Page 221
Baud Rate (Maintenance Port) Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 2# 9# 3## (l-4)## DescriptionThe data transmission speeds between Maintenance serial port CN2 and peripheral equipment can be set from 300 bits per second to 9600 bits per second Programming FFl 2# 9# 3## (114)# I=300 bps 2=1200 bps 3=24OO bps 4=9600 bps NotesChecking Communications ParametersBe sure to properly set all communication programming addresses when modifying any single address valueCommunication...
Page 222
Stop Bit Length (Maintenance Port) Software VersionCPCS and CPC-M, Version 1 0 and higherAddress FFl 2# 9# 4-N (193)# DescriptionThis program sets the length of the stop-bit parameter for a-ansmitted data over Maintenance serial port CN2 Programming FFI 2# 9# 4## (l-3)# l=l bit 2=15 bits 3=2 bits NotesChecking Communications ParameterBe sure to properly set all communication programming addresses when modifying any single address valueCommunication parameters for Maintenance are set with addresses FF12#...
Page 223
FFlData Length (Maintenance Port) Data Length (Maintenance Port) Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 2# 9# !% (3 or 4)## DescriptionThis program sets the length of the transmitted data suing at 7 or 8 bits, over Maintenance serial port CN2 Programming I 3=7 bits 43 bits NotesChecking Communications ParametersBe sure to properly set all communication programming addresses when modifying any single address value Communication parameters for Maintenance are set with addresses...
Page 224
Maintenance Serial POR Flow Control (XON / XOFF)FFlMaintenance Serial Port Flow Control (XON / XOFF) Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 2# 9# 6# (0 or l)# DescriptionUse this address to determine whether the DBS 824 system will control the flow of data between it and the device connected to the Maintenance serial port (CN2) ‘ XON/XOFF’ (if activated in this address) is a software switch that will temporarily stop the flow of data when the device s memory buffer...
Page 225
FFlAutomatic Night 1 Mode Start Time System Timers Automatic Night 1 Mode Start Time Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3## 1# (OOOO-2359)# DescriptionThis option sets a time for the DBS 824 to automatically switch from ‘Day to ‘Night 1’ mode This program uses the 24-hour time format. Programming To set the automatic Night 1 mode start time FFl 3# l# (000012359)# t Night 1 Mode Start Time (in 24-hour format) FFl 3# l# CONF ON/OFF To disable the automatic Night 1 mode...
Page 226
Attendant Hold Recall Timer for CO CallsFFlAttendant Hold Recall Timer for CO Calls Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3# 2# (O-12)# DescriptionThis timer determines how long a trunk call can be held by the attendant(s) before it will recall Programming FFl 3# 2# (O-12)# t Recall Timer (Default=l, see table below) Table 1-7Recall timer v&es for attendant-held CO calls Number 0 1 No recall 20 secondsValue 12-I 40secondsI 1 60 seconds 1 80 secondsI 1 100 seconds 6120...
Page 227
FFlExtension Hold Recall Timer for CO Calls Extension Hold Recall Timer for CO Calls Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3## 3# (0012)#Description This timer determines how long a hunk call will be held by an extensionbefore it will recall Programming FFl 3# 3## (0912)# fRecall Timer (Default=7 see the following table) Table I 8Recall tier values for extension-held CO calls 11220 seconds 12240 seconds Related Programming Extension Hold Recall Tier for Intercom CallsFFl 3#...
Page 228
Attendant Transfer Recall Timer for CO CallsFFl Attendant Transfer Recall Timer for CO Calls Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FFl 3# 4# (0-12)# DescriptionWhen an attendant transfers a trunk call to an extension or hunt group, the transferred call will recall to the attendant if it is not answeredThis timer determines how long a transferred trunk call will go unanswered before it recalls Programming FFl 3# 4## (0112)# t Recall Timer (Default=1 see the following table)...
Page 229
FF?txtension I rawer Hecall I imer for CO Calls Extension Transfer Recall Timer for CO Calls Software VersionCPC-S and CPC-M, Version 1 0 and higher Address FFl 3# 5# (o-12)# DescriptionWhen an extension aansfers a trunk call to another extension or to a hunt group, the transferred call will recall to the extension if it is not answered This timer determines how long a transferred trunk call will go unanswered before it recalls Programming FFl 3# 5# (0112)# + Recall Timer (Default=7 see the following...
Page 230
Attendant Park Hold Recall TimerFFl Attendant Park Hold Recall Timer Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress FF1 3# 6## (0-12)# DescriptionAn attendant phone can use up to 10 Call Park Numbers (00-09) to hold trunk callsThese park numbers can be assigned to an FF key or accessed by placing a call on hold, then dialing 7501-7509 This program determines how long a parked call will be held before it recalls Programming FFl W 6## (0112)# f Recall Timer (Default=1 see the following...