Panasonic Dbs 824 Instructions Manual
Here you can view all the pages of manual Panasonic Dbs 824 Instructions Manual. The Panasonic manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 251
FFlExtension Transfer Recall Timer for Intercom Calls Extension Transfer Recall Timer for Intercom Calls Software VersionCPCS and CPC-M, Version 1 0 and higherAddress FFI 3## 21# (0-l2)# DescriptionWhen one extension transfers a call to another extension, the call will recall to Ihe transferring extension if it is not answeredThis timer determines how long the transferred call will ring before it recalls Programming FFl 3## 21# (0112)# f Timer Setting (Default=7 see the following table) Table l-25Recall...
Page 252
CO Delayed Ring TimerFFl CO Delayed Ring Timer Software VerGonCPCLS and CPC-M, Version 1 0 and higherAddress FFl 3# 22# (0-15)#Description CO Delayed Ringing allows a secondary phone to ring when incoming trunk calls to a primary phone are not answeredThis timer determines how long the trunk call will ring at the primary phone before it begins ringing at the secondary phone(When the secondary phone begins ringing, the primary phone will stop ringing ) Programming FFl 3## 22# (0:15)# Timer Setting...
Page 253
FFlCO Delayed Ring Timer Related ProgrammingDelayed Ring FFl 2# l# 21# (0 or l)# CO Delayed Day Ring AssignmentsFF4 5# (ExtPort)## (Trunk)# CO Delayed Day Ring Assignments for Hunt GroupsFF4 5# (HuntGrp)# (Trunk)# CO Delayed Night 1 Ring AssignmentsFF4 6# (Ext.Port)# (Trunk)# CO Delayed Night 1 Ring Assignments for Hunt GroupsFF4 6# (Hunffirp)# (Trunk)# CO Delayed Night 2 Ring Assignments FF4 9# 2# (ExtPort)# (Trunk)# CO Delayed Night 2 Ring Assignments for Hunt GroupsFF4 9# 2# (HuntGrp)# (Trunk)#...
Page 254
Extension Delayed Ring TimerFFl Extension Delayed Ring Timer Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3# 23# (0-15)# DescriptionExtension Delayed Ringing allows a secondary phone to ring when a primary phone is not answeredThis timer determines how long the primary phone will ring before the call begins ringing at the secondary phone Programming FFl 3## 23## (O+)#Timer Setting (Default=2 see the following table) Table 1-27Timer values for extension delayed ringing Number 0 1...
Page 255
FFlExtension Delayed Ring Timer Related ProgrammingExtension (BLF) Delayed Ring FF1 2# l# 27# (0 or l)#Extension Delayed Ring Table FF4 8# (TargetExtPort)# (SourceExtPort)# Issued 3/l/95DBS 824-10-400l-107
Page 256
Hunt Group No Answer TimerFFlHunt Group No Answer Timer Software VersionCPC-S and CPC-M, Version 1 0 and higher Address FFl 3# 24# (0-15)## DescriptionIf a call has entered a hunt group and the first extension to ring is not answered, this timer determines how long the extension will ring before the next idle extension in the hunt group begins ringing Programming FFl 3## 24# (0-15)# f Timer Setting (Default=2, see the following table) Table l-28 Hunt group no answer timer values NumberValue 0After 4...
Page 257
FFlAutomatic Day Mode Start Time Automatic Day Mode Start Time Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3## 25# HHMM# DescriptionAutomatic Day Mode allows the DBS 824 to go into “Day modeautomatically Automatic Night 1 Mode (FFl 3# I#) and Automatic Night 2 Mode (FFI 3# 29#) allow the DBS 824 to go into “Night 1” and “Night 2” mode automatically Programming To program automatic day mode Enter the time using the 24-hour format. The following example sets the time to830am FFl W...
Page 258
Automatic Day Mode Start TimeFFlIf both Auto Day and Auto Night modes are turned on the attendant NIGHT key cannot be usedWhen one Auto mode is turned on the mode cannot be reset by the NIGHT key until 3 minutes after the Auto mode is activated(When both Auto modes are set, the NIGHT key cannot be used ) Required Intervals Between Auto Day and Night ModesIf both Auto modes are set, the manufacturer recommends that the starting times of the modes differ by at least one hour l-110DBS 824-10-400Issued 3/l/95
Page 259
FFlWait Timer For Auto-Repeat Dialing Wait Timer For Auto-Repeat Dialing Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3# 26# (0-15)# DescriptionUse this program to set the amount of time the DBS 824 will wait before automatically redialing a number Programming FFl 3# 26# (0-15)# +Timer Setting (Default=8 see the following table) Table 1-29 Auto-Repeat dialing wait timer values Number 0 1 2 3 4 1 second 5 seconds 10 seconds 15 seconds 20 seconds Value 525seconds 630seconds...
Page 260
Wait Timer For Auto-Repeat DialingFFlBusy Tone (BT) Detection Timer FFl 3# 27#Dial Tone (DT) Detection Timer FFl 3# 28#CO Busy Tone (BT) Detection for Auto-Repeat Dialing FF2 (Trunk)# 22#l-112 DBS 824-l O-400Issued 3/l /95