    							●To Record the Camera Images in Maximum
    Recording Rate
    The following is the description of the connection between a
    recorder and this unit for the maximum-rate recording.
    1.Set the unit address of the recorder to 1. Then, set the
    recorder’s CAMERA GENLOCK to ON in its SETUP
    MENU. (Refer to the recorders operating instructions.)
    2.Connect the unit’s CAM OUT 1 to 16 connectors to the
    recorder’s VIDEO IN 1 to 16 connectors with a coaxial
    cable.
    3.Connect the unit’s EXT IN connector to the recorder’s
    GENLOCK OUT connector with a coaxial cable.
    4.Connect the unit’s DATA HDR connector to the
    recorder’s DATA port with a modular cable.
    (The control data and alarm signal will be output from
    the unit to the recorder.)
    5.After the connection, set the unit’s EXT IN to GENLOCK
    ON through SETUP MENU or WJ-SX150 Administrator
    Console (Refer to pp. 60 or 66).
    Notes:
    •You need WJ-HD500A or a newer model for the maxi-
    mum-rate recording.
    •The playback, multiscreen output or live images from the
    recorder are not displayed on Monitor 1 to 4. To confirm
    the images, you need to connect another monitor with
    the recorder. 
    •The recorder will not operate if its unit address is set to
    other than 1.
    •Make sure the DATA HDR ports unit address is set to 1
    through WJ-SX150 Administrator Console. (Refer to p.
    66.) If another number is selected, you cannot control
    the recorder.
    WJ-SX150 Matrix Switcher
    WJ-HD500A or a newer model
    16
    1615
    1514
    1413
    1312
    1211
    1110
    109
    98
    87
    76
    65
    54
    432
    2
    3
    1
    1
    SIGNAL GND10/100BASE-TSPOT
    OUTIN EXT STORAGE COPY
    CONTROL ALARM
    VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL
    INOUT
    OUTMULTI SCREEN OUTAUDIO
    EXT IN
    GENLOCK 
    OUT MULTI 
    SCREEN
    OUTDATA DATA HDR
    Monitor
    CAMERA1
    1
    2
    2
    3 3 2
    DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON4
    2
    1
    43
    EXT OUT
    (REC OUT)
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECTMONITOR OUT
    EXT IN
    (PLAY IN)
    OUT
    IN
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16 16
    RS485(CAMERA)PS•DATA
    DATA  4 DATA HDRDATA  1
    42
    Notes:
    •You cannot record the camera images in maximum
    recording rate through this connection. Refer to the next
    connection example in this page.
    •The recorder will not operate if its unit address is set to
    other than 1. 
    						
    							43
    ●To Control a Recorder via the Network
    The following is the description of the connection between
    a recorder and this unit to control the recorder via the net-
    work.
    1. Set the recorders unit address to a number 5 or larger .
    (Refer to the recorders operating instructions.)
    2. Connect the unit’s CAM OUT 1 to 16 connectors to the
    recorder’s VIDEO IN 1 to 16 connectors with a coaxial
    cable.
    3. Connect the unit’s DATA HDR and DATA4 connectors
    to the recorder’s DATA port with a daisy chain connec-
    tion cable kit (WV-CA48/10K).
    (The control data and alarm signal will be output from
    the unit to the recorder.)
    4. Select the recorders new unit address, which is set in
    step 1, for DATA HDR in the Data Port window. (Refer to
    p. 66.)
    5. Through a browser, set the unit address of an optional
    network board (WJ-HDB502) to a number other than 1.
    (Refer to WJ-HDB502 Operating Instructions.) 
    6. Refer to p. 39, p. 41 and p. 42 for MONITOR OUT con-
    nection, MULTI SCREEN OUT connection, and EXT IN
    connection.
    43
    Notes:
    •You will need WJ-HD500A or a newer model, in which
    an optional network board (WJ-HDB502) is installed.
    •Select the PS·Data protocol for the DATA 4 setting.
