53 ●How to Display To display this menu on the monitor, move the cursor to 100 TIME & DATE in SETUP MENU by moving the joystick to D or C. ●Parameters You can move the cursor to each parameter by moving the joystick to Aor B. • Month Press the NEXT or PREV button to select the correct month. • Day Press the numeric buttons to enter it directly.
54 300 SEQUENCE TOUR NO. =1 STEP CAM PRE DWELL STEP CAM PRE DWELL 1 1 -- 2S 9 9 -- 2S 2 2 -- 2S 10 10 -- 2S 3 3 -- 2S 11 11 -- 2S 4 4 -- 2S 12 12 -- 2S 5 5 -- 2S 13 13 -- 2S 6 6 -- 2S 14 14 -- 2S 7 7 -- 2S 15 15 -- 2S 8 8 -- 2S 16 16 -- 2S 400 ALARM 410 ALARM MODE SEQUENCE / DWELL 2sec 420 ALARM EVENTOALARM INPUT 430 CAMERA OFF 440 ALARM PORT ONO 450 SERIAL PORT ON 460 MUX MOTION DET OFFO 440 ALARM INPUT(ALARM PORT) 1 N.O. 9 N.O. 2 N.O. 10 N.O. 3 N.O. 11 N.O. 4 N.O. 12 N.O. 5 N.O. 13 N.O. 6 N.O. 14 N.O. 7 N.O. 15 N.O. 8 N.O. 16 N.O. 500 CAMERA TITLE 2 of 2 CAM TITLE 9 C09 10 C10 11 C11 12 C12 13 C13 14 C14 15 C15 16 C16 700 SYSTEM 710 COMPENSATION/VD2/DATAO 720 RS485 CAMERAO 730 DATA4/PSD PORT SELECT PSD 740 PSD/HDR PORT SPEED 9600bps 750 SERIAL PORT SPEED 38400bps 760 EXT IN GENLOCK OFF 770 CAMERA CLEANING OFF 600 RECORDER 610 REDORDER CONTROL OFF 620 RECORDER UNIT ADDRESS 1 800 OPERATOR REGISTRATION OPERATOR NO.=01 ID =150 PASSWORD=***** PRIORITY=1 LEVEL =1 CAM01=VIEW&CONTROL CAM09=VIEW&CONTROL CAM02=VIEW&CONTROL CAM10=VIEW&CONTROL CAM03=VIEW&CONTROL CAM11=VIEW&CONTROL CAM04=VIEW&CONTROL CAM12=VIEW&CONTROL CAM05=VIEW&CONTROL CAM13=VIEW&CONTROL CAM06=VIEW&CONTROL CAM14=VIEW&CONTROL CAM07=VIEW&CONTROL CAM15=VIEW&CONTROL CAM08=VIEW&CONTROL CAM16=VIEW&CONTROL 900 MULTIPLEXER VCR REC MODE 910 ALARM EXT. 920 NORMAL EXT. 930 DYNAMIC REC OFF 940 DUMMY BLACK OFF 950 CAM SW LOSS ON 1000 MUX CAMERA TITLE CAM TITLE CAM TITLE 1 C01 9 C09 2 C02 10 C10 3 C03 11 C11 4 C04 12 C12 5 C05 13 C13 6 C06 14 C14 7 C07 15 C15 8 C08 16 C16 420 ALARM EVENT 2 of 2 ALM MON MODE 9 1 SPOT1 / PRE01 10 1 SPOT1 / PRE01 11 1 SPOT1 / PRE01 12 1 SPOT1 / PRE01 13 1 SPOT1 / PRE01 14 1 SPOT1 / PRE01 15 1 SPOT1 / PRE01 16 1 SPOT1 / PRE01 420 ALARM EVENT 1 of 2 ALM MON MODE 1 1 CAM01 / PRE-- 2 1 CAM02 / PRE-- 3 1 CAM03 / PRE-- 4 1 CAM04 / PRE-- 5 1 CAM05 / PRE-- 6 1 CAM06 / PRE-- 7 1 CAM07 / PRE-- 8 1 CAM08 / PRE-- 500 CAMERA TITLE 1 of 2 CAM TITLE 1 2 3 4 5 6 7 8 610 COMPENSATION/VD2/DATA CAM COMP VD2 DATA CAM COMP VD2 DATA 1 S ON ON 9 S ON ON 2 S ON ON 10 S ON ON 3 S ON ON 11 S ON ON 4 S ON ON 12 S ON ON 5 S ON ON 13 S ON ON 6 S ON ON 14 S ON ON 7 S ON ON 15 S ON ON 8 S ON ON 16 S ON ON 620 RS485 CAMERA CAM PORT CAM PORT 1 -- 9 -- 2 -- 10 -- 3 -- 11 -- 4 -- 12 -- 5 -- 13 -- 6 -- 14 -- 7 -- 15 -- 8 -- 16 -- Outside the U. S.: · Aug/21/2002... 21/08/2002 · D. S. T.... SUMMER TIME WJ-SX150 SETUP MENU x.xx/x.xx 100 TIME&DATE Aug/21/2002 10:55 AM 200 D.S.T. ON 300 SEQUENCE O 400 ALARMO 500 CAMERA TITLEO 600 RECORDERO 700 SYSTEMO 800 OPERATOR REGISTRATIONO 900 MULTIPLEXERO 1000 MUX CAMERA TITLEO
