    							32
    DC 9V INDATA MODE
    RISK OF ELECTRIC SHOCK. DO  NOT OPENRISQUE DE CHOCS ELECTROUES
    NE PAS OUVRIR
    0987654321
    (1(2(0
    CONTROLLER No.
    *9
    *8
    *8Controller Number switch (CONTROLLER No.)
    Selects a number for the system controller for identifica-
    tion in a system. Normally, set the switch to number 1.
    *9Mode Selection switches (MODE)
    The operation mode of the system controller is selected
    with these switches.
    When you use a terminal-mode system controller, set
    the switches to the positions shown in the figure.
    Note:When you use a PS·Data system controller, refer
    to the system controllers operating instructions.
    ● Rear View
    DC 9V IN(3
    0987654321
    CONTROLLER No.
    #1
    MODE
    123456 78
    OFF
    ON
    4 (0
    Data ports (DATA)
    Exchange the control data with the matrix switcher via
    RS-485 cable (supplied with the system controller).
    (1DC 9V Input jack (DC 9V IN)
    Use this jack to plug the AC adapter supplied with the
    system controller.
    (2Clamp
    Fastens the supplied AC adapters power cord.
    (3AC adapter
    Caution:Use only the supplied AC adapter to feed 9 V
    DC to the system controller.
    Note:Disconnect the plug from the controller before
    setting the controller number switch or mode selec-
    tion switch, and reconnect it when finished. The
    new settings will take effect when the power is
    turned on. 
    						
    							33
    INSTALLATIONS AND SYSTEM
    CONNECTIONS 
    						
    							34
    Notes:
    •An optional cooling fan attached inside the unit is
    subject to wear. It needs to be replaced periodical-
    ly.
    Keep the temperature in the rack below 45 °C
    (113 °F) at any time. 
    •If the rack is subject to vibration, secure the rear of
    the appliance to the rack by using additional mount-
    ing brackets (procured locally).
    ■Installing the Multiplexer Board
    To use WJ-HD100 Series or a time-lapse VCR as a
    recorder, you need to install a multiplexer board inside the
    matrix switcher. Refer to the multiplexer board’s operating
    instructions for how to install.
    INSTALLATIONS
    WARNING
    The installations described in the figures should be
    made by qualified service personnel or system
    installers.
    ■ Mounting into the Rack
    The matrix switcher can be mounted into the rack as
    described.
    1. Remove the four rubber feet by unwinding the four
    screws on the bottom of the matrix switcher.
    2. Place the rack mounting brackets on both sides of the
    matrix switcher and tighten with the four supplied
    screws (M4 X10).
    3. Install the matrix switcher in the rack with the rack
    mounting brackets secured with four screws (procured
    locally).
    Remove 4 rubber feet 
    						
    							35
    SYSTEM CONNECTION EXAMPLES
    ■Basic System Connection
    This is an example of basic system connection. 
    Camera
    16 Camera
    1Camera
    2Camera
    3
    CAMERA IN 1 to 16
    ALARM IN 1 to 16 
    Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 WJ-SX150
    Matrix Switcher
    Matrix Switcher WJ-SX
    OPERATE
    NEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System Controller
    OPERATE LED WILL BLINK
    IF COOLING FAN MALFUNCTIONS
    Note:Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP
    MENU or WJ-SX150 Administrator Console.
    ■System Expansion Connection
    ●Connection with Digital Disk Recorder WJ-HD500 Series
    When connecting the camera output connectors to Digital Disk Recorder WJ-HD500 Series, the digital disk recorder can
    record all the camera channels. More than one camera images can be displayed in multiscreen segments on the desired mon-
    itor.
    REMOTO
    TIMER
    OPERATE
    FULL
    HDD
    SEQUENCESET LOCK
    ALARM
    ALARM
    RESET
    ALARM
    SUSPENDMULTISCREEN
    SELECT
    SET UP
    /ESCGROUP
    SELECT
    SPOTMULTISCREEN
    DAYLIGHT SAVINGS
    EL-ZOOM
    COPYREC PREVIEWINDEXSTOP PLAY/    PAUSE REC
    FWD REV
    ALARM SEARCH
    DISPLAYREC STOP1234
    1314151691011125678
    Digital Disk
    Recorder
    WJ-HD             A 
    FS16 16
    Camera
    16 Camera
    1Camera
    2Camera
    3
    CAMERA IN 1 to 16
    ALARM IN 1 to 16
    Matrix Switcher WJ-SX
    OPERATE
    Digital Disk Recorder WJ-HD500 SeriesMax. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4
    Available for live or play-backed camera images
    (GENLOCK OFF)
    NEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System Controller
    OPERATE LED WILL BLINK
    IF COOLING FAN MALFUNCTIONS
    WJ-SX150 Matrix Switcher 
    						