    (Refer to p. 61 DATA 4/PSD PORT SELECT or p. 81
    Data Port.) If the terminal mode is selected, you cannot
    control the recorder.
    •The recorder will not be operable if its unit address is
    set to 1.
    •If the recorders unit address in step 1 and the DATA
    HDR setting in step 4 are different, the recorder will not
    be operable.
    •In these connections, you cannot use a PS·Data system
    controller.
    WJ-SX150 Matrix SwitcherMonitor
     Digital Disk Recorder*
    16
    1615
    1514
    1413
    1312
    1211
    1110
    109
    98
    87
    76
    65
    54
    432
    2
    3
    1
    1
    SIGNAL GND10/100BASE-TSPOT
    OUTIN EXT STORAGE COPY
    CONTROL ALARM
    VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL
    INOUT
    OUTMULTI SCREEN OUTAUDIO
    * WJ-HD500A or Newer Models with Network Board (WJ-HDB502)
    ** LAN : Local Area Network
    CAMERA1
    1
    2
    2
    3 3 2
    DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON4
    2
    1
    43
    EXT OUT
    (REC OUT)
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECT
    MONITOR OUT
    EXT IN
    (PLAY IN)
    OUT
    IN
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16 16
    RS485(CAMERA)PS•DATA
    DATA  4 DATA HDRDATA  1
    EXT IN
    MULTI SCREEN 
    OUTDATA HDR
    DATA
    DATA4
    (PS·Data)
    MONITOR
    OUT
    Daisy Chain Connection Kit
    (WV-CA48/10K)
    HUB/Router
    LAN cable
    10/100 BASE-T
    LAN** 
    						
    							■ Connection with Digital Disk Recorder WJ-HD100 Series
    1. To record the camera images with Digital Disk Recorder WJ-HD100 Series, install an optional Multiplexer board in the
    matrix switcher.
    2. Connect the matrix switcher’s EXT OUT (REC OUT) to the digital disk recorder’s VIDEO IN with a coaxial cable.
    3. Connect the matrix switcher’s EXT IN (PLAY IN) to the digital disk recorder’s MONITOR OUT (PLAY) with a coaxial cable.
    4. Connect the matrix switcher’s DATA HDR to the digital disk recorder’s DATA with a modular cable.
    5. Connect the matrix switcher’s CAMERA SW IN to the digital disk recorder’s CAMERA SW OUT with an RCA-pin cable.
    6. Select “HD100” for 610 RECORDER CONTROL in SETUP MENU. (Refer to p. 60.)
    7. Conform the parameter of 740 PSD PORT SPEED to the setting of the recorder.
    The following parameters are fixed.
    Data bit:8 bits
    Parity check:None
    Stop bit:1 bit
    8Conform the parameter of 620 RECORDER UNIT ADDRESS in SETUP MENU to the setting of the recorder. (Refer to the
    recorder’s operating instructions for the unit address.)
    Note:After the connection, configure the system through SETUP MENU and WJ-SX150 Administrator Console.
    ●DATA HDR Port
    44
    WJ-HD100 series Digital Disk Recorder
    SIGNAL GND
    ALARM SERIES
    RECORD TIME
    ADJUST
    REMOTEMODE DATA RS-232C VIDEO OUTIN
    OUTIN
    AUDIOMONITOR OUT
    (PLAY) CAMERA
    SW  OUT
    G
    G
    G
    POWER
    ON
    OFF
    JOG-CLICK
    JOG-LEFT
    JOG-RIGHTALARM SEARCHSTEP
    REW/FF
    STOP/SETUP
    PLAY
    REC
    OUT
    PLAY OUT
    REC OUTAUTO OFF OUTDISK END OUT IN
    OUT
    IN
    RECALL (EXT REC)
    OUTRECOVER OUTRESET IN
    IN
    WJ-SX150 MatrixSwitcherPin #10 (Alarm Out 1)
    Pin #11 (Alarm Out 3)
    2DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON42 14
    3
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECT
    MONITOR OUT
    EXT IN
    (PLAY IN)
    EXT OUT
    (REC OUT)RS485(CAMERA)
    DATA  4 DATA HDR
    PS•DATADATA  1
    Pin #24 (Alarm Out 4) Pin #13 
    (Recover Input)
    Pin #23 (Alarm Out 2)
    Pin #9 (GND)
    TB
    TA
    RBRAGND
    GNDMatrix switchers rear panel
    DATA HDR
    TB
    TA
    RB
    RA
    DATA HDR Port 
    						
    							45
    ■Connection with the Time-lapse VCR (Panasonic Models)
    1. Configure the parameters of the multiplexer functions in the Multiplexer Mode (refer to p. 82) window of WJ-SX150
    Administrator Console.
