103 1. Press the RESET button while holding down the SHIFT button. 2. The monitor, the LED display and the indicator will change as follows: ALARMnn will disappear from the monitor. The LED display will return to the state before the alarm input. The alarm indicator will go out. The CAM indicator will return to the state before the alarm input. ■Suspending the Alarm Inputs Use this function when you do not want to be disturbed by an alarm input, for example, during the setup procedures. 1. Press the ACK/SUSPEND button while holding down the SHIFT button. ALM SUSPENDED will appear on the monitor. 2. To cancel alarm suspension, press the ACK/SUSPEND button while holding down the SHIFT button again. ALM SUSPENDED will disappear from the monitor. Notes: •An alarm continues to operate even after it is suspend- ed. • If you suspend an alarm while an alarm image is dis- played, ALM SUSPENDED will not appear on the moni- tor. Reset the alarm, and then suspend it again. ■Resetting the Alarm Inputs There are two alarm reset functions: •Alarm reset (resetting the alarm inputs according to the input order) •Alarm all reset (resetting all the alarm inputs) ● Alarm Reset 1. Select a monitor which displays ALARM. 2. When more than one alarm signal has been input, the second earliest alarm image appears on the monitor, after the current alarm image is reset. 3. To reset all the alarms, repeat steps 1 and 2. The moni- tor, the LED display and the indicator will change as fol- lows: ALARMnn will disappear from the monitor. The LED display will return to the state before the alarm input. The alarm indicator will go out. The CAM indicator will return to the state before the alarm input. Note:When more than one alarm is input and they are associated with the same monitor, they will be reset one by one. ● Alarm All Reset T&D CAM IDEVENT AUX1 ON AUX1 OFFSTILL ALL RESET RESET TOUR SEQ Alarm input 1Alarm input 5Alarm input 2 • Description about alarm reset Monitor 1 Matrix switcher ALARM01* ALARM05* ALARM02 ALL RESET RESET ALL RESET RESET Monitor 1 Time SHIFT PAUSE NEXT PAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL ALL RESET RESET TOUR SEQ MON LOCK DEF OMON (ESC) T&D CAM MON STATUSALL ALM H VLD MULTI SCRE SEQUENCE AUX2 OEL-ZOOM AUX1 OSTILL SHIFT REW/FF STEP GROUP SEQ PAUSE SUSPEND ALL RESET ACKRESET TOUR SEQ PREVNEXT OSD PLAYPAUSE ALM SUSPENDED
104 MULTIPLEXER OPERATIONS Multiplexer board WJ-SXB151 is an optional board. It enables multiscreen display, electronic zooming, still pic- ture and multiscreen sequence. It also enables the operation of Digital Disk Recorder WJ- HD100 Series or time-lapse VCR, when connected to them. Note:Before the use, it is necessary to install the Multiplexer board in the matrix switcher and config- ure the system through SETUP MENU and WJ- SX150 Administrator Console. [Refer to p. 34 Installing the Multiplexer Board, p.52 WJ-SX150 SETUP MENU (OSD), and p. 64 WJ-SX150 ADMIN- ISTRATOR CONSOLE.] ■Monitoring the Camera Picture ●Multiscreen Segment Switching Refer to p. 117 Multiscreen Segment Switching for details. ●Multiscreen Sequence Camera images are switched automatically in a sequence mode. The sequence mode (QUAD, 3+1, 8+1) is configurable through WJ-SX150 Administrator Console. (Refer to p. 82 Sequence Mode of Multiplexer Mode for details.) 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) The monitor number and camera number will appear on the LED display. 2. Press the RECORDER button. (Refer to p. 116 Recorder Mode.) The system will enter the recorder mode. 3. Press the button 7 while holding down the SHIFT but- ton. A sequence of multiscreen pictures is displayed according to the WJ-SX150 Administrator Consoles configuration. 4. To cancel the sequence, press the button 0 while hold- ing down the SHIFT button. Note:The sequence mode can also be cancelled by press- ing a numeric button (corresponding one to the monitor number), then the CAM (SET) button. ●Still Playback Spot Picture The spot picture is changed into the still picture. 1. Select the desired monitor and camera number. (Refer to p. 90 Monitor Selection and Camera Selection.) The monitor number and camera number will appear on the LED display. 2. Press the RECORDER button. (Refer to p. 116 Recorder Mode.) The system will enter the recording mode. 3. Press the PLAY button. (Refer to p. 117 Normal Playback.) The system will enter the playback mode. 4. Select a camera channel by pressing a numeric button and then pressing the CAM (SET) button. The selected camera image will be displayed in a spot picture. 5. Press the button 1 while holding the SHIFT button. The selected camera image will change into the still picture. 6. To cancel the still picture, press the button 1 while hold- ing down the SHIFT button again. Note:Still picture is not available while zooming is acti- vated. ●Still Multiscreen Picture Still pictures can also be displayed in a multiscreen. 1. Select the desired monitor and camera number. (Refer to p. 90 Monitor Selection and Camera Selection.) The monitor number and camera number will appear on the LED display. 2. Press the RECORDER button. (Refer to p. 116 Recorder Mode.) The system will enter the recorder mode. 3. Press the numeric button corresponding to the camera number. 4. Press the button 1 while holding down the SHIFT but- ton. The selected camera image will change into the still picture. STILL and the camera title alternately blinks on the monitor. 5. To cancel the still picture, press the button 1 while hold- ing down the SHIFT button again. Notes: •“STILL” does not appear when the still display is set to OFF. •When you skip Step 3 and do Step 4, all the channels displayed in the multiscreen segments will be changed into the still pictures.
