Panasonic Matrix Switcher Wj Sx150 Operating Instructions
Have a look at the manual Panasonic Matrix Switcher Wj Sx150 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
93 ■ Call Preset Position 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. To select the desired preset position number, press the numeric buttons. 4. When you have selected a wrong number, press the CLEAR button to clear the numeric input. 3. Press the CALL PRESET button to move to the preset position of the selected camera on the active monitor. ■ Program Preset Position 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. To move the camera to the position to be preset, move the joystick and press the lens control buttons. 3. To select the desired preset position number, press the numeric buttons. 4. When you have selected a wrong number, press the CLEAR button to clear the numeric input. 4. Press the CALL PRESET button while holding down the SHIFT button to save a preset position of the selected camera. SHIFT CALL PRESET PROGRAM PRESET PAUSE TOUR SEQ NEXT AUTO PAN PAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL Notes: •If the entered position number has stored the previ- ous preset position, it will be overwritten by the new one. •SETUP MENU and WJ-SX150 Administrator Console can configure each operators pan/tilt con- trol. (Refer to p. 62 OPERATOR REGISTRATION or p. 75 Operator Registration.)Note:To use the above function, you must set the pre- set position number for the camera. CALL PRESET PROGRAM PRESET AUTO PAN CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL
94 ■ Camera Function (Shortcut Function) The following function is available only when specified cam- eras with the camera function feature are used. This function enables executing camera functions via a shortcut. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button while holding down the SHIFT button. F_ _ _ _ will appear on the LED display of the con- troller as shown in the figure. ■ Camera Setup 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the F1 button while holding down the SHIFT but- ton. The CAM SETUP indicator on the controller will light up and the cameras SETUP MENU will appear on the active monitor. 3. To select the desired item in the menu, move the joy- stick to ▼or ▲. To select the desired parameter (or mode) in the menu, move the joystick to tor s. 4. To execute the currently highlighted selection and to enter a submenu of SETUP MENU, press the CAM (SET) button. 5. To leave from the currently selected menu and to return to the previous page of the menu, press the MON (ESC) button. 6. Move the cursor to SPECIAL on the camera’s setup menu, and press numeric buttons 4and 6simultane- ously for 2 seconds or more to display the special menu. 7. Move the cursor to CAMERA RESET on the camera’s setup menu, and press buttons 4, 5and 6simultane- ously to reset all the functions to the defaults. Notes: •Refer to the operating instructions of the selected camera for details. •Move the joystick while holding down the SHIFT button to move the camera smoothly for presetting the positions in the cameras SETUP MENU. 8. To close the cameras SETUP MENU, press the F1 but- ton while holding down the SHIFT button. The CAM SETUP indicator goes off. CAMERA FUNCTION CONTROL SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL 3. Press the numeric buttons to select an assigned func- tion number, then press the CAM (SET) button. For example, enter 175 for AGC ON. The selected function will be executed on the active monitor. Notes: •When you select a wrong number, press the CLEAR button to clear the numeric input. •Refer to the cameras operating instructions for details on available shortcuts. 4. To exit from the mode, press the MON (ESC) button then press the AUTO PAN button while pressing the SHIFT button. SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL
95 ■ Patrol Learn and Play A routine of manual operations can be stored for a specific time and later reproduced repetitively. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button three times while holding down the SHIFT button. LEARN will appear on the LED display of the controller as shown in the figure. ■ Changing to Black and White Images This function gets the clear camera images on the monitor while shooting the objects under low light conditions. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button two times while holding down the SHIFT button. BLACK (black) will appear on the LED display of the controller as shown in the figure. 3. Press the button 1 to change the image from the color mode to the black and white mode on the active moni- tor. BL ON (BLACK ON) appears on the LED display to indicate the selected mode. 4. Press the button 2 to change the black and white image to the color image on the active monitor. BL OF (BLACK OFF) appears on the LED display to indicate the selected mode. 5. Press the MON (ESC) button to exit from the mode. Note:When the black and white parameter is set to AUTO in the cameras SETUP MENU, this function is disabled. SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL 3. To save the patrol sequence, follow the procedure below. qPress the button 2, then press the CAM (SET) but- ton. LE R appears on the LED display. wOperate the camera manually. ePress the button 3. The operation data is saved and LE S appears on the LED display. 4. To reproduce the operation data, follow the procedure below. qPress the button 1. LE P appears on the LED display. wPress the button 3. The reproduction is ended. 5. To exit from the mode, press the MON (ESC) button.