    Note:When VCR is selected in 610 RECORDER CONTROL in SETUP MENU (refer to p. 60), parameter configuration in the
    Multiplexer Mode window is unavailable.
    2. Select VCR for 610 RECORDER CONTROL in SETUP MENU. (Refer to p. 60.)
    3. Conform the communication speed (COMM. SPEED) for 750 SERIAL PORT SPEED in SETUP MENU to that of the time-
    lapse VCR. (Refer to p.61.)
    The following parameters are fixed.
    Data bit:7 bits
    Parity check:ODD
    Stop bit:1 bit
    4. Connect the matrix switcher’s EXT OUT (REC OUT) to the time-lapse VCR’s VIDEO IN with the coaxial cable.
    5. Connect the matrix switcher’s EXT IN (PLAY IN) to the time-lapse VCR’s VIDEO OUT with the coaxial cable.
    6. Connect the matrix switcher’s SERIAL to that of the time-lapse VCR with a 9-pin D-sub cable.
    7. Connect the matrix switcher’s CAMERA SW IN to the time-lapse VCR’s CAMERA SW OUT with an RCA-pin cable.
    Notes:
    •Only Panasonic time-lapse VCRs which support RS-232C are usable. (Refer to Cable Specifications on the next page
    for details of cables.)
    •Both of the time-lapse VCR and PC cannot be connected to the matrix switcher.
    •When configuring the system through WJ-SX150 Administrator Console, pull out the time-lapse VCR’s cable and con-
    nect the PC’s cable to the serial port.
    •To use the alarm recording function, connect the matrix switcher’s all alarm output terminals (Alarm Output 1 to 4) to
    the time-lapse VCR’s ALARM IN.
    •Be sure to activate auto-recovery for the VCR’s alarm reset function.
    VIDEO IN
    CAMERA
    SW  OUTGND
    S-VIDEO
    AUDIOVIDEO OUT
    12
    12345678910111213141516
    1
    2
    3
    4
    ALARM
    IN
    COMALARM
    RESET IN
    ALARMRECOVER OUT
    5
    6
    7
    8
    ALARM
    OUT
    1 SHOT IN
    TAPE END
    OUT
    9
    10
    11
    12
    WARNING
    OUT
    HUMID OUT
    REC REVIEWOUT
    13
    14
    15
    16
    SERIES
    REC IN
    TIME
    ADJUST IN
    TIMEADJUST OUT
    COMREC OUT
    SERIES
    REC OUT
    Time Lapse VCR WJ-SX150 MatrixSwitcher
    2DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON42 14
    3
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECT
    MONITOR OUT
    EXT IN
    (PLAY IN)
    EXT OUT
    (REC OUT)RS485(CAMERA)
    DATA  4 DATA HDR
    PS•DATADATA  1
    Pin #23(Alarm out 2)
    Pin #9(GND)
    Pin #24(Alarm out 4)
    Pin #10(Alarm out 1)
    Pin #11(Alarm out 3)
    Pin #13 
    (Recover Input)
    4 
    						
    							46
    ■Connection with the Time-lapse VCR (Non-Panasonic Models)