105 ●Electronic Zooming (EL-ZOOM) Playback spot pictures can be electrically zoomed. 1. Select the desired monitor. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the RECORDER button. (Refer to p. 116 Recorder Mode.) The system will enter the recorder mode. 3. Press the PLAY button. (Refer to p. 117 Normal Playback.) The system will enter the playback mode. 4. Select a camera channel by pressing a numeric button and then pressing the CAM (SET) button. The selected camera image will be displayed in a playback spot pic- ture. 5. Press the button 4 while holding down the SHIFT but- ton. “+” sings will appear on the image. 6. To move the “+” signs within the picture, move the joy- stick. 7. Press the button 4 while holding down the SHIFT but- ton. The area surrounded by the “+” signs will be zoomed up. 8. To move the zoom area, move the joystick. 9. To cancel the zooming, press the button 4 while holding down the SHIFT button again. Note:Still picture is not available while zooming is acti- vated.
108 WHEN USING A PS·DATA SYSTEM CONTROLLER This manual describes the operating procedures which are specifically related to WJ-SX150. For the basic operating procedures such as log-in/log-out, camera selection, and camera control, etc., refer to the system con- trollers operating instructions. The following are different from the terminal mode when you use the system controller via the PS·Data protocol. •Camera selection, camera control, camera site accessories control are in accordance with the PS·Data System operating procedures. Refer to the system controllers operating instructions. •You cannot reset an alarm one by one per monitor. However, you can reset all the alarms at a time (ALL RESET). •You cannot acknowledge an alarm. •You cannot use the auto log-in function of the unit. To use this function, use a terminal-mode system controller. •You cannot use the auto log-out function of the unit. •You cannot move the clock, camera title, event, and/or monitor status display with a PS·Data controller. Use a terminal- mode system controller. •Operators using the PS·Data system controller have the highest priority to all those using the terminal-mode system con- trollers. •PS·Data doesn’t support user-management, and you cannot configure the PS·Data operator registration neither through SETUP MENU nor WJ-SX150 Administrator Console. Notes: •When you select a monitor with a PS·Data system controller, you might enter its number as you do in the terminal mode. However, the matrix switcher regards a monitor as a unit, you need to select it by the unit number. (Refer to p. 109.) •This unit is counted as 4 PS·Data units. Confirm the total number of the PS·Data units in your system. (Up to 16 PS·Data units are available.)
109 Refer to the system controller’s operating instructions before you login the system. After the log-in procedure, the following operations are available to control the system. The operation begins with selecting a monitor, then the selected camera appears the active monitor. ■ Monitor Selection Unit addresses are given to each monitor. Rotary SW Mon 1 Mon 2 Mon 3 Mon 411234 The following is how to select a monitor. 1. Press the numeric button(s) to select the desired moni- tors unit address. 2. Press the UNIT button. The selected monitor will be activated. ■ Priority Lock You can apply or release priority lock by entering the func- tion code. Monitor display is the same as those of terminal mode. (Refer to p. xx for the illustrations.) 1. Select the desired monitor. (Refer to Monitor Selection). 2. Press the SHIFT button, and enter 101 by pressing the numeric buttons. 3. Press the FUNCTION button. The function will be exe- cuted. If the priority lock mode is selected, the monitor number will inversely appear on the active monitor. 4. To release the priority lock, do steps 2 and 3 again. Note:This function will prevent operators in the terminal mode from gaining control of a monitor. However, oper- ators via the PS·Data protocol can still gain control. MONITOR CONTROL
110 ■ Tour Sequence The following functions are available if a tour sequence has been previously configured through SETUP MENU or WJ- SX150 Administrator Console. Any tour sequence can be assigned to any monitors. 1. Select the desired monitor. (Refer to p. 109 Monitor Selection.) 2. To select the desired tour sequence number, press the numeric buttons. 3. Press the SEQ button to run the tour sequence in the forward direction on the active monitor. 4. Press the SEQ PAUSE button to pause a tour sequence on the active monitor. A series of camera picture appear in pause on the mon- itor screen for the specified dwell time. 5. Press the SEQ PAUSE button again to restart a tour sequence forward from the next step that was previous- ly paused by pressing the SEQ PAUSE button. 6. Press the SHIFT button, and then press the + button to move the sequence one frame to the next step from the step that was previously paused by pressing the PAUSE button. Press the SHIFT button, and then press the - button to move the sequence one frame to the previous step from the step that was previously paused by pressing the PAUSE button. 7. Select a camera (refer to the system controllers operat- ing instructions) to stop the sequence. The monitor will return to the spot mode. ■ Group Sequence The following function is available only if a group sequence has been previously established in WJ-SX150 Administrator Console. The group sequence has ID numbers. Group 1 is 17, Group 2 is 18, Group 3 is 19, and Group 4 is 20. As described earlier, a group sequence determines the assignment of monitors and cameras. Therefore, monitor selection is not required. 