83 Alarm Group REC Mode:Select the desired setting by clicking on the radio button. EXT:Select this to gen-lock the unit during the alarm recording. INT:Select this if the asynchronous unit is connected to the unit. When it is activated, the drop-down menu becomes also active so that you can select the desired normal recording rate. 002, 004 to 128 (field) are selectable. The factory default setting is EXT. DYNAMIC REC:Select the desired setting by clicking on the drop-down menu. ALM-PRI:Select this to give recording priority to the camera channel with the alarm input. ALM-ONLY:Select this to record the images from the alarm-associated camera channel. GROUP:Select this to give recording priority to a group of up to 4 camera channels associated to the alarm input. When you select this, the Group Setting but- ton becomes active. By pressing the button, the Mux Alarm Group window will be displayed so that you can configure the ALM 1 to 16 parameters. (Refer to Mux Alarm Group.) OFF:Select this to deactivate the alarm priority mode. The factory default setting is OFF. • System Group Camera SW Loss:Select the desired setting by click- ing on the drop-down menu. ON:“CAM SW LOSS” will blink on the associated moni- tor when loss of the camera switching pulse is detected. OFF:“CAM SW LOSS will not appear on the monitor. The factory default setting is ON. Dummy Black:Select the desired setting by clicking on the drop-down menu. ON:The black image will be displayed for a camera channel that is not connected to the camera. OFF:The camera channel will be skipped in the sequence/spot mode. The factory default setting is ON.(Save Exit) button Saves the configuration and closes the Multiplexer Mode window. (Cancel Exit) button Cancels the configuration and closes the Multiplexer Mode window. ●Mux Alarm Group This is a submenu of the Multiplexer window. In this win- dow, up to 4 cameras are given recording priority for each alarm input. •Click a drop-down menu to assign the camera numbers (1 to 16) to each alarm input (ALM 1 to 16). The factory default setting is same as the illustration. •To configure ALM 9 to 16, click on the ALM 9 – 16 tab. (Save Exit) button Saves the configuration and closes the FS Board Alarm Group window. (Cancel Exit) button Cancels the configuration and closes the FS Board Alarm Group window.
84 ●Multiplexer Title ●How to Display To display this window, click on the (Multiplexer Title) button in the main window (p. 65.) ●How to Display Note:This window can be displayed only when Yes is selected in the Recorder window. (Refer to p. 66.) ●Parameters The factory default settings are same as the illustration. (The text box covered with the cursor is “C”.) To edit the desired camera’s title, click on the associated button (Cam 1 to Cam 16). The subsequent editing procedure is the same as Camera Title. (Refer to p.79.) Notes: The characters available here are the following: ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrs tuvwxyz0123456789!#$%&()*+,- ./:;¨=Æ?oÄÜÖÆÑÃØäüöæñãø •Up to 8 alphanumeric characters are available for the multiplexer board camera title. •You cannot edit a user font character. (Save Exit) button Saves the configuration and closes the Multiplexer Board Camera Title window. (Cancel Exit) button Cancels the configuration and closes the Multiplexer Board Camera Title window. ■Select Setup Data File The setup file is selectable by pressing this button. For example, this function will be used when making a new setup file with the factory default setting or configuring an existing setup file. Refer to the operating instructions of Windows ®for details of how to copy a data. ●How to Display To display this window, click on the (File Open) button in the main window (p. 65). ●Parameters The location, name and type of the setup file appear in this window. File Name Input Area:Displays the selected files name. A new file (a setup file with the factory default setting) will be made when entering a new name. Open button: Opens the selected file. Cancel button:Cancels the operation and closes the Select Setup Data File dialog box.