    1. To record the camera images through a time-lapse VCR, install an optional Multiplexer board in the matrix switcher.
    2. Select OFF for 610 RECORDER CONTROL in SETUP MENU.
    3. Connect the matrix switcher’s EXT OUT (REC OUT) to the time-lapse VCR’s video input connector with the coaxial cable.
    4. Connect the matrix switcher’s EXT IN (PLAY IN) to the time-lapse VCR’s video output connector with the coaxial cable.
    Notes:
    •To use the alarm recording function, connect the matrix switcher’s all alarm output terminals (Alarm Output 1 to 4) to the
    time-lapse VCR’s ALARM IN.
    •Refer to p. 45 “Connection with the Time-lapse VCR (Panasonic Models) ” for the illustration.
    •Be sure to set the VCR to automatically recover from alarm reset.
    VIDEO IN
    CAMERA
    SW  OUTGND
    S-VIDEO
    AUDIOVIDEO OUT
    12
    12345678910111213141516
    1
    2
    3
    4
    ALARM
    IN
    COMALARM
    RESET IN
    ALARMRECOVER OUT
    5
    6
    7
    8
    ALARM
    OUT
    1 SHOT IN
    TAPE END
    OUT
    9
    10
    11
    12
    WARNING
    OUT
    HUMID OUT
    REC REVIEWOUT
    13
    14
    15
    16
    SERIES
    REC IN
    TIME
    ADJUST IN
    TIMEADJUST OUT
    COMREC OUT
    SERIES
    REC OUT
    Time Lapse VCR WJ-SX150 MatrixSwitcher
    2DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON42 14
    3
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECT
    MONITOR OUT
    EXT IN
    (PLAY IN)
    EXT OUT
    (REC OUT)RS485(CAMERA)
    DATA  4 DATA HDR
    PS•DATADATA  1
    Pin #23(Alarm out 2)
    Pin #9(GND)
    Pin #24(Alarm out 4)
    Pin #10(Alarm out 1)
    Pin #11(Alarm out 3)
    Pin #13 
    (Recover Input)
    4
    ■Cable Specifications
    1
    2
    3
    4
    5
    6
    7
    8
    9
    Frame1
    2
    3
    4
    5
    6
    7
    8
    20
    22
    Frame
    Shield
    WJ-SX150 T/L VCR
    AG6730, AG6740
    1
    2
    3
    4
    5
    6
    7
    8
    91
    2
    3
    4
    5
    6
    7
    8
    9
    Straight Cable
    RT850 WJ-SX150
    RT850 
    						
    							47
    ■Connection with the PC
    1. Conform the communication speed (SERIAL PORT
    SPEED) parameter in SETUP MENU to that of the PC.
    2. Connect the matrix switchers serial port to that of the
    PC with the 9-pin D-sub cable.
    Notes:
    •The following parameters are fixed.
    Data bit:8 bits
    Parity check:none
    Stop bit:1 bit 
    •Refer to Cable Specifications in this page for details on
    cables. 
    ●Cable Specifications
    1
    2
    3
    4
    5
    6
    7
    8
    Frame1
    2
    3
    4
    5
    6
    7
    8
    Frame
    Shield
    PC WJ-SX150
    SERIAL
    Personal Computer Matrix Switcher
    D-sub9 D-sub9
    or
    D-sub25
    ■Time Adjustment with an External
    Equipment
    The specified external devices can output the time adjust-
    ing signal to the matrix switcher.
    This signal can adjust the time by up to ± 30 seconds every
    hour. 
    To use this function, it is necessary to assign one of the
    alarm input terminals (pin # 1 to 16) to the time adjusting
    terminal.
    SETUP MENU or WJ-SX150 Administrator Console can
    assign the signal.
    ●Master Clock Connection Example for Time
    Adjustment
    Connect the matrix switchers time adjusting terminal to
    those of the master clock with the twisted pair cable.
    The figure below shows the case in which Alarm Input 16 is
    assigned as the time adjusting terminal.