1. Press the numeric buttons to select a desired group sequence ID number, then press the SEQ button. 2. Press the SEQ button to run a group sequence forward on the assigned monitors. 5. Press the SEQ PAUSE button again to restart a tour sequence forward from the next step that was previous- ly paused by pressing the SEQ PAUSE button. 6. Press the SHIFT button, and then press the + button to move the sequence one frame to the next step from the step that was previously paused by pressing the PAUSE button. Press the SHIFT button, and then press the - button to move the sequence one frame to the previous step from the step that was previously paused by pressing the PAUSE button. 7. Select a camera (refer to the system controllers operat- ing instructions) to stop the sequence. The monitor will return to the spot mode. RUNNING SEQUENCE
111 The procedure described below lets you determine on-screen display (OSD) items, such as camera title, clock and status, on and off on the active monitor screen. Before controlling each item, monitor selection is necessary. (Refer to p. 109 Monitor Selection.) 1. Press the SHIFT button, and then press the numeric buttons corresponding to the function code. (Refer to the table.) 2. Press the FUNCTION button. The function will be executed. Notes: •Alarm History Table doesnt have a function code. When displaying the table, press the ALM RECALL button instead of the steps 1 and 2 above. OSD will appear on the LED display, and the ALARM HISTORY table will appear on the active monitor. •You cannot control OSD display position. MONITOR DISPLAY CONTROL Function CodeController Status Note Displaying the clock 104 Pressing again will hide the display. Displaying the camera title 105 Pressing again will hide the display. Displaying the event 106 Pressing again will hide the display. Displaying the monitor status107 Pressing again will hide the display. Displaying all the items 19 Pressing again will hide the display. Displaying System Status 102 OSD appears on the LED. Pressing again will return to the normal display. Displaying Video Loss History 103 OSD appears on the LED. Pressing again will return to the normal display.
112 ■Resetting All the Alarm Inputs You can reset all the alarm input signals at a time. 1. Select a monitor which displays ALARM. (Refer to the figure on p. 102.) 2. Press the SHIFT button, and then press the ALL RESET button. All the alarms will be reset. Then, the LED display and indicators will return to the state before the alarm input. Note:You cannot reset the alarm input signals one by one. ■Suspending All the Alarm Inputs Use this function when you do not want to be disturbed by an alarm input, for example, during the setup procedures. 1. To suspend all the alarm input signals, press the SHIFT button., and then press the SUSPEND button. The indicator beside the button will light up and ALM SUSPENDED will appear on the monitor. (Refer to the figure on p. 103.) 2. To cancel alarm suspension, do Step 1 again. Notes: •The alarm suspension is applied to all system units, not to a selected one. •An alarm which was input before the suspension will continue to operate. ■Alarm Mode When alarm (sensor) is accepted, the matrix switchers operation mode changes into the alarm mode. Then, the system operates as follows: •The camera image (alarm image) appears on the moni- tor. In the factory default setting, the alarm inputs 1 to 16 are associated with the same-numbered camera input connectors. All the video output signals are sent to Monitor 1. For example, when the alarm (sensor) con- nected to the alarm input 1 becomes active, the camera input connector 1’s image appears on Monitor 1. •ALARMnn appears on the monitor. The display indicates the image is input through the alarm nn (nn is the alarm number). When more than one alarm signal input has been accepted, ALARMnn* appears on the monitor. •The alarm indicator will blink. •Alarm output signals are supplied from Alarm Output 1 to 4 (#10, 11, 23 and 24) of the ALARM port (25-pin D- sub connector) at the rear panel. Alarm Output 1 to 4 is associated with MONITOR OUT 1 to 4. For example, when an alarm input signal is activated on MONITOR OUT 1, the unit supplies Alarm Output 1 to Monitor 1. •The monitor and alarm number will appear on the LED display. At the same time, the alarm indicator will blink, the monitor indicator will light up, and the camera indi- cator will go out. Notes: •The association of the alarm inputs with cameras and monitors are changeable in SETUP MENU or WJ-SX150 Administrator Console. (Refer to p. 56 or p. 74.) •Alarm input will be automatically reset in 30 seconds. The auto-recovery time is configurable through SETUP MENU or WJ-SX150 Administrator Console. ■Operation during an Alarm Mode While an alarm mode is active, you can do the following: •Resetting all the alarm inputs (ALL RESET) •Suspending all the alarm inputs (ALM SUSPENDED) ALARM CONTROL
113 This section will describe what you should take notice when using a PS·Data system controller. The same descriptions as the system controller’s operating instructions are not mentioned here. Refer to them. ■Controlling the Unit with a PS·Data System Controller 1. Before operating the recorder, it is necessary to enter the recorder mode. (Refer to p. 124 or p. 125.) 2. Enter the desired function code (refer to the diagram) and press the FUNCTION button. MULTIPLEXER OPERATIONS (PS · Data)