85 ■Account Manager This window configures the parameters of the operators who can control WJ-SX150 Administrator Console: the reg- istration, edit and deletion of an operator. The window soon after opening The window during the edit ●How to Display To display this window, click on the (Account Manager) button in the main window (p. 65). Note: Register at least one operator with level 1. If there is no level 1 operator, the configuration of WJ-SX150 Administrator Console will become impossible. ●Parameters • Accounts Group The registered operator names appears. To display the operator information in the Account Record group, click on the name. You can configure up to 16 account records. • Account Record Group Name:The operator name is displayed. Password:The password is displayed as *****. The entered password is displayed here during the edit. Level:Select the operator level. (OK) button Closes the Account Manager window. (Add Account) button To register a new operator, click on this button. The Registration window will appear. (EDIT) button:To configure the operator information, click on this button. (DELETE) button To delete the operator selected in the Accounts group, click on this button. (Save Exit) button Saves the configuration and closes the Account Manager window. (Cancel Exit) button Cancels the configuration and closes the Account Manager window. ●Edit Account Manager Add a Registration Operator 1. Click on the button. 2. Enter the name in the Name box and the password in the Password box. Name:Up to 20 alphanumeric characters Password:Up to 20 alphanumeric characters 3. Click on the ▼button to select the level. 4. Click on the (Save exit) button. The configuration will be saved and the Registration window will close. To cancel the configuration, click on the (Cancel exit) button. Note:You can register up to 16 accounts (operators). Edit a Registration Operator 1. Click on the registration operators name in the Accounts group. 2. Click on the (EDIT) button. 3. Edit the desired parameters. 4. Click on the (Save exit) button. The configuration will be saved and the Registration window will close. To cancel the configuration, click on the (Cancel exit) button. Delete a Registration Operator 1. Click on the registration operators name in the Accounts group. 2. Click on the (Delete) button. 3. Click on the (Save exit) button. Note:If deleting all level 1 operators, the configuration of WJ-SX150 Administrator Console will become impossi- ble.
86 ■Communication Port This window configures the PCs usable communication port number and its baud rate (communication speed). ●How to Display To display this window, click on the (Communication port) button in the main window (p. 65). ●Parameters • Parameter Group Com:Select the PCs communication port for the con- nection to the unit. Baud Rate:Select the desired baud rate (communica- tion speed). 4800, 9600, 19200 or 38400 bps is selectable. The factory default setting is 38400 bps. • Fixed Parameter Group The data bit (8 bit), parity (none), and stop bit (1 bit) are displayed. Note:These parameters are fixed. (Save Exit) button Saves the configuration and closes the Communication Port window. (Cancel Exit) button Cancels the configuration and closes the Communication Port window.
88 LOG-IN AND LOG-OUT Before starting the following procedures, all system compo- nents must be turned on. The following procedures are applicable when the system controller is connected to the unit. ■ Log-in This operation is skipped when the auto log-in is set to ON. (Refer to p. 89.) 1. Turn on the power switches of all system components. The OPERATE indicator will light up. 2. To turn on the power of the system controller, connect the AC adapter to the AC outlet. The LINK indicator lights up and NO USER appears on the LED display of the system controller. 3. To select your registered operator ID number (1 to 16, up to 2 digits), press the numeric buttons, then press the CAM (SET) button. The underline appears on the LED display of the con- troller. The factory default setting is 150. 4. To select your registered password (up to 5 digits), press the numeric buttons, then press the CAM (SET) button. The factory default setting is 150. If the operator ID and password are correct, READY will appear on the LED display.Note:If an operator ID or password error occurs, the PROHIBITED indicator on the controller will blink and NO ACC will blink on the LED display for about 3 seconds. Then NO USER appears on the LED display. Return to step 3 and select your oper- ator ID. MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL Note:If the auto log-in is set to ON, any operator can login automatically. After the controller is turned on, AUTO appears on the LED display for approximately 2 sec- onds, then READY automatically appears.
89 ■ Log-out This operation is skipped when the auto log-out is set to ON. This function is used when an operator leaves the controller or no longer requires access to the system. 1. To logout from the system press the CLEAR button while holding down the SHIFT button. NO USER appears on the LED display of the con- troller. Notes: •If you want to save the power consumption, discon- nect the PC plug from the controller, and remove the AC adapter from the AC outlet. •If the auto log-out is set to ON, any operator can logout automatically if no operation takes place for a specific time. NO USER automatically appears on the LED display. •The time to logout is configurable through WJ- SX150 Administrator Console. (Refer to p. 77 Auto Login/Logout.) SHIFT CALL PRESET PROGRAM PRESET PAUSE TOUR SEQ NEXT AUTO PAN PAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL ■ Auto Log-in If the auto log-in is set to ON, any operator can login auto- matically. After the controller is turned on, AUTO appears on the LED display for approximately 2 seconds, then READY automatically appears. Auto log-in is configurable through WJ-SX150 Administrator Console. (Refer to p. 77 Auto Login/Logout.) ■ Auto Log-out If the auto log-out is set to ON and no operation takes place for a specific time, any operator can logout automatically. NO USER automatically appears on the LED display. Auto log-out and the time to logout are configurable through WJ-SX150 Administrator Console. (Refer to p. 77 Auto Login/ Logout.)