55 • Year Press the numeric button to enter the correct year. • TIME Press the numeric button to enter the correct time. • MINUTE Press the numeric button to enter the correct minute. • AM/PM Press the NEXT or PREV button to select the correct time. After the configuration, press the SETUP button while hold- ing down the SHIFT button. The configuration will be updat- ed when closing SETUP MENU. Notes: • Adjust the time and date when the clock display is differ- ent from the current one. • The clock display pattern is changeable with the setting in WJ-SX150 Administrator Console. (Refer to p. 77.) The factory default setting is Month/Day/Year. • The clock is automatically adjusted to 0 second of the set- ting time and date when closing SETUP MENU. • Hour system (12- hours or 24- hours) is changeable through WJ-SX150 Administrator Console.■D. S. T. (Daylight Saving Time) ●How to Display To display this menu on the monitor, move the cursor to 200 D. S. T. in SETUP MENU by moving the joystick to ▼or ▲. ●Parameters Select ON or OFF by pressing the NEXT or PREV buttons. ON:Daylight saving time is activated. OFF:Daylight saving time is deactivated. The factory default setting is ON. After the configuration, press the SETUP button while hold- ing down the SHIFT button. The configuration will be updat- ed when closing SETUP MENU. Note:The start/end date are configurable through WJ- SX150 Administrator Console. (Refer to p. 71.) ■SEQUENCE SETUP ●How to Display To display this menu on the monitor, move the cursor to 300 SEQUENCE in SETUP MENU by moving the joystick to ▼or ▲. Then, press the CAM (SET) button. The submenu appears on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. Press the numeric button(s) to enter a number. WJ-SX150 SETUP MENU x.xx/x.xx 100 TIME&DATE Aug/21/2002 10:55 AM 200 D.S.T. ON 300 SEQUENCE O 400 ALARMO 500 CAMERA TITLEO 600 RECORDERO 700 SYSTEMO 800 OPERATOR REGISTRATIONO 900 MULTIPLEXERO 1000 MUX CAMERA TITLEO 300 SEQUENCE TOUR NO. =1 STEP CAM PRE DWELL STEP CAM PRE DWELL 1 1 -- 2S 9 9 -- 2S 2 2 -- 2S 10 10 -- 2S 3 3 -- 2S 11 11 -- 2S 4 4 -- 2S 12 12 -- 2S 5 5 -- 2S 13 13 -- 2S 6 6 -- 2S 14 14 -- 2S 7 7 -- 2S 15 15 -- 2S 8 8 -- 2S 16 16 -- 2S
56 TOUR NO:Press the NEXT or PREV button to select the tour number. Or press the numeric button(s) to enter a number. STEP: This stands for a tour sequence step. CAM: This stands for a camera number. CAM 0 to 16 is selectable. CAM 0 deactivates the sequence step. The factory default setting is assigned to each step in numerical order (STEP 1 = CAM 1, STEP 2 = CAM 2, STEP 3 = CAM 3, STEP = 4, CAM 4, STEP 5 = CAM 5…) PRE: This stands for a camera’s preset position num- ber. 1 to 64 or - - is selectable. When the camera has no preset position, select - -. You can set - - by pressing the button 0. The factory default setting is - -. DWELL: This stands for the dwell time. 1 second to 30 seconds are selectable. If