96 ■ Camera Panning Function There are three panning modes available as follows: auto pan, sort mode and sequence mode. Refer to p. 16 Camera-related Functions for details on each mode. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the AUTO PAN button four times while holding down the SHIFT button. PAN will appear on the LED display of the controller as shown in the figure.4. To exit from the mode, press the MON (ESC) button, then press the AUTO PAN button while holding down the SHIFT button. SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL 3. Press the assigned numeric button shown below to acti- vate the panning function of the selected camera. The LED display indicates the selected mode as fol- lows. 1:Activates AUTO PAN PA PA. 2:Activates SORT PAN PA SO. 3:Activates SEQUENCE PAN PA SE. Note:The AUTO MODE parameter previously set in the cameras SETUP MENU will be automatically replaced to the activated function parameter.
97 ■ Receiver Control The following functions are available only when the receivers are included in the system and the specified camera housing is installed. ● Camera Housing Control Wiper Control 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the CAM (SET) button while holding down the SHIFT button to turn on the housing wiper of the camera until buttons are released. Defroster Control 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the button 9 while holding down the SHIFT button to turn on the housing defroster of the camera. 3. To turn off the defroster, press the button 8 while hold- ing down the SHIFT button. ● Auxiliary Control 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. Press the button 3 while holding down the SHIFT button to turn on the users auxiliary switch 1 of the receiver. Press the button 2 while holding down the SHIFT but- ton to turn off the users auxiliary switch 1 of the receiv- er. 3. Press the button 6 while holding down the SHIFT button to turn on the users auxiliary switch 2 of the receiver. Press the button 5 while holding down the SHIFT button to turn off the users auxiliary switch 2 of the receiver. SHIFT PAUSE TOUR SEQ NEXT PAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL SHIFT PAUSE TOUR SEQ NEXT PAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL SHIFT PAUSE TOUR SEQ NEXT PAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL CAMERA SITE ACCESSORIES CONTROL
98 ■ Tour Sequence The following functions are available if a tour sequence has been previously configured through SETUP MENU or WJ- SX150 Administrator Console. Any tour sequence can be assigned to any monitors. 1. Select the desired monitor and camera. (Refer to p. 90 Monitor Selection and p. 91 Camera Selection.) 2. To select the desired tour sequence number, press the numeric buttons. 3. When you have selected a wrong number, press the CLEAR button to clear the numeric input. 4. Press the TOUR SEQ button to run the tour sequence in the forward direction on the active monitor.8. Press the PREV button to move the sequence one frame to the previous step from the step that was previ- ously paused by pressing the PAUSE button. 9. Press the STOP button to stop a tour sequence on the active monitor and return to spot monitoring. ■ Group Sequence The following function is available only if a group sequence has been previously established in WJ-SX150 Administrator Console. As described earlier, a group sequence determines the assignment of monitors and cameras. Therefore, monitor selection is not required. 1. Press the numeric buttons to select a desired group sequence number. 2. When you have selected a wrong number, press the CLEAR button to clear the numeric input. 3. Press the GROUP SEQ button to run a group sequence forward on the assigned monitors. 4. Press the PAUSE, NEXT or PREV button to operate the group sequence. Refer to steps 5 to 8 of Tour Sequence in this page for how to use these buttons. 5. To stop the sequence, select one of the monitors that are being run on the selected group sequence, then press the STOP button. RUNNING SEQUENCE SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL 5. Press the PAUSE button to pause a tour sequence on the active monitor. The P sign (indicating the pause status) is displayed at the tour sequence number on the active monitor, and a camera number currently selected appears on the LED display. 6. Press the PAUSE button to restart a tour sequence for- ward from the next step that was previously paused by pressing the PAUSE button. 7. Press the NEXT button to move the sequence one frame to the next step from the step that was previously paused by pressing the PAUSE button. SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL
99 ■ On-screen Display (OSD) Control The procedure described below lets you determine the dis- play parameters, such as camera title, clock and status, on and off on the active monitor screen. Before controlling each item, monitor selection is neces- sary. (Refer to p. 90 Monitor Selection.) ●Displaying the Clock Toggle the button 1 while holding down the OSD button. (1) will appear/disappear on/from the active monitor. ●Displaying the Camera Title Toggle the button 2 while holding down the OSD button. (2) will appear/disappear on/from the active monitor. ●Displaying the Event Toggle the button 3 while holding down the OSD button. (3) will appear/disappear on/from the active monitor. ●Displaying the Monitor Status* Toggle the button 4 while holding down the OSD button. (4)* will appear/disappear on/from the active monitor. * Monitor number, controller number and monitor mode ●Displaying All the Items Toggle the button 5 while holding down the OSD button. (1), (2), (3) and (4) will appear/disappear on/from the active monitor. ■ On-screen Display (OSD) Position Control The procedure described below lets you determine the dis- play positions, such as camera title, clock and status, on the active monitor screen. ●Moving the Clock Display Move the joystick while holding down the OSD, SHIFT and 1 buttons. (1) will move to the desired direction. ●Moving the Camera Title Display Move the joystick while holding down the OSD, SHIFT and 2 buttons. (2) will move to the desired direction. MONITOR DISPLAY CONTROL 08/21/2002 12:50:28 PM M1 K1 T01 C01 camera title ALARM10*(1) (3) (4) (2) SET UP SHIFT REW/FF STEP GROUP SEQ PAUSE F2 TOUR SEQ PREVNEXT STOP OSD RECORDER INDEX STOP PLAYPAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL 08/21/2002 12:50:59 PM M1 K1 T01 C01 camera title ALARM10* Camera title Monitor statusEvent Clock SET UP SHIFT REW/FF STEP GROUP SEQ PAUSE F2 TOUR SEQ PREVNEXT STOP OSD RECORDER INDEX STOP PLAYPAUSE MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL UP LR DOWN
100 MODE:Lists the display mode on the moni- tors. SPOT:Spot mode Tnn:Tour Sequence mode (nn is the tour sequence number.) SET:WJ-SX150 Setup mode ALARM:Alarm Active mode ACK:Alarm ACK mode VLD H:VLD History Table ALM H:Alarm History Table SYS S:System Status Table KB:Lists the system controller number or PC. OPE:Lists the operator number PRI:Lists the priority number 3. To exit from the mode, press the CLEAR button.●Moving the Event Display Move the joystick while holding down the OSD, SHIFT and 3 buttons. (3) will move to the desired direction. ●Moving the Monitor Status* Move the joystick while holding down the OSD, SHIFT and 4 buttons. (4) will move to the desired direction. * Monitor number, controller number and monitor mode ●Moving All the Items Move the joystick while holding down the OSD, SHIFT and 5 buttons. (1), (2), (3), and (4) will move to the desired direction. ■ System Status Table The table shows the current system status. 1. Select the desired monitor. (Refer to p. 90 Monitor Selection.) 2. Press the button 9 while holding down the OSD button. OSD will appear on the LED display, and the SYSTEM STATUS table will appear on the active monitor as shown in the figure. The columns in the table indicate the states as shown in the figure. MON:Monitor number CAM:Camera number No number indicates no camera is selected. SYSTEM STATUS MON CAM MODE KB OPE PRI 1 01 T01 K1 1 30 2 02 SPOT K2 2 2 3 04 ALARM K4 4 1 4 16 CAM PC 30 1 SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL
101 ■ Alarm History Table There are 100 alarm records stored in chronological order in 10 pages of tables. 1. Select the desired monitor. (Refer to p. 90 Monitor Selection.) 2. Press the button 7 while holding down the OSD button. OSD will appear on the LED display, and the ALARM HISTORY table will appear on the active monitor as shown in the figure. The columns in the table indicate the states as follows: DATE:Lists the date and time when the alarm state changes. ALARM:Lists the alarm number (01 - 16). EVENT:Lists the event when the alarm state changes. 3. Press the NEXT button to select the next page of the history, and press the PREV button to back up to the previous page. 4. To exit from the mode, press the CLEAR button. ■ Video Loss History Table There are 100 video loss detection records stored in chronological order in 10 pages of table. 