    Alarm Group
    REC Mode:Select the desired setting by clicking on
    the radio button.
    EXT:Select this to gen-lock the unit during the alarm
    recording.
    INT:Select this if the asynchronous unit is connected to
    the unit. When it is activated, the drop-down menu
    becomes also active so that you can select the
    desired normal recording rate. 002, 004 to 128
    (field) are selectable.
    The factory default setting is EXT.
    DYNAMIC REC:Select the desired setting by clicking
    on the drop-down menu.
    ALM-PRI:Select this to give recording priority to the
    camera channel with the alarm input.
    ALM-ONLY:Select this to record the images from the
    alarm-associated camera channel.
    GROUP:Select this to give recording priority to a group
    of up to 4 camera channels associated to the alarm
    input. When you select this, the Group Setting but-
    ton becomes active. By pressing the button, the
    Mux Alarm Group window will be displayed so that
    you can configure the ALM 1 to 16 parameters.
    (Refer to Mux Alarm Group.)
    OFF:Select this to deactivate the alarm priority mode.
    The factory default setting is OFF.
    • System Group
    Camera SW Loss:Select the desired setting by click-
    ing on the drop-down menu.
    ON:“CAM SW LOSS” will blink on the associated moni-
    tor when loss of the camera switching pulse is
    detected. 
    OFF:“CAM SW LOSS will not appear on the monitor.
    The factory default setting is ON.
    Dummy Black:Select the desired setting by clicking
    on the drop-down menu.
    ON:The black image will be displayed for a camera
    channel that is not connected to the camera.
    OFF:The camera channel will be skipped in the
    sequence/spot mode.
    The factory default setting is ON.(Save Exit) button
    Saves the configuration and closes the Multiplexer Mode
    window.
    (Cancel Exit) button
    Cancels the configuration and closes the Multiplexer Mode
    window.
    ●Mux Alarm Group
    This is a submenu of the Multiplexer window. In this win-
    dow, up to 4 cameras are given recording priority for each
    alarm input.
    •Click a drop-down menu to assign the camera numbers
    (1 to 16) to each alarm input (ALM 1 to 16). The factory
    default setting is same as the illustration.
    •To configure ALM 9 to 16, click on the ALM 9 – 16 tab.
    (Save Exit) button
    Saves the configuration and closes the FS Board Alarm
    Group window.
    (Cancel Exit) button
    Cancels the configuration and closes the FS Board Alarm
    Group window. 
    						
    							84
    ●Multiplexer Title
    ●How to Display
    To display this window, click on the  (Multiplexer Title)
    button in the main window (p. 65.)
    ●How to Display
    Note:This window can be displayed only when Yes is
    selected in the Recorder window. (Refer to p. 66.)
    ●Parameters
    The factory default settings are same as the illustration.
    (The text box covered with the cursor is “C”.)
    To edit the desired camera’s title, click on the associated
    button (Cam 1 to Cam 16).
    The subsequent editing procedure is the same as Camera
    Title. (Refer to p.79.)
    Notes:
    The characters available here are the following:
    ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrs
    tuvwxyz0123456789!#$%&()*+,-
    ./:;¨=Æ?oÄÜÖÆÑÃØäüöæñãø
    •Up to 8 alphanumeric characters are available for the
    multiplexer board camera title.
    •You cannot edit a user font character.
    (Save Exit) button
    Saves the configuration and closes the Multiplexer Board
    Camera Title window.
    (Cancel Exit) button
    Cancels the configuration and closes the Multiplexer Board
    Camera Title window.
    ■Select Setup Data File
    The setup file is selectable by pressing this button.
    For example, this function will be used when making a new
    setup file with the factory default setting or configuring an
    existing setup file.
    Refer to the operating instructions of Windows
    ®for details
    of how to copy a data.
    ●How to Display
    To display this window, click on the  (File Open) button
    in the main window (p. 65).
    ●Parameters
    The location, name and type of the setup file appear in this
    window.
    File Name Input Area:Displays the selected files
    name. A new file (a setup file with the factory default
    setting) will be made when entering a new name.
    Open button: Opens the selected file.
    Cancel button:Cancels the operation and closes the
    Select Setup Data File dialog box. 
    						