you enter 0, the sequence step will be skipped. The factory default setting is 2S for each step. After the configuration, press the MON (ESC) button. The monitor display will return to the previous menu. After all the configurations, press the SETUP button while holding down the SHIFT button. The configuration will be updated when closing SETUP MENU. Notes: •A preset position number is available only when a com- bination camera is selected for CAM. •The available preset position numbers differ among cameras. Refer to each cameras operating instruc- tions. ■ALARM SETUP ●How to Display To display this menu on the monitor, move the cursor to 400 ALARM in SETUP MENU by moving the joystick to ▼or ▲. Then, press the CAM (SET) button. The submenu appears on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. Press the numeric button(s) to enter a number. • ALARM MODE You can select an operation mode when alarm input signals are accepted by the unit. Notes: •The alarm mode is activated when alarm input signals are assigned to the same monitor through 420 ALARM EVENT or the Alarm Event (refer to p. 74) window. •While alarm is activated, you cannot operate the func- tions related to the multiplexer board. SEQUENCE:An alarm operation is replaced by anoth- er one after the dwell time (DWELL) ends. HOLD:An initial alarm operation is continued even after another alarm input is accepted. OFF: Select this when not using the alarm mode. The factory default setting is SEQUENCE. • DWELL This stands for the dwell time of a sequence during an alarm mode. 1 to 30 seconds are selectable. The factory default setting is 2 seconds. • ALARM EVENT This item is configurable in 420 ALARM EVENT. Move the cursor and press the CAM (SET) button. 420 ALARM EVENT will appear on the monitor. ALM:This stands for the alarm number. MON:This stands for the monitor number. MODE:This stands for the display mode of an alarm image. •CAMnn (nn is the camera number): Activates the spot camera when an alarm input is accepted. 400 ALARM 410 ALARM MODE SEQUENCE / DWELL 2sec 420 ALARM EVENT ALARM INPUT 430 CAMERA OFF 440 ALARM PORT ON O 450 SERIAL PORT ON 460 MUX MOTION DET OFFO 420 ALARM EVENT 1 of 2 ALM MON MODE 1 1 CAM01 / PRE-- 2 1 CAM02 / PRE-- 3 1 CAM03 / PRE-- 4 1 CAM04 / PRE-- 5 1 CAM05 / PRE-- 6 1 CAM06 / PRE-- 7 1 CAM07 / PRE-- 8 1 CAM08 / PRE-- 420 ALARM EVENT 2 of 2 ALM MON MODE 9 1 CAM09 / PRE-- 10 1 CAM10 / PRE-- 11 1 CAM11 / PRE-- 12 1 CAM12 / PRE-- 13 1 CAM13 / PRE-- 14 1 CAM14 / PRE-- 15 1 CAM15 / PRE-- 16 1 CAM16 / PRE--