1. Select the desired monitor. (Refer to p. 90 Monitor Selection.) 2. Press the button 8 while holding down the OSD button. OSD will appear on the LED display, and the VIDEO LOSS HISTORY table will appear on the active monitor as shown in the figure below. The columns in the table indicate the states as follows: DATE:Lists the date and time when the video loss state changes. CH:Lists logical camera number that is connected to the system. EVENT:Lists the event when the video loss state changes. ALARM HISTORY 1 of 2 NO YYYY/MM/DD HH:MM:SS ALARM EVENT 016 2001/08/21 18:59:08 03 ALARM 015 2001/08/21 18:58:08 03 ACK 014 2001/08/21 18:57:08 03 RESET 013 2001/08/21 18:55:08 07 ALARM 012 2001/08/21 18:54:08 07 ACK 011 2001/08/21 18:53:08 07 RESET 010 2001/08/21 18:53:00 09 ALARM 009 2001/08/21 18:52:08 09 RESET 008 2001/08/21 18:51:08 06 ALARM 007 2001/08/21 18:50:08 06 ACK SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL VIDEO LOSS HISTORY 1 of 2 NO YYYY/MM/DD HH:MM:SS CH EVENT 012 2001/08/21 18:59:08 03 VIDEO RECOVER 011 2001/08/21 18:58:08 14 VIDEO RECOVER 010 2001/08/21 18:57:08 09 VIDEO LOSS 009 2001/08/21 18:55:08 07 VIDEO LOSS 008 2001/08/21 18:54:08 08 VIDEO LOSS 007 2001/08/21 18:53:08 16 VIDEO LOSS 006 2001/08/21 18:53:00 09 VIDEO LOSS 005 2001/08/21 18:52:08 14 VIDEO LOSS 004 2001/08/21 18:51:08 06 VIDEO LOSS 003 2001/08/21 18:50:08 01 VIDEO RECOVER SETUP SHIFT REW/FF STEP CALL PRESET PROGRAM PRESET GROUP SEQ PAUSE SUSPEND F1 CAM SETUPALL RESET ACKRESET F2 TOUR SEQ PREVNEXT STOP OSD AUTO PANRECORDER INDEX STOP PLAYPAUSE CAM FUNC CLEAR LOG OUTMON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL
102 ■Operating during an Alarm Mode While an alarm mode is active, the following are available from the system controller: •Operating the camera with the alarm input (ACK) •Resetting the alarm (RESET/ALL RESET) •Suspending the alarm (ALM SUSPENDED) ■Operation of an Alarm-related Camera (ACK) You can operate the camera with the alarm input as follows: 1. Select a monitor which displays ALARM. 2. Press the ACK button. ACK will appear on the monitor with an alarm input. The camera with an alarm input will become operable. 3. Operate camera with the system controller. Pan/Tilt, zoom, focus, and iris are available. When selecting another monitor, ACK will disappear from the display. The matrix switcher system will return to the alarm mode. MON LOCK DEF ON WIPER DEF OFFMON (ESC) T&D CAM ID MON STATUSALLEVENT ALM H VLD H SYS S CAM (SET) MULTI SCREEN SEL SEQUENCE AUX2 ON AUX2 OFFEL-ZOOM AUX1 ON AUX1 OFFSTILL SHIFT REW/FF STEP GROUP SEQ PAUSE SUSPEND ALL RESET ACKRESET TOUR SEQ PREVNEXT OSD PLAYPAUSE ■Alarm Mode When alarm (sensor) is accepted, the matrix switchers operation mode changes to the alarm mode. Then, the sys- tem operates as follows: •The camera image (alarm image) appears on the moni- tor. In the factory default setting, the alarm inputs 1 to 16 are associated with the same-numbered camera input connectors. All the video output signals are sent to Monitor 1. For example, when the alarm (sensor) con- nected to the alarm input 1 becomes active, the camera input connector 1’s image appears on Monitor 1. •ALARMnn appears on the monitor. The display indicates the image is input through the alarm nn (nn is the alarm number). When more than one alarm signal input has been accepted, ALARMnn * appears on the monitor. •Alarm output signals are supplied from Alarm Output 1 to 4 (#10, 11, 23 and 24) of the ALARM port (25-pin D- sub connector) at the rear panel. Alarm Output 1 to 4 is associated with MONITOR OUT 1 to 4. For example, when an alarm input signal is activated on MONITOR OUT 1, the unit supplies Alarm Output 1 to Monitor 1. •The monitor and alarm number will appear on the LED display. At the same time, the alarm indicator will blink, the monitor indicator will light up, and the camera indi- cator will go out. There are two operation mode when more than one alarm signal has been accepted by the unit that is assigned to the same monitor. • Sequence mode:An alarm operation is replaced by another one after the dwell time ends. • Hold mode:An initial alarm operation is continued even after another alarm input is accepted. Notes: •The association of the alarm inputs with cameras and monitors are changeable in SETUP MENU or WJ-SX150 Administrator Console. (Refer to p. 56 or p. 74.) •Alarm input will be automatically reset in 30 seconds. The auto-recovery time is configurable through SETUP MENU or WJ-SX150 Administrator Console. ALARM CONTROL ALARM01 ACK