Page 31
32 DC 9V INDATA MODE RISK OF ELECTRIC SHOCK. DO NOT OPENRISQUE DE CHOCS ELECTROUES NE PAS OUVRIR 0987654321 (1(2(0 CONTROLLER No. *9 *8 *8Controller Number switch (CONTROLLER No.) Selects a number for the system controller for identifica- tion in a system. Normally, set the switch to number 1. *9Mode Selection switches (MODE) The operation mode of the system controller is selected with these switches. When you use a terminal-mode system controller, set the switches to the positions shown in the figure....
Page 33
34 Notes: •An optional cooling fan attached inside the unit is subject to wear. It needs to be replaced periodical- ly. Keep the temperature in the rack below 45 °C (113 °F) at any time. •If the rack is subject to vibration, secure the rear of the appliance to the rack by using additional mount- ing brackets (procured locally). ■Installing the Multiplexer Board To use WJ-HD100 Series or a time-lapse VCR as a recorder, you need to install a multiplexer board inside the matrix switcher. Refer to the...
Page 34
35 SYSTEM CONNECTION EXAMPLES ■Basic System Connection This is an example of basic system connection. Camera 16 Camera 1Camera 2Camera 3 CAMERA IN 1 to 16 ALARM IN 1 to 16 Max. 4 System Controllers Terminal-mode PS·Data/Terminal-modeMONITOR OUT 1 to 4 WJ-SX150 Matrix Switcher Matrix Switcher WJ-SX OPERATE NEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix Switcher (WJ-SX150)WV-CU C360System ControllerNEXTFor Matrix...
Page 35
36 Notes: •Before connecting a terminal-mode system controller to the DATA 4 port, configure the system through SETUP MENU or WJ-SX150 Administrator Console. •If an optional network board is installed inside the recorder and you are to control it from LAN (local area network) or the Internet, refer to a service manual procurable in your area. ●Connection with Digital Disk Recorder WJ-HD100 Series or Time-lapse VCR •With the multiplexer board, the recorded images of Camera 1 to 16 can be multiplexed to...
Page 36
37 Connect non-multiplex type cameras to the CAMERA IN connectors 1 to 16. For cameras equipped with RS-485 communication facilities, connect the RS-485 cable as fol- lows. Check the camera addresses when using RS-485 cameras. Operations from the system controller will be invalid if the camera addresses are set improperly. •Use addresses from 1 to 16 for individual cameras. •Do not set the same address for more than one camera in an RS-485 chain. •Before connecting the RS-485 camera(s) to DATA 1, 2...
Page 37
38 ■ Connections for RS-485 Type Camera There are two options to connect the camera with the matrix switcher, depending on the distance between them. One is Home Run wiring and the other is daisy chain wiring. Home Run wiring has the transmission stability with less transmission loss, and daisy chain wiring has connec- tion flexibility with less data ports occupied. For data-multi- plex type cameras, 900 meters (3 000 ft) is the limit to use coaxial cable such as RG-59/U, BELDEN 9259 or equiva- lent....
Page 38
39 ■ Connection with the Monitors Connect the monitors to the MONITOR OUT connectors at the units rear panel with the coaxial cable. The connectors MONITOR OUT 1 to 4 are associated to Monitor 1 to 4. When you control the monitors from a PS· Data controller, the connectors MONITOR OUT are associ- ated to Unit 1 to 4. Martix Switcher Monitor 1 Monitor 2 Monitor 4 Monitor 3 2 14 3MONITOR OUT (A)(B)GND OFF ON(A)(B)GND OFF ON WV-CPR450 and others Set it to 2 or 4 (the same as the connected equipment). The...
Page 39
■ Connection with the Alarm Sensors Connect the sensor switches to the units alarm port, as shown in the example. Notes: •Alarm inputs that are simultaneous or with very short intervals will be ignored. Allow for at least 100 ms interval from one alarm input to the next. •Confirm the alarm sensor type (N.O. or N.C.) and con- figure the system through SETUP MENU (OSD) or WJ- SX150 Administrator Console. The factory setting is N.O. N.O.:Normally Open alarm contact N.C.:Normally Closed alarm contact •The...
Page 40
41 ■Connection with Digital Disk Recorder WJ-HD500 Series Note: Refer to a service manual procurable in your area, for details on the connection with a recorder (after the net- work board installation) to operate via LAN or the Internet. ●To Confirm the Images from a Recorder Connected to the Unit The following is the description of the connection between a recorder and this unit to confirm the images from the recorder. 1. Set the unit address of the recorder to 1. Then, confirm that the recorder’s...