57 OFF:An alarm input is not accepted via the ALARM port. The factory default setting is ON. Each alarm inputs polarity is configurable in 440 ALARM INPUT (ALARM PORT). Set ALARM PORT to ON or REC ONLY, and press the CAM (SET) button. 440 ALARM INPUT (ALARM PORT) will appear on the moni- tor. To select an alarm input polarity required for the ALARM port, press the PREV or NEXT button. N.O.:Selects Normally Open alarm contact. N.C.:Selects Normally Closed alarm contact. TIME:Enables the input for time adjustment. The factory default setting is N.O. Notes: •Use N.O. type master clock. •If TIME is selected, an alarm input terminal can adjust the clock by ±30 seconds with an N.O. type signal input. For example, when the clock time is between 00:59:30 and 01:00:30, it will be automatically adjusted to 01:00:00 by the master clock. After the configuration, press the MON (ESC) button. The monitor display returns to 400 ALARM SETUP. SERIAL PORT This stands for that an alarm input is accepted via the SERIAL port. The alarm-associated sequence/ spot image is displayed on a monitor, and alarm recording will start (if a recorder is connected to the unit). ON:The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY:Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images. Note:You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF:An alarm input is not accepted via the SERIAL port. The factory default setting is ON. •PRE: This item stands for the preset position num- ber of a CAMnn. Enter the desired preset position number when selecting a combination camera. When selecting another type of camera, select --. •TOURnn (nn is a tour sequence number): Executes a tour sequence when an alarm input is accepted. The factory default setting is the same as the two illustra- tions above. Notes: •MODE and PRE cannot be selected by pressing the numeric buttons. Press the NEXT or PREV button for selection. •PRE doesn’t appear when TOUR 1 to 16 is selected for MODE. •When selecting a camera without the preset position function, select - - for PRE. •When moving the joystick to ▼at the bottom of ALARM EVENT 1 of 2, the monitor will display 2 of 2 (the next page). •When moving the joystick to ▲at the top of ALARM EVENT 2 of 2, the monitor will display 1 of 2 (the previ- ous page). After the configuration, press the MON (ESC) button. The monitor display returns to ALARM SETUP. • ALARM INPUT CAMERA This stands for that an alarm input is accepted via the CAMERA IN connectors or the RS-485 ports. ON:The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit). REC ONLY:Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images. Note:You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF:An alarm input is accepted neither via the CAM- ERA IN connectors nor the RS-485 ports. The factory default setting is OFF. ALARM PORT This stands for that an alarm input is accepted via the ALARM port (25-pin D-sub connector at the rear panel). ON:The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY:Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images. Note:You cannot recover alarm-related operations from system controllers when REC ONLY is selected. 440 ALARM INPUT(ALARM PORT) 1 N.O. 9 N.O. 2 N.O. 10 N.O. 3 N.O. 11 N.O. 4 N.O. 12 N.O. 5 N.O. 13 N.O. 6 N.O. 14 N.O. 7 N.O. 15 N.O. 8 N.O. 16 N.O.