    							85
    ■Account Manager
    This window configures the parameters of the operators
    who can control WJ-SX150 Administrator Console: the reg-
    istration, edit and deletion of an operator.
    The window soon after opening
    The window during the edit
    ●How to Display
    To display this window, click on the  (Account
    Manager) button in the main window (p. 65).
    Note: Register at least one operator with level 1. If there is
    no level 1 operator, the configuration of WJ-SX150
    Administrator Console will become impossible.
    ●Parameters
    • Accounts Group
    The registered operator names appears. To display the
    operator information in the Account Record group, click on
    the name.
    You can configure up to 16 account records.
    • Account Record Group
    Name:The operator name is displayed.
    Password:The password is displayed as *****. The
    entered password is displayed here during the edit.
    Level:Select the operator level.
    (OK) button
    Closes the Account Manager window.
    (Add Account) button
    To register a new operator, click on this button. The
    Registration window will appear.
    (EDIT) button:To configure the operator information,
    click on this button.
    (DELETE) button
    To delete the operator selected in the Accounts group,
    click on this button.
    (Save Exit) button
    Saves the configuration and closes the Account Manager
    window.
    (Cancel Exit) button
    Cancels the configuration and closes the Account Manager
    window.
    ●Edit Account Manager
    Add a Registration Operator
    1. Click on the  button.
    2. Enter the name in the Name box and the password in
    the Password box.
    Name:Up to 20 alphanumeric characters
    Password:Up to 20 alphanumeric characters
    3. Click on the ▼button to select the level.
    4. Click on the  (Save exit) button.
    The configuration will be saved and the Registration
    window will close.
    To cancel the configuration, click on the  (Cancel
    exit) button.
    Note:You can register up to 16 accounts (operators).
    Edit a Registration Operator
    1. Click on the registration operators name in the
    Accounts group.
    2. Click on the  (EDIT) button.
    3. Edit the desired parameters.
    4. Click on the  (Save exit) button.
    The configuration will be saved and the Registration
    window will close.
    To cancel the configuration, click on the  (Cancel
    exit) button.
    Delete a Registration Operator
    1. Click on the registration operators name in the
    Accounts group.
    2. Click on the  (Delete) button.
    3. Click on the  (Save exit) button.
    Note:If deleting all level 1 operators, the configuration of
    WJ-SX150 Administrator Console will become impossi-
    ble. 
    						
    							86
    ■Communication Port
    This window configures the PCs usable communication
    port number and its baud rate (communication speed).
    ●How to Display
    To display this window, click on the  (Communication
    port) button in the main window (p. 65).
    ●Parameters
    • Parameter Group
    Com:Select the PCs communication port for the con-
    nection to the unit.
    Baud Rate:Select the desired baud rate (communica-
    tion speed). 4800, 9600, 19200 or 38400 bps is
    selectable.
    The factory default setting is 38400 bps.
    • Fixed Parameter Group
    The data bit (8 bit), parity (none), and stop bit (1 bit) are
    displayed.
    Note:These parameters are fixed.
    (Save Exit) button
    Saves the configuration and closes the Communication Port
    window.
    (Cancel Exit) button
    Cancels the configuration and closes the Communication
    Port window. 
    						
    							87
    OPERATING PROCEDURES
    (TERMINAL MODE) 
    						
    							88
    LOG-IN AND LOG-OUT
    Before starting the following procedures, all system compo-
    nents must be turned on.
    The following procedures are applicable when the system
    controller is connected to the unit.
    ■ Log-in
    This operation is skipped when the auto log-in is set to ON.
    (Refer to p. 89.)
    1. Turn on the power switches of all system components. 
    The OPERATE indicator will light up.
    2. To turn on the power of the system controller, connect
    the AC adapter to the AC outlet.
    The LINK indicator lights up and NO USER appears
    on the LED display of the system controller.
    3. To select your registered operator ID number (1 to 16,
    up to 2 digits), press the numeric buttons, then press
    the CAM (SET) button.
    The underline appears on the LED display of the con-
    troller.
    The factory default setting is 150.
    4. To select your registered password (up to 5 digits),
    press the numeric buttons, then press the CAM (SET)
    button.
    The factory default setting is 150.
    If the operator ID and password are correct, READY
    will appear on the LED display.Note:If an operator ID or password error occurs, the
    PROHIBITED indicator on the controller will blink
    and NO ACC will blink on the LED display for
    about 3 seconds. Then NO USER appears on the
    LED display. Return to step 3 and select your oper-
    ator ID.
    MON LOCK
    DEF ON
    WIPER
    DEF OFFMON (ESC)
    T&D CAM ID
    MON STATUSALLEVENT
    ALM H VLD H SYS S
    CAM (SET)
    MULTI SCREEN SEL
    SEQUENCE
    AUX2 ON AUX2 OFFEL-ZOOM
    AUX1 ON AUX1 OFFSTILL
    Note:If the auto log-in is set to ON, any operator can login
    automatically. After the controller is turned on, AUTO
    appears on the LED display for approximately 2 sec-
    onds, then READY automatically appears. 
    						