90 ■ Priority Lock ● Applying Priority Lock 1. Select the desired monitor. (Refer to Monitor Selection). 2. Press the MON (ESC) button while holding down the SHIFT button to toggle the priority lock mode on and off on the active monitor. If the priority lock mode is selected, the monitor number will inversely appear on the active monitor as shown in the figure. Note:This function will prevent operators with lower priority from gaining control of a monitor. However, higher or equal priority operators may still gain control of the monitor. M04 SHIFT PAUSE TOUR SEQ NEXT PAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL ● Releasing Priority Lock 1. Select the desired monitor. (Refer to Monitor Selection.) 2. Press the MON (ESC) button while holding down the SHIFT button to release the priority lock mode. The monitor number returns to the normal display on the active monitor. After the log-in procedure, the following operations are available to control the system. The operation begins with selecting a monitor, then the selected camera appears the active monitor. ■ Monitor Selection 1. To select the desired monitor number (1 to 4), press the numeric button. 2. Press the MON (ESC) button to execute the selection. The MONITOR indicator on the controller will light up and the selected monitor number will appear on the LED display of the controller. 3. If the selected monitor number is not valid, the PROHIB- ITED indicator lights up and the number on the LED dis- play will blink for approximately 3 seconds. Return to step 1 and select a new monitor number. Note:The PROHIBITED indicator will blink if an opera- tor with higher priority is controlling the monitor.Control of the same monitor is denied to an operator with lower priority. MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL MONITOR SELECTION AND CAMERA SELECTION
91 ■ Camera Selection 1. Select the desired monitor. (Refer to p. 90 Monitor Selection.) 2. Press the numeric buttons to select the desired camera number (1 to 16). 3. Press the CAM (SET) button. The selected cameras image will appear on the active monitor. The CAMERA indicator will light up and the selected camera number will appear on the LED dis- play on the controller. SETUP SHIFT REW/FF STEP GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD RECORDER INDEX STOP PLAYPAUSE Note:If you select a wrong number, press the CLEAR button to clear the input. 4. If the selected camera number is not valid, the PRO- HIBITED indicator and the number on the LED display will blink for about 3 seconds. Return to step 2 and select a new camera number. 5. To replace the currently selected camera with the next higher-numbered camera , press the NEXT button. 6. To replace the currently selected camera with the next lower-numbered camera, press the PREV button. Note:The PROHIBITED indicator will light up, if the camera is selected by an operator with higher prior- ity. Control of the same camera is denied to an operator with lower priority.
92 Buttons and control for cameras or camera site accessories are located on the right side of the front panel of the system controller. Included are zoom control, focus control, iris control, preset and pan/tilt controls. Normally, combination cameras equipped with the specific feature or a WV-RC100 or WV-RC150 Receiver are required to utilize these functions. Note:Refer to the cameras operating instructions whether to confirm that each function is available. ■ Lens Control This function is available when specified lens, with motor- ized zoom/ focus functions, is mounted on the camera, and the lens selection (DC/VIDEO) on the camera is set to DC. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the FOCUS NEAR/FAR buttons while watching the monitor. The lens focus is adjusted to obtain a sharply focused image. To set the lens focus automatically, press these buttons simultaneously. Pressing the top button of WV-CU360CJ can also set the lens focus automatically. 3. Press the ZOOM WIDE/TELE buttons while watching the monitor. The lens iris is adjusted to obtain the desired image. Press the TELE button to bring an object optically clos- er. Press the WIDE button to widen the scene optically.Moving the zoom wheel controller of WV-CU360CJ can also adjust the lens zoom. 4. Press the IRIS CLOSE/OPEN buttons to close/open the lens iris. The lens iris is adjusted by these buttons to obtain the proper image exposure. To reset to the factory default setting, press these but- tons simultaneously. ■ Pan/Tilt Control ● Manual Operation 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Move the joystick to move the pan/tilt head towards the desired direction. ● Auto Panning 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. To activate the auto panning function of the selected camera, press the AUTO PAN button. 3. To cancel the auto panning function, move the joystick. CAMERA CONTROL AUTO FOCUS NEARFA R FOCUS WIDE TELE ZOOM REC IRIS CLOSE OPEN AUTO IRIS UP LR DOWN AUTO PAN CAM FUNC Top button WIDE TELE Zoom wheel controller