    Note: A master clock with N.O. (Normally Open alarm con-
    tact)-type output is connectable.
    12
    63 9
    Master clockMatrix Switcher
    ALARM
    Pin #21
    Pin #22
    GND 
    						
    							49
    WJ-SX150 SETUP PROCEDURES 
    						
    							50
    SETUP PROCEDURES
    ■Setup Procedures
    This unit has two setting procedures.
    The one is SETUP MENU, which is the units on-screen dis-
    play (OSD).
    The other is WJ-SX150 Administrator Console, which oper-
    ates on the PC.
    •SETUP MENU (OSD)
    The basic functions, which are essential for the operation,
    are configurable. However, some items are not config-
    urable. The settings about group sequences, operators and
    schedules, etc.
    •WJ-SX150 Administrator Console (PC)
    All the functions of this unit are configurable. You need a
    PC to use WJ-SX150 Administrator Console.
    Refer to p. 64 WJ-SX150 ADMINISTRATOR CONSOLE for
    details of the platform and installation.Notes:
    •To use WJ-SX150 Administrator Console, you need to
    prepare a PC and a 9-pin D-sub cable.(Refer to p. 47.)
    •When changing the configuration of WJ-SX150
    Administrator Console, configuration data getting and
    putting are necessary between the unit and PC to acti-
    vate your configuration.
    ■Description of Setup Procedures
    This chapter describes about configurable items.
    ●Sequence Settings
    SETUP MENU can configure tour sequences. WJ-SX150
    Administrator Console can configure both of tour
    sequences and group sequences.
    •Tour sequence: Up to 16 tour sequences are config-
    urable (16 steps per tour). 
    •Group sequence: Tour sequences can be activated on
    up to 4 monitors simultaneously (1 tour sequence per
    monitor).
    ●Schedule Settings
    SETUP MENU can configure daylight saving time. WJ-
    SX150 Administrator Console can configure timer event,
    camera cleaning, and daylight saving time.
    •Timer event: A sequence or spot mode can be activat-
    ed on the regular time of every month, week or day.
    Up to 30 timer events can be registered.
    •Camera cleaning: Camera cleaning can be executed
    on the regular time of every month, week or day.
    •Daylight saving time: Daylight saving times for 20 years
    are configurable.
    ●Alarm Settings
    The operation parameters when an alarm is input to the unit
    are configurable.
    •Alarm mode: The  operation mode activated along with
    an alarm input is configurable. Sequence mode or hold
    mode is selectable. Alarm mode can be set to OFF
    when not using it.
    •Alarm event: The event activated along with an alarm
    input is assignable to each alarm input terminals. The
    sequence number or spot camera is selectable for the
    alarm event.
    •Alarm input (Alarm port): The alarm polarity (N. O. or N.
    C.) is assignable to each alarm input terminal. One of
    16 terminals is assignable for time adjustment.
    SETUP MENU (OSD)
    WJ-SX150 Administrator Console (PC)
    Sequence settings
     • Tour sequence
     • Group sequence
    Schedule settings
     • Timer event 
     • Camera cleaning 
     • Daylight saving time
    Alarm settings
     • Alarm mode 
     • Alarm event 
     • Alarm input/Alarm port
    Operator settings
     • Operator registration
     • Level table 
     • Monitor select (Monitor selection) 
     •
    Auto login/logout (Auto log-in/log-out)
    System settings
     • Clock (Time and date) *1 
     • Cable compensation 
     • Camera title
     • Data port *
    2
    Multiplxer board 
     • Recorder
     • Multiplexer *
    3
     • Mux (Multiplxer camera title) *3
     
    Setup file operation
     • Put a file to SX150
     •
    Get a configuration data from the SX150
    SX150 Admin Console Configuration 
     • File Open
     • Account Manager
     • Communication (Serial) port 
     • Camera manual cleaning ON/OFF
    *
    1 WJ-SX150 Administrator Console can configure the 
    display pattern.