58 • MUX MOTION DET This menu appears only when the Multiplexer board is installed in the unit. This stands for that the unit’s motion detector is activat- ed when a camera detects the brightness-level change and transmit an alarm signal. ON:The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY:Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images. Note:You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF:An alarm input is not accepted by the motion detector. To configure where to activate the motion detector, set MUX MOTION DET to ON or REC ONLY, and press the CAM (SET) button. The live image will be displayed. Note:Black image will be displayed on the monitor if the currently selected channel has no camera con- nection. A “+” mark appears at the center of the monitor. The following is the setting procedure. 1. Move the cursor with the joystick to the desired area, and then press the CAM (SET) key. Setting point 1 is determined.2. Move the “+” mark to the desired area, and then press the CAM (SET) key. Setting point 2 is determined and the “+” mark will disappear. Then, the mark will appear again at the center of the monitor. The square, covered with Setting point 1 and 2, is showing the motion-detec- tion area. Note:White images will be displayed in the square if the currently selected channel has no camera connection. 3. To configure more motion-detection area, repeat Step 1 and 2. Up to 4 motion-detection areas are available. +Mark + Setting point + Setting point 1 Setting point 2 +
59 ■CAMERA TITLE ●How to Display To display this menu on the monitor, move the cursor to 500 CAMERA TITLE in SETUP MENUby moving the joystick to ▼or ▲. Then, press the CAM (SET) button. The submenu appears on the monitor. ●How to edit A camera title is composed of up to 20 characters. Each camera number is fixed and the subsequent 20 char- acters are editable. The characters available here are the following: ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrs tuvwxyz0123456789!#$%&()*+,-./:;=?•_(space) The factory default settings are same as the illustrations. 1. Edit the camera titles by pressing the NEXT or PREV buttons. The NEXT button toggles these characters in this order. The PREV button toggles these characters in a reverse order. Joystick and the CLEAR button are also usable for the edit. (Refer to p. 52 Displaying SETUP MENU for each use.) 2. After the configuration, press the MON (ESC) button. The monitor display will return to the previous menu. After all the configurations, press the SETUP button while holding down the SHIFT button. The configuration will be updated when closing SETUP MENU. Notes: •When moving the joystick to ▼at the bottom of CAM- ERA TITLE 1 of 2, the monitor will display 2 of 2 (the next page). 500 CAMERA TITLE 1 of 2 CAM TITLE 1 2 3 4 5 6 7 8 500 CAMERA TITLE 2 of 2 CAM TITLE 9 10 11 12 13 14 15 16 Notes: •If you repeat Step 1 after setting 4 motion-detection areas, “NG” will blink at the center of the monitor for two seconds. •To reset a motion-detection area, move the “+” mark on the desired area. Then, press the CLEAR button. The area will be reset. •If an area overlaps another one, the newer area will be reset. 5. To configure the motion-detector areas of another cam- era channel, press the NEXT or PREV button. 6. Repeat Step 1 to 4. Notes: •If you press the CLEAR button before determining four motion-detection areas, all the areas of the channel will be reset. •Setting point 1 and 2 are determined only when the “+” mark has moved 5 segments both vertically and hori- zontally. After the configuration, press the MON (ESC) button. The motion-detection setting will be memorized and the monitor display will return to the previous menu. After all the configurations, press the SETUP button while holding down the SHIFT button. The configuration will be updated when closing SETUP MENU.
