside the button will light up and ALM
    SUSPENDED will appear on the monitor.
    (Refer to the figure on p. 103.)
    2. To cancel alarm suspension, do Step 1 again.
    Notes:
    •The alarm suspension is applied to all system units,
    not to a selected one.
    •An alarm which was input before the suspension
    will continue to operate.
    ■Alarm Mode
    When alarm (sensor) is accepted, the matrix switchers
    operation mode changes into the alarm mode. Then, the
    system operates as follows:
    •The camera image (alarm image) appears on the moni-
    tor.
    In the factory default setting, the alarm inputs 1 to 16
    are associated with the same-numbered camera input
    connectors. All the video output signals are sent to
    Monitor 1. For example, when the alarm (sensor) con-
    nected to the alarm input 1 becomes active, the camera
    input connector 1’s image appears on Monitor 1.
    •ALARMnn appears on the monitor.
    The display indicates the image is input through the
    alarm nn (nn is the alarm number).
    When more than one alarm signal input has been
    accepted, ALARMnn* appears on the monitor.
    •The alarm indicator will blink.
    •Alarm output signals are supplied from Alarm Output 1
    to 4 (#10, 11, 23 and 24) of the ALARM port (25-pin D-
    sub connector) at the rear panel. Alarm Output 1 to 4 is
    associated with MONITOR OUT 1 to 4. For example,
    when an alarm input signal is activated on MONITOR
    OUT 1, the unit supplies Alarm Output 1 to Monitor 1.
    •The monitor and alarm number will appear on the LED
    display. At the same time, the alarm indicator will blink,
    the monitor indicator will light up, and the camera indi-
    cator will go out.
    Notes:
    •The association of the alarm inputs with cameras and
    monitors are changeable in SETUP MENU or WJ-SX150
    Administrator Console. (Refer to p. 56 or p. 74.)
    •Alarm input will be automatically reset in 30 seconds.
    The auto-recovery time is configurable through SETUP
    MENU or WJ-SX150 Administrator Console.
    ■Operation during an Alarm Mode
    While an alarm mode is active, you can do the following:
    •Resetting all the alarm inputs (ALL RESET)
    •Suspending all the alarm inputs (ALM SUSPENDED)
    ALARM CONTROL 
    						
    							113
    This section will describe what you should take notice when
    using a PS·Data system controller. The same descriptions
    as the system controller’s operating instructions are not
    mentioned here. Refer to them. 
    ■Controlling the Unit with a PS·Data
    System Controller
    1. Before operating the recorder, it is necessary to enter
    the recorder mode. (Refer to p. 124 or p. 125.)
    2. Enter the desired function code (refer to the diagram)
    and press the FUNCTION button.
    MULTIPLEXER OPERATIONS (PS · Data) 
    						
    All Panasonic manuals Comments (0)