    *
    2 WJ-SX150 Administrator Console can configure the 
    communication speed (baud rate) of the ports Data 1 to 4.
    *
    3 These menus (or windows) appear only when the Multiplxer 
    is installed in the unit. 
    						
    							51
    •It is also selectable whether to activate the recording
    and sequence/spot image monitoring when an alarm
    signal is input to the unit. Alarm recording without the
    sequence/spot image monitoring is also available.
    ●Operator Settings
    If you control this unit with a terminal-mode system con-
    troller, your operator information, controllable monitors and
    auto log-in/log-out will be registrable and configurable.
    •Operator registration: Up to 16 operators are available.
    ID and password for operator identification are config-
    urable. Level and priority can be assigned to each
    operator. Each cameras control coverage is also con-
    figurable.
    •Level table: Restriction level for each password is cus-
    tomizable.
    •Monitor select (Monitor selection): Controllable monitor
    can be assigned to each controller.
    •Auto login/logout (Auto log-in/log-out): Auto log-in/log-
    out is configurable for each controller.
    Notes:
    •These settings (except Operator registration) are con-
    figurable only through WJ-SX150 Administrator
    Console. Operator registration is configurable through
    SETUP MENU and WJ-SX150 Administrator Console.
    •When you control the unit with a PS·Data system con-
    troller, the above settings will be invalid. Refer to the
    system controllers operating instructions.
    ●System Settings
    SETUP MENU can configure the clock (time and date),
    cable compensation and camera title.
    Besides these settings, WJ-SX150 Administrator Console
    can select the data ports baud rates.
    •Clock (Time and date): The units time and date are
    configurable.
    •Cable compensation: Cable compensation type is
    selectable depending on the distance between a cam-
    era and the unit. It is also possible to determine whether
    to send the VD2 timing pulse or control data with the
    camera output signals.
    •Camera title: Camera title is configurable to identify the
    camera images on the monitor. WJ-SX150 Administrator
    Console can configure the camera title including origi-
    nal characters.
    •Data port: Usually, the ports DATA 1 to 3 connect to the
    terminal-mode system controllers. RS-485 cameras will
    be connectable with the data port configurations
    through WJ-SX150 Administrator Console and SETUP
    MENU.
    When you use the system controllers via the PS·Data
    protocol, you need to configure the DATA 4 port setting
    through SX150 Admin Console or SETUP MENU.
    •EXT IN: External synchronization of the EXT IN connec-
    tor is set to ON or OFF.
    ●Multiplexer
    •Recorder: The type and unit address of the recorder
    are configurable.
    •MULTIPLEXER: The parameters of the recorder mode
    are configurable. You can set the alarm and normal
    recording rate. You can also activate/deactivate
    dynamic recording, dummy black, and CAM SW LOSS”
    indication.
    •MUX (Multiplxer) CAMERA TITLE: Camera titles which
    are displayed with Multiscreen segments are config-
    urable.
    ●Setup File Operation
    WJ-SX150 Administrator Console can send a configuration
    file from the PC to this unit. The utility can also send the file
    from the unit to the PC for configuration. 
    •Put to a file: A configuration data is sent from the PC to
    the unit.
    •Get from a file: A configuration data is sent from the unit
    to the PC.
    •Select setup data file: A configuration data is selected
    when sending it from the PC to the unit (or from the unit
    to the PC.)
    Note:These settings are configurable only through WJ-
    SX150 Administrator Console.
    ●WJ-SX150 Administrator Console
    Configuration 
    The PC-related settings are configurable.
    •Account Manager: WJ-SX150 Administrator Console
    operators are registrable and changeable.
    •Communication (Serial) port: PCs usable communica-
    tion port number and its baud rate (communication
    speed) are configurable. 
    						
    							52
    WJ-SX150 SETUP MENU (OSD)
    The WJ-SX150 SETUP MENU (SETUP MENU) enables func-
    tion controls that are not available by direct operation.
