145 ●Timer Event Daily Every Hour Minute Sunday Monday Tuesday Wednesday Thursday Friday Saturday Monthly Every Day# Tour Sequence Tour# Spot Camera Preset Position#Every Schdule Mode Weekly Monitor# Camera# Action ●Camera Auto Cleaning ●Daylight Saving Time Daily Every Hour Minute Sunday Monday Tuesday Wednesday Thursday Friday Saturday Monthly Every Day# Cam #1 Cam #9 Cam #13 Cam #2 Cam #10 Cam #14 Cam #3 Cam #11 Cam #15 Cam #4 Cam #12 Cam #16 Schdule Mode Weekly Cam #5 Auto Cleaning Camera Cam #8 Cam #6 Cam #7 Every Start EndStart End
146 ●Alarm Event ALM# Monitor# Camera# / Tour sequence# Preset position# 109 8 7 6 5 4 3 2 1 11 12 13 14 15 16 ●Alarm Port Alarm # Alarm Port 1N.O./N.C./Time 2N.O./N.C./Time 3N.O./N.C./Time 4N.O./N.C./Time 5N.O./N.C./Time 6N.O./N.C./Time 7N.O./N.C./Time 8N.O./N.C./Time 9N.O./N.C./Time 10 N.O./N.C./Time 11 N.O./N.C./Time 12 N.O./N.C./Time 13 N.O./N.C./Time 14 N.O./N.C./Time 15 N.O./N.C./Time 16 N.O./N.C./Time ●Alarm Mode Alarm Mode Dwell Alarm Input Camera Site Alarm OFF / ON / REC only OFF / ON / REC only OFF / ON / REC only OFF / ON / REC only Sequence Mode sec. sec.Alarm Port Serial Port Mux Motion Det OFF Hold Mode Auto Reset Time
147 ●Operator Registration ●Level Table TimerPassword ID Operator# Level PriorityCamera Access 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Camera Access 1: View & Control 2: View Only 3: Prohibited 16 12 3 4567891011 12 13 14 15 16 ——— 11—— — — — — — ————————— Control Level 1 Level 2 Level 3 SX150 Setup Camera Setup Alarm History Display Video Loss History Display System Status Display Single Alarm Reset All Alarm Reset Alarm Suspend Camera View Call Sequence Program Preset Position Camera Control Recorder Control Recorder Setup OSD Control ●Monitor Selection Monitor 1 Monitor 2 Monitor 3 Monitor 4 Controller 1(KB1) Controller 2(KB2) Controller 3(KB3) Controller 4(KB4)OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG OK / NG PC OK / NG OK / NG OK / NG OK / NG
148 ●Camera Title Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Cam 6 Cam 7 Cam 8 Cam 9 Cam 10 Cam 11 Cam 12 Cam 13 Cam 14 Cam 15 Cam 16 Camera ID (Up to 20 characters) ●Auto Log-in/Log-out ●Cable Compensation/VD2 Minute(s) DATA 1 DATA 1 DATA 2 DATA 2 DATA 3 DATA 3 DATA 4 DATA 4Auto Log-in Auto Log-out Camera # Cable Compensation VD2 DATA Cam 1S / M / L ON / OFF ON / OFF Cam 2S / M / L ON / OFF ON / OFF Cam 3S / M / L ON / OFF ON / OFF Cam 4S / M / L ON / OFF ON / OFF Cam 5S / M / L ON / OFF ON / OFF Cam 6S / M / L ON / OFF ON / OFF Cam 7S / M / L ON / OFF ON / OFF Cam 8S / M / L ON / OFF ON / OFF Cam 9S / M / L ON / OFF ON / OFF Cam 10S / M / L ON / OFF ON / OFF Cam 11S / M / L ON / OFF ON / OFF Cam 12S / M / L ON / OFF ON / OFF Cam 13S / M / L ON / OFF ON / OFF Cam 14S / M / L ON / OFF ON / OFF Cam 15S / M / L ON / OFF ON / OFF Cam 16S / M / L ON / OFF ON / OFF
149 ●Data Port RS485 Port Protocol Baud Rate RS485 485 CAM bps DATA 1 485 CAM/CU360C bps DATA 2 485 CAM/CU360C bps DATA 3 485 CAM/CU360C bps DATA 4 CU360C/PS •Data bps sec. Logout TimeRS485 Camera Daisy PS •Data mode (for DATA 4) 12345678910111213141516 sec. Alarm Data Wait Time Group Address ●Multiplexer Multi Monitor Out Still Display Border Color Quad Shift Secret View Sequence Mode Quad / 3+1 / 8+1 s REC Out (Normal) REC MODE EXT INT Fields Title Display Clock Display
150 REC Out (Alarm) REC MODE EXT Cam GROUP Cam Cam CamINT Fields Dynamic REC OFF / ALM-PRI / ALM-ONLY / GROUP ALM 1 ALM 2 ALM 3 ALM 4 ALM 5 ALM 6 ALM 7 ALM 8 ALM 9 ALM 10 ALM 11 ALM 12 ALM 13 ALM 14 ALM 15 ALM 16 System Camera SW Loss Dummy Black Multiplexer Board Camera Title Cam1 Cam2 Cam3 Cam4 Cam5 Cam6 Cam7 Cam8 Cam9 Cam10 Cam11 Cam12 Cam13 Cam14 Cam15 Cam16
151 Power Source: 120 V AC, 60 Hz Power Consumption: 60 W Camera Input (1 to 16): 1.0 V[p-p]/75 Ωcomposite video signal 0.5 V[p-p]/75 Ωdata signal and 2.5 V[p-p]/75 Ωvertical timing pulse multiplexed Camera Output (1 to 16): 1.0 V[p-p]/75 Ωcomposite video signal Monitor Output (1 to 4): 1.0 V[p-p]/75 Ωcomposite video signal External Input: 1.0 V[p-p]/75 Ωcomposite video signal External Output: 1.0 V[p-p]/75 Ωcomposite video signal RS-485 (Camera) Port: RS-485 6-conductor modular jack Data Port: RS-485 6-conductor modular jack Alarm Port: 25-pin D-sub connector Serial Port: 9-pin D-sub connector Camera Switching Input: RCA pin jack Ambient Operating Temperature: –10 °C to +50 °C (14 °F to 122 °F) Ambient Operating Humidity: Less than 90 % Dimensions: 420 mm (W) X 88 mm (H) X 350 mm (D) [16-9/16 (W) X 3-7/16 (H) X 13-3/4 (D)] Weight: 6 kg(13.2 lbs.) SPECIFICATIONS Rack Mounting Bracket ................................... 2 pcs. Screws (M4 x 10) ............................................ 4 pcs. Power Cable .................................................... 1 pc. CD-ROM .......................................................... 1 pc. STANDARD ACCESSORIES
NM0102-4112 V8QB5945EN Printed in Japan PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010 PANASONIC SALES COMPANY DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO INC. San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina, P.R. 00985 (809)750-4300Panasonic Digital Communications & Security Company Unit Company of Matsushita Electric Corporation of America Security Systems www.panasonic.com/cctv Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Zone Office Eastern:One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Central:1707 N.Randal Road, Elgin, IL 60123 (847) 468-5205 Western:6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 2002 © Matsushita Communication Industrial Co., Ltd. All rights reserved.