    							89
    ■ Log-out
    This operation is skipped when the auto log-out is set to
    ON. 
    This function is used when an operator leaves the controller
    or no longer requires access to the system.
    1. To logout from the system press the CLEAR button
    while holding down the SHIFT button.
    NO USER appears on the LED display of the con-
    troller.
    Notes:
    •If you want to save the power consumption, discon-
    nect the PC plug from the controller, and remove
    the AC adapter from the AC outlet.
    •If the auto log-out is set to ON, any operator can
    logout automatically if no operation takes place for
    a specific time. NO USER automatically appears
    on the LED display.
    •The time to logout is configurable through WJ-
    SX150 Administrator Console. (Refer to p. 77 Auto
    Login/Logout.)
    SHIFT
    CALL
    PRESET
    PROGRAM
    PRESET
    PAUSE
    TOUR SEQ
    NEXT
    AUTO PAN
    PAUSE
    CAM FUNC
    CLEAR
    LOG OUTMON LOCK
    DEF ON
    WIPER
    DEF OFFMON (ESC)
    T&D CAM ID
    MON STATUSALLEVENT
    ALM H VLD H SYS S
    CAM (SET)
    MULTI SCREEN SEL
    SEQUENCE
    AUX2 ON AUX2 OFFEL-ZOOM
    AUX1 ON AUX1 OFFSTILL
    ■ Auto Log-in
    If the auto log-in is set to ON, any operator can login auto-
    matically. After the controller is turned on, AUTO appears
    on the LED display for approximately 2 seconds, then
    READY automatically appears.
    Auto log-in is configurable through WJ-SX150 Administrator
    Console. (Refer to p. 77 Auto Login/Logout.)
    ■ Auto Log-out
    If the auto log-out is set to ON and no operation takes place
    for a specific time, any operator can logout automatically.
    NO USER automatically appears on the LED display. 
    Auto log-out and the time to logout are configurable
    through WJ-SX150 Administrator Console. (Refer to p. 77
    Auto Login/ Logout.) 
    						
    							90
    ■ Priority Lock
    ● Applying Priority Lock
    1. Select the desired monitor. (Refer to Monitor Selection).
    2. Press the MON (ESC) button while holding down the
    SHIFT button to toggle the priority lock mode on and off
    on the active monitor.
    If the priority lock mode is selected, the monitor number
    will inversely appear on the active monitor as shown in
    the figure.
    Note:This function will prevent operators with lower priority
    from gaining control of a monitor.
    However, higher or equal priority operators may still
    gain control of the monitor.
    M04
    SHIFT
    PAUSE
    TOUR SEQ
    NEXT
    PAUSE
    MON LOCK
    DEF ON
    WIPER
    DEF OFFMON (ESC)
    T&D CAM ID
    MON STATUSALLEVENT
    ALM H VLD H SYS S
    CAM (SET)
    MULTI SCREEN SEL
    SEQUENCE
    AUX2 ON AUX2 OFFEL-ZOOM
    AUX1 ON AUX1 OFFSTILL
    ● Releasing Priority Lock
    1. Select the desired monitor. (Refer to Monitor Selection.)
    2. Press the MON (ESC) button while holding down the
    SHIFT button to release the priority lock mode.
    The monitor number returns to the normal display on
    the active monitor. After the log-in procedure, the following operations are
    available to control the system.
    The operation begins with selecting a monitor, then the
    selected camera appears the active monitor.
    ■ Monitor Selection
    1. To select the desired monitor number (1 to 4), press the
    numeric button.
    2. Press the MON (ESC) button to execute the selection.
    The MONITOR indicator on the controller will light up
    and the selected monitor number will appear on the
    LED display of the controller.
    3. If the selected monitor number is not valid, the PROHIB-
    ITED indicator lights up and the number on the LED dis-
    play will blink for approximately  3 seconds.
    Return to step 1 and select a new monitor number.
    Note:The PROHIBITED indicator will blink if an opera-
    tor with higher priority is controlling the
    monitor.Control of the same monitor is denied to an
    operator with lower priority.
    MON LOCK
    DEF ON
    WIPER
    DEF OFFMON (ESC)
    T&D CAM ID
    MON STATUSALLEVENT
    ALM H VLD H SYS S
    CAM (SET)
    MULTI SCREEN SEL
    SEQUENCE
    AUX2 ON AUX2 OFFEL-ZOOM
    AUX1 ON AUX1 OFFSTILL
    MONITOR SELECTION AND CAMERA SELECTION 
    						