    							36
    Notes:
    •Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or
    WJ-SX150 Administrator Console.
    •If an optional network board is installed inside the recorder and you are to control it from LAN (local area network) or the
    Internet, refer to a service manual procurable in your area.
    ●Connection with Digital Disk Recorder WJ-HD100 Series or Time-lapse VCR
    •With the multiplexer board, the recorded images of Camera 1 to 16  can be multiplexed to Digital Disk Recorder, WJ-
    HD100 Series or a time-lapse VCR.
    Digital Disk Recorder WJ-HD100A or Time-Lapse VCR
    Camera
    16 Camera
    1Camera
    2Camera
    3
    Max. 16
    Camera Inputs
    16 Alarm Inputs
    Multiplexer Board
    WJ-SXB151
    Max. 4 System Controllers 4 Monitor Outputs
    Available for surveillance or playback of the camera images WJ-SX150 Matrix Switcher
    Matrix Switcher WJ-SX
    OPERATE
    NEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System Controller
    OPERATE LED WILL BLINK
    IF COOLING FAN MALFUNCTIONS
    To use WJ-HD100 Series or a time-lapse VCR as a recorder, you need to install a multiplexer board inside the matrix
    switcher. 
    						
    							37
    Connect non-multiplex type cameras to the CAMERA IN
    connectors 1 to 16. For cameras equipped with RS-485
    communication facilities, connect the RS-485 cable as fol-
    lows.
    Check the camera addresses when using RS-485 cameras.
    Operations from the system controller will be invalid if the
    camera addresses are set improperly.
    •Use addresses from 1 to 16 for individual cameras.
    •Do not set the same address for more than one camera
    in an RS-485 chain.
    •Before connecting the RS-485 camera(s) to DATA 1, 2
    and/or 3, configure the system through WJ-SX150
    Administrator Console.■ Connection with the Camera Sites
    Connect the data-multiplex type cameras (or camera site
    equipment) to the CAMERA IN connectors 1 to 16 on the
    matrix switchers rear panel.
    Notes:
    •Make sure that the cable length is less than 900 m
    (3 000 ft) between the camera site and the unit when
    using RG-59/U, BELDEN 9259 or equivalent cables. 
    •If you use locally procuring cables, it is important to use
    only a data-grade cable, which is suitable for RS-485
    communication (shielded 2-wire twisted cable). 
    •When the cable length is extended, cable compensa-
    tion is available. (Refer to pp. 60 and 78.) 
    AUXAlarm
    WJ-SX150 Matrix Switcher 
    CAMERA1 12
    23
    3
    DATA  3 D ATA  2
    OUTIN
    4 45
    56
    67
    78
    89
    910
    1016
    16
    RS485(CAMERA)
    DATA  1
    24
    RS485(CAMERA)LINE
    SELECT
    CONNECTIONS 
    						
