Page 311
Alarm codes / 311 P0992669 03Compact ICS 6.0 Installer Guide “X” = DS-30 port number (1-8) “Y” = Trunk Cartridge number (numbered from left to right) “Z” = Trunk port number Alarm troubleshooting Refer to the previous table before following these procedures. Alarm: 10 1. Check to see if there is a device connected to the ICS (that has a port number beginning with the number 1). 2. If there are no devices connected to the ICS, connect one and then press CLEAR. 3. If there are any devices connected to...
Page 312
312 / Alarm codes Compact ICS 6.0 Installer GuideP0992669 03 Alarm: 52-X-Y 1. Check all connections to the Trunk Cartridge. 2. Check that the proper Trunk Cartridge is inserted in the appropriate slot of the ICS. 3. Remove and re-install the Trunk Cartridge. 4. If the alarm persists, replace the Trunk Cartridge with another Trunk Cartridge of the same type. Alarm: 61-X-Y 1. Check that the proper Trunk Cartridges are inserted in the proper slots of the ICS. 2. Enter programming and look under the...
Page 313
Alarm codes / 313 P0992669 03Compact ICS 6.0 Installer Guide Alarm: 74 Ensure an Expansion Cartridge with Clocking or Clocking Cartridge is installed in the ICS. Alarm: 75 Check the connection to your ISDN service provider.
Page 314
314 / Event messages Compact ICS 6.0 Installer GuideP0992669 03 Event messages Event messages appear as items in the System administration log or the System test log of the Maintenance session. Most of these event messages can only be caused by an unusual combination of events, and should rarely occur. Each event is assigned a severity number. An S preceding this number, S4 for example, may appear in the event message. S9 is the most severe. If the Log is full, new event messages with a higher...
Page 315
Event messages / 315 P0992669 03Compact ICS 6.0 Installer Guide Displays Event messageThe event message is recorded when… EVT196 S4there was a software error on the built-in modem EVT197 S4system operation is slow or there was a software error with the auto-attendant feature EVT210-YYYZ S4Loopback test YYY on Trunk Cartridge Z has been started EVT211-YYYZ S4Loopback test YYY on Trunk Cartridge Z has been stopped EVT220-21 S4the System administration log has been cleared by the DN (21 in this...
Page 316
316 / Event messages Compact ICS 6.0 Installer GuideP0992669 03 EVT418 S7a DN change is successful EVT419 S2the time setting has been changed EVT421 S8a DN change failed EVT422-21 S6a length change by the DN (21 in this example) has been requested EVT423-21 S6an individual DN change has been requested by the DN (21 in this example) EVT425 S6an attempt has been made to add a DN or access code which is already in use by the system EVT448 S8the system has started to copy data to a range of telephones...
Page 317
Event messages / 317 P0992669 03Compact ICS 6.0 Installer Guide Event message 799 Event message 799 indicates a call processing error has occurred on an ISDN line. The event number is followed by a number representing the line or loop number, and a code for the type of error. EVT799-XXXX YYS7In this example, the error has occurred on line XXX and the error code is 0A. Error codeMeaning 01Internal software error. Cannot acquire the B-channel from the B-channel arbitrator. 02Internal software error....
Page 318
318 / Event messages Compact ICS 6.0 Installer GuideP0992669 03 Displays You should rarely see any event messages that are not described in the section entitled Significant event messages. If you do see one of these event messages, the Norstar system has followed its normal recovery from an unusual combination of system events. Although the problem is not a serious one, repeated occurrences of the event number should be reported as soon as possible. As a result of some events, the Norstar system...
Page 319
Event messages / 319 P0992669 03Compact ICS 6.0 Installer Guide 151Yes615-629No 152No630Yes 160-164No631-646No 170-173No800-802No 196-211No803Yes 220 (Admin log)No804-807No 221-222No808Yes 223 (Admin log)Yes809No 224Yes810Yes 225-228No811-820No 229 (Admin log)Yes823Yes 230-235No824-825No 245-248No883No 250-256No900No 260-271No940-943No 280-283No950-989No Event MessageSystem RestartEvent MessageSystem Restart
Page 320
320 / Tests Compact ICS 6.0 Installer GuideP0992669 03 Tests Norstar allows you to run a test which verifies the integrity of the installation wiring for Norstar sets. In addition, you can evaluate the transmission quality of a BRI loop through your service provider using a loopback test. Loopback test The loopback test for BRI lines loops the incoming BRI payload back to the local exchange (service provider) for evaluation of the transmission quality. Loopback tests should be conducted only with...