FFlCO-to-CO Talk Mode Control
CO-to-CO Talk Mode Control
Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# l# 38## (0 or l)#
DescriptionUse this address to determine whether the DBS 824 system will use an
internal conference circuit for trunk-to-trunk conference calls or whether it
will connect the trunks directlyThe CO-to-CO Talk mode is entered via the Call Forward-Outside feature or
the DISA Outgoing functionIf an audio loop-back problem occurs when
trunks are connected directly,...

Page 192

Parity Check (SMDR)FFl
SMDR Data (Serial Port CNl)
Parity Check (SMDR)
Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# l# (0 or l)##
DescriptionThis program determines whether the DBS 824 uses parity checking over
serial port 
CNl, which is normally dedicated for SMDR
If this address is set to “on,” use 
FFl 2# 2# 2# (0 or l># to select even or odd
PetY
Programming
I
I
FFl 2# 2# l# (0 or l)#
f
O=Turns off the parity check
l=Turns on the parity check
Related ProgrammingOdd/Even...

Page 193

FFlOdd/Even Parity (SMDR)
Odd/Even Parity (SMDR)
Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 2# (0 or l)##
DescriptionIf the parity check for SMDR serial port CNl has been set (FF12# 2# l#),
this option determines whether the check is based on an even count or an odd
count.
Programming
11
FFl 2# 2# 2# (0 or l)#
t
O--odd parityl=Even parity
NotesChecking Communications ParametersBe sure to properly set all
communication programming addresses when modifying any single address...

Page 194

Baud Rate (SMDR)FFl
Baud Rate (SMDR)
Software Version
CPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 3# (l-4)#
DescriptionThe data transmission speeds between SMDR serial port CNl and peripheral
equipment can be set from 300 bits per second to 9600 bits per second
Programming
FFl 2W 2# 3## (54)#
f
1=300 bps
2=1200 bps
3=2400 bps
4=9600 bps
NotesChecking Communications ParametersBe sure to properly set all
communication programming addresses when modifying any 
single address
valueCommunication...

Page 195

FFlStop Bit Lenqth (SMDR)
Stop Bit Length (SMDR)
Software VersionCPGS and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 4## (l-3)#
DescriptionThis program sets the length of the stop-bit parameter for transmitted data
over SMDR serial port 
CNl
Proghmming
FFl 2# 2# 4## (1 to 3)#
t
l=l bit
2=I 5 bits
3=2 bits
NotesChecking Communications ParametersBe sure to properly set all
communication programming addresses when modifying any single address
valueCommunication parameters for SMDR are set with...

Page 196

Data Length (SMDR)FFl
Data Length (SMDR)
Software VerskdPC=S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 5# (3 or 4)#
DescriptionThis program sets the length of the transmitted data string at 7 or 8 bits, over
SMDR serial port 
CNl
Programming
II
FFl 2# 2# 5## (3 or 4)#
t
3=7 bits
4=8 bits
NotesChecking Communicaticins ParametersBe sure to properly set all
communication programming addresses when modifying any single address
valueCommunication parameters for SMDR are set with addresses 
FF1 2#...

Page 197

FFlSMDR Serial Port Flow Control (XON / XOFF)
SMDR Serial Port Flow Control (XON / XOFF)
Software Version
CPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 6# (0 or l)#
DescriptionUse this address to determine whether the DBS 824 system will control the
flow of data to the SMDR device connected to serial port 
CNl
If “XON/XOFF” is activated in this address, the DBS 824’s software will stopthe flow of data when the SMDR device 
s memory buffer becomes full and
resume the flow when the buffer...

Page 198

SMDR Printing Mode 1 Outbound and InboundFFl
SMDR Printing Mode 1: Outbound and Inbound
Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 7# (0 or l)#
DescriptionThe SMDR printer can record data for only outgoing calls or for both
outbound and inbound calls
Progiamming
FFl 2# 2# 7# (0 or l)#
f
O=Outbound only
kInbound and outbound
NotesActivating SMDR Mode after Using the Bus Monitor ModeLf the DBS 824is in Bus Monitor Mode, the SMDR Mode must be reactivated to resume
SMDR output....

Page 199

FFlSMDR Printing Mode 2. Long-Distance and Local Calls
SMDR Printing Mode 2: Long-Distance and Local Calls
Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
FFl 2# 2# 8# (0 or l)#
DescriptionThe SMDR printer can record data on only long-distance calls or on all types
of outbound calls
Pro$ramming
FFl 2# 2# 8# (0 or l)#
t
O=Long-distance only
l=Local and long-distance
Issued 3/l /95DBS 824-l O-400Page l-51 

Page 200

SMDR Printing Mode 3 Header TitleFFl
SMDR Printing Mode 3: Header Title
Software VersionCPC-S and CPC-M, Version 1 0 and higherAddress 
FF1 2# 2# 9# (0 or l)#
DescriptionTitles such as “Time,” “Duration,” and “COW are printed every 60 lines on
the SMDR report if this feature is enabled
Programming
FFl 2# 2# 9# (0 or l)#
t
O=Turns off tlie header
l=Turns on the headerPage l-52