    Note: Only one operator can enter SETUP MENU.
    ■Displaying SETUP MENU
    To display SETUP MENU, follow the procedure below.
    1. Confirm that the camera and peripherals are correctly
    and securely connected and that all components are
    turned on.
    2. To execute the selection, select one of the monitors (1
    to 4) by pressing the numeric button, then press the
    MON (ESC) button. 
    The MONITOR indicator will light up.
    3. Press the SETUP button while holding down the SHIFT
    button on the system controller.
    WJ-SX150 SETUP MENU will appear on the active mon-
    itor as shown below, and the system controllers SETUP
    indicator will light up.
    The tree of SETUP MENU is shown in the next page.
    Note:“x.xx” in SETUP MENU shows the firmware ver-
    sion.
    The following functions and buttons are valid in SETUP
    MENU:
    Joystick to UP(D):Moves the cursor up or returns to
    the previous page.
    Joystick to DOWN(C):Moves the cursor down or dis-
    plays the next page.Joystick to L(A):Moves the cursor to the left.
    Joystick to R (B):Moves the cursor to the right.
    PREV button:Selects the previous mode or parameter.
    NEXT button:Selects the next mode or parameter.
    Numeric buttons:Enters numerals.
    CLEAR button:Deletes a character when editing a
    camera title.
    CAM (SET) button:Executes the selections and dis-
    plays a submenu for items with the (O) mark.
    MON (ESC) button:Returns to SETUP MENU or the
    previous menu.
    This operating instructions uses the symbols to
    describe the buttons.
    4. To end the setting and return to the normal view, press
    the SETUP button while holding down the SHIFT button
    when SETUP MENU is displayed.
    The system controllers SETUP indicator will go off.
    Note:The Multiplexer board version, “900 MULTIPLEX-
    ER”, and “1000 MUX CAMERA TITLE” is displayed
    only when the Multiplexer board is installed in the
    unit.
    ■ Programming SETUP MENU
    As shown in the tree, SETUP MENU has seven main sub-
    menus:
    TIME & DATE, D. S. T., SEQUENCE SETUP, ALARM
    SETUP, CAMERA TITLE, SYSTEM SETUP and OPERATOR
    REGISTRATION.
    SEQUENCE SETUP, ALARM SETUP, CAMERA TITLE, SYS-
    TEM SETUP and OPERATOR REGISTRATION are further
    divided into additional submenus.
    The (O) mark indicates that the item has a submenu for
    more detailed setups.
    Refer to the figure in next page for the composition of
    SETUP MENU.
    ■TIME & DATE
    SETUPSHIFT WJ-SX150 SETUP MENU            x.xx/x.xx
      100 TIME&DATE     Aug/21/2002 10:55 AM
      200 D.S.T.        ON           
      300 SEQUENCE
    O  400 ALARMO  500 CAMERA TITLEO  600 RECORDERO  700 SYSTEMO  800 OPERATOR REGISTRATIONO 
      900 MULTIPLEXERO 1000 MUX CAMERA TITLEO
    (Without the Multiplexer board)*
    (With the Multiplexer board)
    * This is the factory default setting.
     WJ-SX150 SETUP MENU                 x.xx
     100 TIME&DATE      Aug/21/2002 10:55 AM
     200 D.S.T.         ON           
     300 SEQUENCE
    O 400 ALARMO 500 CAMERA TITLEO 600 RECORDERO 700 SYSTEMO 800 OPERATOR REGISTRATIONO
     WJ-SX150 SETUP MENU            x.xx/x.xx
      100 TIME&DATE     Aug/21/2002 10:55 AM
      200 D.S.T.        ON           
      300 SEQUENCE
    O  400 ALARMO  500 CAMERA TITLEO  600 RECORDERO  700 SYSTEMO  800 OPERATOR REGISTRATIONO
      900 MULTIPLEXERO 1000 MUX CAMERA TITLEO 
    						
    All Panasonic manuals Comments (0)