    							38
    ■ Connections for RS-485 Type Camera
    There are two options to connect the camera with the matrix
    switcher, depending on the distance between them. 
    One is Home Run wiring and the other is daisy chain
    wiring. Home Run wiring has the transmission stability with
    less transmission loss, and daisy chain wiring has connec-
    tion flexibility with less data ports occupied. For data-multi-
    plex type cameras, 900 meters (3 000 ft) is the limit to use
    coaxial cable such as RG-59/U, BELDEN 9259 or equiva-
    lent.
    Note: If more distance is required, use cameras and
    matrix switcher with RS-485 communication feature.
    Remote control becomes possible.
    ●Home Run Wiring
    1. Connect with a RS-485 camera in Home Run wiring as
    shown in the figure.
    2. Set the LINE SELECT switch to 2 or 4.
    Notes:
    •Before connecting RS-485 cameras to DATA1 to 3, data
    port setting through WJ-SX150 Administrator Console is
    necessary. (Refer to p. 81 Data Port.)
    •Recommended for RS-485 communication is AWG#22
    or thicker one. The cable should be shielded, two-wire,
    twisted pair, and with low impedance.
    •Set the LINE SELECT switch to 4 when programming
    preset position of WV-CSR600/650 Series camera is
    connected to the unit.●Daisy Chain Wiring
    1. Draw up a plan for connection between the cameras
    and the input channels of the matrix switcher, and the
    assignment of unit addresses to cameras.
    2. Set the LINE SELECT switch to 2. Also, set the connect-
    ed devices switch if required.
    3. Connect one end of the cable to RS-485 (CAMERA),
    and the other end to the first camera in the chain, as
    shown in the figure. Repeat this procedure for all cam-
    eras. 
    4. Set the termination switches of the cameras at the chain
    ends to ON. Cameras termination switches must be set
    to OFF except the ones at the chain ends.
    Notes:
    •Set the same number for the cameras unit address as
    and CAMERA IN.
    •Check the settings of the camera addresses when
    using RS-485 cameras. Operations from the system
    controller will be invalid if the camera addresses are set
    improperly.
    •Do not use addresses other than 1 to 16 for individual
    cameras (More than 17 cameras are not allowed).
    •Do not set the same address for more than one camera
    in an RS-485 chain.
    •Termination is the key to data transmission and recep-
    tion in the chain. While the other switches are set to
    OFF, only the switches at the chain ends must be set to
    ON.
    •The termination of this units RS-485 camera port is
    always set to ON. Connect the unit at the end of the
    daisy chain.
    •The more equipment there is in the chain, the slower
    the response may be.
    WJ-SX150
    RS-485 type camera
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA)
    DATA  4
    PS•DATA DATA HDRDATA  1
    Set it to 
    position 4.
    WV-CPR450 and others  (For the 
    Termination Switch positions, refer 
    to the oprating instractions of the 
    camera.)
    (A)(B)GND
    OFF ON
    WJ-SX150
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA)
    DATA  4DATA  1
    Set it to 
    position 2.
    DATA HDR
    PS•DATA
    RB
    RA
    TBTAGND
    NoneMatrix switchers rear panel
    TB
    TA
    RB
    RA
    RS485 Port 
    						
    							39
    ■ Connection with the Monitors
    Connect the monitors to the MONITOR OUT connectors at
    the units rear panel with the coaxial cable.
    The connectors MONITOR OUT 1 to 4 are associated to
    Monitor 1 to 4. When you control the monitors from a PS·
    Data controller, the connectors MONITOR OUT are associ-
    ated to Unit 1 to 4.
    Martix Switcher
    Monitor 1 Monitor 2 Monitor 4 Monitor 3
    2 14
    3MONITOR OUT
    (A)(B)GND
    OFF ON(A)(B)GND
    OFF ON
    WV-CPR450 and others
    Set it to 2 or 4
    (the same as
    the connected
    equipment).
    The switch on a daisy-
    chain-connected unit 
    other than the 
    extremities must be set 
    to OFF.The switch on the end 
    unit should be set to 
    ON.
    (For the termination 
    switch positions, refer 
    to the operating 
    instruction of the 
    corresponding unit.)
    WJ-SX150
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA) PS•DATA
    DATA  4DATA  1DATA HDR
    Auto termination works inside the matrix switcher.  
    WJ-SX150 Matrix Switcher 
    CAMERA1 12
    23
    3
    DATA  3 D ATA  2
    OUTIN4 45
    56
    67
    78
    89
    910
    1016
    16
    RS485(CAMERA)
    DATA  1
    Unit address 1 Unit address 2 Unit address 3 Unit address 4
    Set the same 
    number for the 
    cameras unit 
    address as and 
    CAMERA IN. 
    						