60 •When moving the joystick to ▲at the top of CAMERA TITLE 2 of 2, the monitor will display 1 of 2 (the previous page). •Original characters are configurable through WJ- SX150 Administrator Console, but they are not dis- played correctly in SETUP MENU. They are displayed as ■. (Refer to p. 80 Edit Font window.) ■RECORDER ●How to Display To display this menu on the monitor, move the cursor to 600 RECORDER in SETUP MENU by moving the joystick to D or C. Then, press the CAM (SET) button. The submenu will appear on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. Press the numeric button(s) to enter a number. •RECORDER CONTROL This stands for the recorder type. The selectable para- meters differ depending on the existing of the Multiplexer board installation. Without the Multiplxer board HD500:Select this when a WJ-HD500 Series recorder is connected to the unit. OFF:Select this when no recorder is connected to the unit. The factory default setting is HD500. 600 RECORDER 610 REDORDER CONTROL HD500 620 RECORDER UNIT ADDRESS 1 With the Multiplexer board VCR:Select this when a time-lapse VCR is connected to the unit. HD100:Select this when a WJ-HD100 Series recorder is connected to the unit. OFF:Select this when no recorder is connected to the unit. The factory default setting is OFF. •RECORDER UNIT ADDRESS This stands for the recorder’s unit address.1 to 99 is available. ■SYSTEM SETUP ●How to Display To display this menu on the monitor, move the cursor to 600 SYSTEM in SETUP MENU by moving the joystick to ▼or ▲. Then, press the CAM (SET) button. The submenu appears on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. • COMPENSATION/VD2/DATA This menu links to the submenu. Move the cursor and press the CAM (SET) button to go into the menu. 710 COMPENSATION/VD2/DATA will appear on the moni- tor. 710 COMPENSATION/VD2/DATA CAM COMP VD2 DATA CAM COMP VD2 DATA 1 S ON ON 9 S ON ON 2 S ON ON 10 S ON ON 3 S ON ON 11 S ON ON 4 S ON ON 12 S ON ON 5 S ON ON 13 S ON ON 6 S ON ON 14 S ON ON 7 S ON ON 15 S ON ON 8 S ON ON 16 S ON ON 700 SYSTEM 710 COMPENSATION/VD2/DATA O 720 RS485 CAMERAO 730 DATA4/PSD PORT SELECT PSD 740 PSD/HDR PORT SPEED 9600bps 750 SERIAL PORT SPEED 38400bps 760 EXT IN GENLOCK OFF 770 CAMERA CLEANING OFF
61 • DATA4/PSD PORT SELECT This stands for the operation mode: PS·Data or the terminal mode. PSD:Select this when connecting a PS·Data controller to the DATA 4 port. DATA 4: Select this when connecting a terminal-mode controller to the DATA 4 port. The factory default setting is PSD. • PSD/HDR PORT SPEED This stands for the PS·Data communication speed (or baud rate) of the DATA 4 port. 19200, 9600 or 4800 bps is selectable. The factory default setting is 9600 bps. • SERIAL PORT SPEED Select the desired communication speed for SERIAL (the serial port), with the NEXT or PREV button. 38400 bps:The speed is set to 38400 bps. 19200 bps:The speed is set to 19200 bps. 9600 bps:The speed is set to 9600 bps. 4800 bps:The speed is set to 4800 bps. The factory default setting is 38400 bps. After the configuration, press the MON (ESC) button. The monitor display will return to the previous menu. After all the configurations, press the SETUP button while holding down the SHIFT button. The configuration will be updated when closing SETUP MENU. • EXT IN This stands for the setting of the EXT IN connector at the units rear panel. This menu does not appear when the Multiplexer board is installed in the unit. GENLOCK ON:Select this mode to gen-lock the unit with the recorder. OFF:Select this mode if the asynchronous unit is con- nected with the recorder. The factory default setting is GENLOCK OFF. Notes: •If GENLOCK ON is selected, the playback images or multiscreen display cannot be displayed on Monitor 1 to 4. Confirm the images on the monitor which are con- nected to the recorder. •If GENLOCK OFF is selected, the maximum rate recording becomes unavailable (when WJ-HD500A is connected to the unit).CAM:This stands for the camera number. COMP:This stands for cable compensation. Select the desired setting according to the cable length. S:Less than 400 m (1 300 ft) M:400 m (1 300 ft) to 700 m (2 300 ft) L:700 m (2 300 ft) to 900 m (3 000 ft) Refer to p. 37 for available cables. The factory default setting is S. VD2:To send the VD2 timing pulse with the camera output signal, select ON. Not to send the VD2 tim- ing pulse with the camera output signal, select OFF. The factory default setting is ON. DATA:To send the control data with the camera output signal, select ON. Not to send the control data with the camera output signal, select OFF. The factory default setting is ON. After the configuration, press the MON (ESC) button. The monitor display returns to the previous menu. • RS485 CAMERA SETUP This menu links to the submenu. Move the cursor and press the CAM (SET) button to go into the menu. 720 RS485 CAMERA will appear on the monitor. CAM:This stands for the camera number. PORT:This stands for the data port to which an RS-485 type camera is connected. The following are the parameters. • --(DISABLE): Select this when using the camera via coaxial communication or not using the cam- era. • RS485: Select this when connecting the camera to an RS-485 port. • DATA1: Select this when connecting the camera to the DATA 1 port. • DATA 2: Select this when connecting the camera to the DATA 2 port. • DATA 3: Select this when connecting the camera to the DATA 3 port. The factory default setting is DISABLE (for CAM 1 to 16). Note:The settings of camera inputs without camera con- nections are ignored. 720 RS485 CAMERA CAM PORT CAM PORT 1 -- 9 -- 2 -- 10 -- 3 -- 11 -- 4 -- 12 -- 5 -- 13 -- 6 -- 14 -- 7 -- 15 -- 8 -- 16 --
62 • CAMERA CLEANING ON:Activates the manual cleaning for the cameras. OFF:Deactivates the manual cleaning. When you set CAMERA CLEANING to ON and exit from the SETUP MENU, camera cleaning will start. The factory default setting is OFF. Notes: •When the camera cleaning is active, cleaning will begin from CAM 1 in numerical order. •Surveillance is impossible during the cleaning. •The cleaning cannot be stopped after it is started. •Refer to pp. 38 and 39 for details on RS-485 or PS·Data connections. •The camera address needs to be corresponding with the camera number. ■OPERATOR REGISTRATION ●How to Display To display this menu on the monitor, move the cursor to 800 OPERATOR REGISTRATION in SETUP MENU by mov- ing the joystick to ▼.Then, press the CAM (SET) button. The submenu appears on the monitor. ●Parameters Move the joystick to move the cursor. Press the NEXT or PREV button to select the desired para- meters. Press the numeric button(s) to enter a number. • OPERATOR NO. This stands for an operator number. When you enter the number by pressing the NEXT, PREV or numeric button(s), this menu will display the associated operators information. 1 to 16 is available. • ID This stands for an operator ID. 1 to 99999 is available. • PASSWORD This stands for an operators password. 1 to 99999 is avail- able. The password will be displayed as * on the monitor. 800 OPERATOR REGISTRATION OPERATOR NO.=01 ID =150 PASSWORD=***** PRIORITY=1 LEVEL =1 CAM01=VIEW&CONTROL CAM09=VIEW&CONTROL CAM02=VIEW&CONTROL CAM10=VIEW&CONTROL CAM03=VIEW&CONTROL CAM11=VIEW&CONTROL CAM04=VIEW&CONTROL CAM12=VIEW&CONTROL CAM05=VIEW&CONTROL CAM13=VIEW&CONTROL CAM06=VIEW&CONTROL CAM14=VIEW&CONTROL CAM07=VIEW&CONTROL CAM15=VIEW&CONTROL CAM08=VIEW&CONTROL CAM16=VIEW&CONTROL • PRIORITY This stands for an operators priority. 1 to 16 is available. (Refer to p. 14 for details on Priority Lock.) • LEVEL This stands for an operators restrict level. It is configurable through Level Table (refer to p. 76) of WJ-SX150 Administrator Console what kind of restriction is given to the operator. 1 to 3 is available. • CAM 01 to 16: These stand for an operators camera operation coverage. The following are the parameters. VIEW & CONTROL:The operator can display the camera image on the monitor and control pan- ning/tilting. VIEW ONLY:The operator can display the camera image on the monitor, but cannot control the panning/tilting. PROHIBITED:The operator can neither display the camera image on the monitor nor control the panning/tilting. The following is the factory default setting of this menu. Note:When you enter an invalid number, the parameter will return to the state before your numerical entry. ■MULTIPLEXER ●How to Display This menu will appear only when the Multiplexer board is installed in the unit. To display this menu on the moni- tor, move the cursor to 900 MULTIPLEXER in SETUP MENU by moving the joystick to Dor C. Then, press the CAM (SET) button. The submenu appears monitor. 6 OPERATOR NO. ID PASSWORD LEVEL PRIORITY 1150 150 1 1 2112345 1 2 3100 100 1 3 4101 101 1 4 5102 102 2 5 6103103 3 CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to 6 900 MULTIPLEXER VCR REC MODE 910 ALARM EXT. 920 NORMAL EXT. 930 DYNAMIC REC OFF 940 DUMMY BLACK 0FF 950 CAM SW LOSS ON