Nortel Compact Ics 6.0 Installer Guide
Here you can view all the pages of manual Nortel Compact Ics 6.0 Installer Guide. The Nortel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 301
Module status / 301 P0992669 03Compact ICS 6.0 Installer Guide Checking the state of a module Start from the module inventory display, which shows the number of Trunk Cartridges connected to the module you chose (for example, KSU: 2 cards ). 1. Press STATE. The state of the module is shown on the display. Some examples of this display are shown on the following page. 2. Press OK to return to the module inventory display. How the module or cartridge state is shown on the display ExampleState of...
Page 302
302 / Module status Compact ICS 6.0 Installer GuideP0992669 03 Checking the state of a cartridge Start from the display that shows the number of lines connected to the Trunk Cartridge you chose (for example, Card 1: 4 lines). 1. Press STATE. The display shows the state of the cartridge. Some examples of this display are shown in the previous table. 2. Press ‘ or “ to check the other Trunk Cartridges. 3. If required, you can disable or enable the cartridge. (See the procedures in the following two...
Page 303
Module status / 303 P0992669 03Compact ICS 6.0 Installer Guide Returning to the beginning From any display showing the state of the module or cartridge: 1. Press OK. 2. Press – until the display shows Module status.
Page 304
304 / System test log Compact ICS 6.0 Installer GuideP0992669 03 System test log The System test log shows you a list of diagnostic test results, audits, event messages, and alarm codes. By using this feature you can: check the items in the log check the current alarm (if there is one) check when each item in the log occurred check the number of consecutive occurrences of an event or an alarm erase the log The System test log holds a maximum of 20 items. You should check and record these items at...
Page 305
System test log / 305 P0992669 03Compact ICS 6.0 Installer Guide All alarms are recorded as items in the System test log. Checking when each item in the log occurred Start with any display showing a log item: 1. Press TIME. The display briefly shows the date and time. 2. Write the date and time on the System test log record. Checking the number of consecutive repetitions of an event or alarm If REPEAT appears under a display showing a log item: Press REPEAT. The display shows the number of...
Page 306
306 / System administration log Compact ICS 6.0 Installer GuideP0992669 03 System administration log The System administration log keeps a record of administrative events such as system initialization, configuration sessions in which a change was made, invalid password attempts, and password changes. By using this feature you can: check the items in the log erase the log check when each item in the log occurred The System administration log holds a maximum of ten items. Erase the log after dealing...
Page 307
System administration log / 307 P0992669 03Compact ICS 6.0 Installer Guide Checking when each item in the log occurred Start with any display showing a log item: 1. Press TIME. The display briefly shows the date and time. 2. Write the date and time on the System administration log record. Erasing the log Start with the display reading Items in log:. 1. Press ERASE. The display shows Erase log? 2. Press YES. If no new items have been added since the list was entered, the display shows Log erased. OR...
Page 308
308 / Provisioning Compact ICS 6.0 Installer GuideP0992669 03 Provisioning Provisioning applies only to BRI loops and lines. It allows you to place loops and lines in or out of service, either before or after the BRI Cards have been installed in the ICS. When you provision a loop, ISDN terminals on the loop can be used to make outgoing calls or receive incoming calls (S or U-LT loop), or lines are available for use by the devices attached to the system (T, S, or U-NT loop). When you are configuring...
Page 309
Alarm codes / 309 P0992669 03Compact ICS 6.0 Installer Guide Alarm codes The Norstar ICS generates alarm codes after system disconnections or after certain anomalies in system operation. All alarm codes appear at the Alarm telephone and in the System test log of a Maintenance session. For a complete description of alarm and event codes, you may order an Alarm and Event Code Manual from your service provider. The following figure shows an alarm code appearing on a Norstar Alarm telephone display. If...
Page 310
310 / Alarm codes Compact ICS 6.0 Installer GuideP0992669 03 5. Press CLEAR to clear the alarm. An alarm code may not be displayed until two minutes after it has been triggered. If the ICS is without power when the alarm is triggered, the alarm code is not displayed until two minutes after the power is restored to the ICS. For a complete list of Norstar alarms, consult the Norstar Alarm & Event Code Manual. Displays Example displayMeaningPossible causes Alarm: 10All ICS devices disconnected.The...