Page 271
Problems with optional equipment / 271 P0992669 03Compact ICS 6.0 Installer Guide External paging 1. Use the Button Inquiry feature (²¥â) to verify the feature of a programmable memory button. 2. Check the wiring between the 50-pin connector and the paging amplifier or between the connections shown in the external paging wiring chart. External paging wiring 3. Test external paging ²ßÛ to ensure that it is working. The nominal output signal from the Norstar ICS is 100 mV rms across 600 Ω. Music on...
Page 272
272 / Problems with optional equipment Compact ICS 6.0 Installer GuideP0992669 03 4. Check the wiring between the music source and the 50-pin connector. See the wiring charts in the Installation section. 5. Ensure that the music source is turned on, is operational, and the volume control is set properly. 6. Any music source with a low-output impedance (for example, less than 3,300 ohms) can be connected. The output level must be less than one volt.
Page 273
Problems with Trunk Cartridges / 273 P0992669 03Compact ICS 6.0 Installer Guide Problems with Trunk Cartridges Check first for user configuration problems, then wiring and programming errors before replacing Norstar equipment. Trunk Cartridge trouble 1. Check that the cartridge is properly inserted in the ICS. 2. Run a Maintenance session to ensure that the cartridge is not disabled. If the problem persists: 1. If AC power is present and the LED indicator on the ICS is off, see the section on ICS down...
Page 274
274 / Problems with BRI service Compact ICS 6.0 Installer GuideP0992669 03 Problems with BRI service Each LED on front of a BRI-ST or BRI-U Card corresponds with a loop, or indicates an overall state of the BRI connections. The BRI card is connected to the ISDN network (U-loop) but the LED for one of more loops is not lit Possible problem The physical connection or configuration for the network connection is not correct (no Layer 1). Solution 1. Verify the wiring from the network to the distribution...
Page 275
Problems with BRI service / 275 P0992669 03Compact ICS 6.0 Installer Guide “Out of service” is displayed when a BRI line is selected (LED for loop is lit) Possible problem The loop is configured incorrectly. Layer 1 is present but Layers 2 and 3 are not working. Solution 1. Verify that the SPIDs and Network DNs are programmed correctly in Hardware. 2. Verify that the loop and lines are provisioned. All the LEDs on a BRI Card are flashing Possible problem The card is not configured properly. Solution...
Page 276
276 / Problems with BRI service Compact ICS 6.0 Installer GuideP0992669 03 Caller hears one ring and then a fast busy signal when placing a call on a BRI line Possible problem CACH or EKTS, which are not supported by Compact ICS, is included in the ISDN services package. Solution 1. Contact your service provider and ensure that CACH or EKTS are not part of the ISDN services package. These services must be turned off at the switch. 2. Verify that the Network DNs have been programmed correctly, and...
Page 277
Problems with the NT1 / 277 P0992669 03Compact ICS 6.0 Installer Guide Problems with the NT1 The table gives the meaning of the indicators found on the stand alone NT1 manufactured by Nortel. Other models or makes of NT1 may have different indicators. For more information about the NT1, see the ISDN chapter. NT1 status indicators IndicatorStateMeaning off on flashingpower is unavailable power is available system is on backup power S or Toff on flashingnormal operation no synchronization with...
Page 278
278 / ICS down Compact ICS 6.0 Installer GuideP0992669 03 ICS down If AC power is present and the indicator light on the ICS is off, replace the fuse in the ICS (see illustration on next page). 1. Disconnect all central office and station lines from the ICS. Power down the ICS by unplugging it. 2. After powering down the ICS, use fingernails or screwdrivers to pinch the tabs on the fuse drawer and remove it from the ICS. The cables can easily and safely be pushed aside to reach the fuse drawer. 3....
Page 279
ICS down / 279 P0992669 03Compact ICS 6.0 Installer Guide Changing a fuse Fuse drawer Bottom view of ICS Fuse
Page 280
280 / Problems for network or remote users Compact ICS 6.0 Installer GuideP0992669 03 Problems for network or remote users Remote feature code gets no response Possible problem A Norstar user has called into another Norstar system and is trying to activate a remote feature but gets no response after dialing the feature code. Solution 1. If a COS password is needed for remote access, make sure the user has entered the appropriate password. 2. Make sure that the remote caller is dialing the feature code...