    							91
    ■ Camera Selection
    1. Select the desired monitor. (Refer to p. 90 Monitor
    Selection.)
    2. Press the numeric buttons to select the desired camera
    number (1 to 16).
    3. Press the CAM (SET) button.
    The selected cameras image will appear on the active
    monitor. The CAMERA indicator will light up and the
    selected camera number will appear on the LED dis-
    play on the controller.
    SETUP
    SHIFT
    REW/FF
    STEP
    GROUP SEQ
    PAUSE
    SUSPEND
    F1
    CAM SETUPALL RESET
    ACKRESET
    F2
    TOUR SEQ
    PREVNEXT
    STOP
    OSD
    RECORDER
    INDEX
    STOP PLAYPAUSE
    Note:If you select a wrong number, press the CLEAR
    button to clear the input.
    4. If the selected camera number is not valid, the PRO-
    HIBITED indicator and the number on the LED display
    will blink for about 3 seconds. 
    Return to step 2 and select a new camera number.
    5. To replace the currently selected camera with the next
    higher-numbered camera , press the NEXT button.
    6. To replace the currently selected camera with the next
    lower-numbered camera, press the PREV button. 
    Note:The PROHIBITED indicator will light up, if the
    camera is selected by an operator with higher prior-
    ity. Control of the same camera is denied to an
    operator with lower priority. 
    						
    							92
    Buttons and control for cameras or camera site accessories
    are located on the right side of the front panel of the system
    controller.
    Included are zoom control, focus control, iris control, preset
    and pan/tilt controls. 
    Normally, combination cameras equipped with the specific
    feature or a WV-RC100 or WV-RC150 Receiver are required
    to utilize these functions.
    Note:Refer to the cameras operating instructions whether
    to confirm that each function is available.
    ■ Lens Control
    This function is available when specified lens, with motor-
    ized zoom/ focus functions, is mounted on the camera, and
    the lens selection (DC/VIDEO) on the camera is set to DC.
    1. Select the desired monitor and camera. (Refer to p. 90
    Monitor Selection and p. 91 Camera Selection.)
    2. Press the FOCUS NEAR/FAR buttons while watching
    the monitor. The lens focus is adjusted to obtain a
    sharply focused image.
    To set the lens focus automatically, press these buttons
    simultaneously. 
    Pressing the top button of WV-CU360CJ can also set
    the lens focus automatically.
    3. Press the ZOOM WIDE/TELE buttons while watching the
    monitor. The lens iris is adjusted to obtain the desired
    image.
    Press the TELE button to bring an object optically clos-
    er. Press the WIDE button to widen the scene optically.Moving the zoom wheel controller of WV-CU360CJ can
    also adjust the lens zoom.
    4. Press the IRIS CLOSE/OPEN buttons to close/open the
    lens iris. The lens iris is adjusted by these buttons to
    obtain the proper image exposure.
    To reset to the factory default setting, press these but-
    tons simultaneously.
    ■ Pan/Tilt Control
    ● Manual Operation
    1. Select the desired monitor and camera. (Refer to p. 90
    Monitor Selection and p. 91 Camera Selection.)
    2. Move the joystick to move the pan/tilt head towards the
    desired direction.
    ● Auto Panning
    1. Select the desired monitor and camera. (Refer to p. 90
    Monitor Selection and p. 91 Camera Selection.)
    2. To activate the auto panning function of the selected
    camera, press the AUTO PAN button.
    3. To cancel the auto panning function, move the joystick.
    CAMERA CONTROL
    AUTO FOCUS
    NEARFA R
    FOCUS
    WIDE TELE
    ZOOM
    REC
    IRIS
    CLOSE OPEN
    AUTO IRIS
    UP
    LR
    DOWN
    AUTO PAN
    CAM FUNC
    Top button
    WIDE
    TELE
    Zoom wheel controller 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Matrix Switcher Wj Sx150 Operating Instructions