    							■ Connection with the Alarm Sensors
    Connect the sensor switches to the units alarm port, as
    shown in the example.
    Notes:
    •Alarm inputs that are simultaneous or with very short
    intervals will be ignored.
    Allow for at least 100 ms interval from one alarm input to
    the next.
    •Confirm the alarm sensor type (N.O. or N.C.) and con-
    figure the system through SETUP MENU (OSD) or WJ-
    SX150 Administrator Console.
    The factory setting is N.O.
    N.O.:Normally Open alarm contact
    N.C.:Normally Closed alarm contact
    •The alarm pin assigned to the time adjust (TIME) termi-
    nal cannot be used as an alarm input terminal.
    25 13141
    Alarm
    Sensor 1
    Alarm
    Sensor 2
    ALARMRecover
    Input
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13Alarm Input 1
    Alarm Input 3
    Alarm Input 5
    Alarm Input 7
    Alarm Input 9
    Alarm Input 11
    Alarm Input 13
    Alarm Input 15
    GND
    Alarm Output 1
    Alarm Output 3
    GND
    Recover Input Pin No. Designation
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25Alarm Input 2
    Alarm Input 4
    Alarm Input 6
    Alarm Input 8
    Alarm Input 10
    Alarm Input 12
    Alarm Input 14
    Alarm Input 16
    GND
    Alarm Output 2
    Alarm Output 4
    GND Pin No. Designation
    40
    ■ Connection with the System
    Controllers
    Connect the system controller to the DATA 1 to 4 port at the
    units rear panel with the modular cable.
    Notes:
    •Up to four system controllers are connectable.
    •Connect them in home run.
    •In the factory default setting, the DATA 4 port is a
    PS·Data terminal. To connect a terminal-mode system
    controller to this port, you need to change the data port
    setting through SETUP MENU or WJ-SX150
    Administrator Console. (Refer to pp. 60 or 81.)
    WJ-SX150
    System controller System controller
    2
    DATA  3 D ATA  2
    TERM
    OFF ON
    4
    RS485(CAMERA)LINE
    SELECT
    RS485(CAMERA) PS•DATA
    DATA  4 DATA HDRDATA  1
    NEXT
    For Matrix Switcher (WJ-SX150)WV-CU C360System Controller
    NEXT
    For Matrix Switcher (WJ-SX150)WV-CU C360System Controller
    RB
    RA
    TBTAGND
    GNDMatrix switchers rear panel
    DATA 1 to 4 
    TB
    TA
    RB
    RA
    DATA1 to DATA4 Port 
    						
    							41
    ■Connection with Digital Disk
    Recorder WJ-HD500 Series
    Note: Refer to a service manual procurable in your area, for
    details on the connection with a recorder (after the net-
    work board installation) to operate via LAN or the
    Internet.
    ●To Confirm the Images from a Recorder
    Connected to the Unit
    The following is the description of the connection between a
    recorder and this unit to confirm the images from the
    recorder.
    1. Set the unit address of the recorder to 1. Then, confirm
    that the recorder’s CAMERA GENLOCK is set to OFF in
    its SETUP MENU. (Refer to the recorders operating
    instructions.)
    2. Connect the unit’s CAM OUT 1 to 16 connectors to the
    recorder’s VIDEO IN 1 to 16 connectors with a coaxial
    cable.
    3. Connect the unit’s EXT IN connector to the recorder’s
    MULTI SCREEN OUT connector with a coaxial cable.
    4. Connect the unit’s DATA HDR connector to the
    recorder’s DATA port with a modular cable.
    (The control data and alarm signal will be output from
    the unit to the recorder.)
    5. After the connection, set the unit’s EXT IN to GENLOCK
    ON through SETUP MENU or WJ-SX150 Administrator
    Console (Refer to pp. 60 or 66).
    WJ-SX150 Matrix SwitcherMonitor
    WJ-HD500 Series Digital Disk Recorder
    16
    1615
    1514
    1413
    1312
    1211
    1110
    109
    98
    87
    76
    65
    54
    432
    2
    3
    1
    1
    SIGNAL GND10/100BASE-TSPOT
    OUTIN EXT STORAGE COPY
    CONTROL ALARM
    VIDEOMODEDATAREMOTE(WV-CU50)GEN-LOCK OUTSERIAL
    INOUT
    OUTMULTI SCREEN OUTAUDIO
    CAMERA1
    1
    2
    2
    3 3 2
    DATA  3 D ATA  2SERIAL ALARM
    TERM
    OFF ON4
    2
    1
    43
    EXT OUT
    (REC OUT)
    CAMERA
    SW  INRS485(CAMERA)LINE
    SELECTMONITOR OUT
    EXT IN
    (PLAY IN)
    OUT
    IN
    4
    4
    5
    5
    6
    6
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    15
    15
    16 16
    RS485(CAMERA)PS•DATA
    DATA  4 DATA HDRDATA  1
    EXT IN
    MULTI SCREEN 
    OUTDATA HDRMONITOR
    OUT
    ■Connection with the Alarm Output
    Pins #10, 11, 23 and 24 (open collector) turns to 0 V while
    the alarm is activated. These terminals can drive external
    warning devices such as a buzzer or lamp of up to 100 mA,
    16 V DC. If the rating exceeds 100 mA, 16 V DC use a relay
    as shown in Example 2.
    Alarm signals are output from the terminals until the reset.
    Example 1:Direct drive connection
    Example 2:Connection of devices exceeding drive
    NO
    C NC
    To  Buzzer
    Relay
    +12V
    GND
    NC: Normally Closed Contact
    NO: Normally Open Contact
    C: Common
    Buzzer 
    						