Home > NEC > Communications System > NEC Xen Ipk Features And Specifications Manual

NEC Xen Ipk Features And Specifications Manual

Here you can view all the pages of manual NEC Xen Ipk Features And Specifications Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 541

Features and Specifications Manual S13 – 533
Doc. No. 8201 - Release 1.0
July 2003
Station Camp-OnS-13
FEATURE 
DESCRIPTIONThe Station Camp-On feature allows a call to be transferred to a busy
station. When the station receiving the camp-on tone becomes idle, the call
rings and can be answered. After a programmed time interval, unanswered
camp-on calls recall to the station that initiated the camp-on.
SYSTEM 
AVAILABILITYTerminal Type
All terminals.
Required Components
None.
OPERATING 
PROCEDURES
1....

Page 542

July 2003 NEC Business Solutions Ltd
534 – S13Station Camp-On
Doc. No. 8201 - Release 1.0
July 2003
1. Press the hookswitch momentarily, and receive second dial tone.
2. Dial the station number to where call is to be transferred.
3. Hang up.
SERVICE 
CONDITIONSGeneral
	If the Camp-On is placed after Tone Override, camp-on tone is
provided.
	Station and Attendant Camp-On Recall timers can be assigned
separately.
	Camp-On Tone receive is assigned in Station Class of Service
assignment.
To originate a...

Page 543

Features and Specifications Manual S14 – 535
Doc. No. 8201 - Release 1.0
July 2003
Station HuntingS-14
FEATURE 
DESCRIPTIONThe Station Hunting feature distributes internal and outside calls to multiple
stations in a Station Hunt group. When a station number programmed as a
Station Hunting master number is dialled, and this number is busy, the call
is forwarded to another station in that hunt group.
SYSTEM 
AVAILABILITYTerminal Type
All terminals.
Required Components
None.
OPERATING 
PROCEDURES
1. Lift...

Page 544

July 2003 NEC Business Solutions Ltd
536 – S14Station Hunting
Doc. No. 8201 - Release 1.0
July 2003
General
	A maximum of 120 stations in the Xen IPK Expanded system or 32 in
the Xen IPK Basic system, can be assigned to a hunt group.
	The station master number is an actual station. If this station is busy,
the call is forwarded to the next programmed answering station.
	Linear hunt (consecutively search from the lead station) is provided.
	DIT/ANA calls to Station Hunting master numbers follow the...

Page 545

Xen IPK Features and Specifications Manual
Features and Specifications Manual S14 – 537
Doc. No. 8201 - Release 1.0
July 2003
GUIDE TO 
FEATURE 
PROGRAMMING
Order
and
Shortcut
System Data NameMemory 
BlockFunction
1-8-07
Attendant
Page-Line 
Key1-8-08
Station
Page-Line 
Key
¶+BTT4Intercom Master Hunt Number Selection4-14
¶+BTT4Intercom Master Hunt Number Forward 
Assignment4-15
¶+AASCD (Simplified Call Distribution) Pilot Number 
Assignment1-8-29
¶+AASCD Group Agent Assignment 1-8-30
4When the system is...

Page 546

July 2003 NEC Business Solutions Ltd
538 – S14Station Hunting
Doc. No. 8201 - Release 1.0
July 2003
THIS PAGE INTENTIONALLY LEFT BLANK 

Page 547

Features and Specifications Manual S15 – 539
Doc. No. 8201 - Release 1.0
July 2003
Station Message Detail 
Recording (SMDR)S-15
FEATURE 
DESCRIPTIONAn optional MIFM-U(  ) ETU provides detailed outside call records of
system telephone usage. This supports cost control by identifying telephone
users, trunk usage, and digits dialled. SMDR enables connection of call
accounting equipment to audit local and long distance telephone bills.
SYSTEM 
AVAILABILITYTerminal Type
All terminals:
1. Incoming CO/PBX Call...

Page 548

July 2003 NEC Business Solutions Ltd
540 – S15 Station Message Detail Recording (SMDR)
Doc. No. 8201 - Release 1.0
July 2003
General
	If the printer or other I/O devices fail to operate, approximately 100 call
records are saved in the MIFM-U( ) ETU buffer. When the
buffer becomes full, the first call record is lost and the last call record
is stored.
	Call record data provides the following information:
Start Time, Trunk Number, Trunk Group, Type of Call, Station Number,
Duration, Number Dialled, LCR,...

Page 549

Xen IPK Features and Specifications Manual
Features and Specifications Manual S15 – 541
Doc. No. 8201 - Release 1.0
July 2003
	DISA (Both incoming and outgoing are printed). Format shown is
printed if incoming caller hangs up first. Format is reversed if called
party hangs up first.
07/03/98
09:00 05-12IC999234
ABCDEF
00:15:32
G
	                                       
    D100 
	                                               J
07/03/98
09:0008- 05-12OG99900
ABCDE1E2
00:15:32
102885167537000 
GH...

Page 550

July 2003 NEC Business Solutions Ltd
542 – S15 Station Message Detail Recording (SMDR)
Doc. No. 8201 - Release 1.0
July 2003
	FTransferred Station Number
22-digit Station Number in System Programming
33-digit Station Number in System Programming
44-digit Station Number in System Programming
	G Call Duration
00 = hour
15 = minutes
32 = seconds 
	H Number Dialled
Maximum of 24 Characters
Incoming Caller ID Number = 9727517622
	I Account Code Entry:1234567890
Maximum of 16 Characters
Forced Account Code:...