Page 281
Features and Specifications Manual D11 – 271 Doc. No. 8201 - Release 1.0 July 2003 Direct Paging AccessD-11 FEATURE DESCRIPTIONThe Attendant Add-On Console Direct Station Selection/Busy Lamp Field (DSS/BLF) keys allow direct access to each of the Internal, External, and All Call Paging. The programmable Feature Access and One-Touch keys on the Multiline Terminals can also be used for Direct Paging Access. SYSTEM AVAILABILITYTerminal Type All Multiline Terminals and Attendant Add-On Consoles . Required...
Page 282
July 2003 NEC Business Solutions Ltd 272 – D11Direct Paging Access Doc. No. 8201 - Release 1.0 July 2003 Restrictions All Internal/External Page Access cannot be programmed to a key on the Attendant Add-On Console. General If a Direct Paging Access key for All Internal Zone or Internal Zone Page on the Attendant Add-On Console is pressed, a paging announcement is made over the speakers of all idle Multiline Terminals programmed in a zone. Paging access through external speakers is available if a...
Page 283
Features and Specifications Manual D12 – 273 Doc. No. 8201 - Release 1.0 July 2003 Direct Station SelectionD-12 FEATURE DESCRIPTIONThe Direct Station Selection (DSS) feature allows all Multiline Terminal users to make station calls by pressing only one key. SYSTEM AVAILABILITYTerminal Type All Multiline Terminals and Attendant Add-On Consoles. Required Components None. OPERATING PROCEDURES 1. Press the programmed Feature Access key. Hear ringback tone or make voice announcement. 2. When the called...
Page 284
July 2003 NEC Business Solutions Ltd 274 – D12Direct Station Selection Doc. No. 8201 - Release 1.0 July 2003 SERVICE CONDITIONSGeneral When station numbers are assigned to Feature Access or One-Touch keys on a Multiline Terminal, the user can press the DSS key to call the station. When a station is called by pressing a DSS key and that station is busy, a call waiting tone is sent to the calling station. Any other station that calls the original busy station receives a busy tone while the first calling...
Page 285
Features and Specifications Manual D13 – 275 Doc. No. 8201 - Release 1.0 July 2003 Distinctive RingingD-13 FEATURE DESCRIPTIONThe Distinctive Ringing feature distinguishes between internal and incoming outside calls. This feature provides distinct ring audible signals and patterns. Distinctive Ring can be assigned on a per trunk or per telephone basis. SYSTEM AVAILABILITYTerminal Type All terminals, except Single Line Telephones connected to an AP(R)- R( ) Unit. Required Components None. OPERATING...
Page 286
July 2003 NEC Business Solutions Ltd 276 – D13Distinctive Ringing Doc. No. 8201 - Release 1.0 July 2003 General Incoming outside calls and internal calls provide flexible ringing tones and patterns. Distinctive ringing patterns are as follows: 1. Internal ring tone provides a distinctive ringing pattern of 1 second ON/2 seconds OFF (system default). 2. Incoming CO/PBX outside calls are assigned synchronous ring. The ringing pattern sent from the exchange connected to the CO PBX/Centrex lines is...
Page 287
Xen IPK Features and Specifications Manual Features and Specifications Manual D13 – 277 Doc. No. 8201 - Release 1.0 July 2003 GUIDE TO FEATURE PROGRAMMING Incoming Trunk Call Priority? M. B. 4- 57 Ca ll? D IT, AA, or DID M.B. 4-55? M.B. 3-67? CO TEL Yes No Ca ll? D IT, AA, or DID – (N on e) M. B. 3- 67 ? A~H Ye s No A~H – ( Non e) To ne F oll ows M.B.3-07 – (None) Ton e Fo llo ws M.B.3-07 To n e F o l l o w s M. B . 4-9 1Individual for R inging Port CO/PBX Trunk? M. B. 1 -1- 59 Synchronous?...
Page 288
July 2003 NEC Business Solutions Ltd 278 – D13Distinctive Ringing Doc. No. 8201 - Release 1.0 July 2003 ¶+BTS4Distinctive Ringing by Telephone or CO Selection1-1-28 ¶+BCTCO/PBX Ringing Variation Selection 3-07 ¶+BTMTelephone Ringing Variation Selection 4-91 ¶+BCSCO Line Ringing Pattern Selection 1-1-51 ¶+BCSPBX Line Ringing Pattern Selection 1-1-52 ¶+ALNTie Line Delay Ring Pattern Selection 1-1-53 ¶+BMCO/PBX Incoming Ringing Alarm Time Selection 1-1-06 ¶+ALMTie Line Delay Ringing Time Selection 1-1-07...
Page 289
Features and Specifications Manual D14 – 279 Doc. No. 8201 - Release 1.0 July 2003 Do Not Disturb (DND)D-14 FEATURE DESCRIPTIONThe Do Not Disturb (DND) feature temporarily eliminates all audible signals for incoming calls to the station. This temporarily isolates the station from others in the system. SYSTEM AVAILABILITYTerminal Type All terminals. Required Components None. OPERATING PROCEDURES 1. PressTin idle mode. 2. Dial Access Code F0. 3. Press T. - OR - 4. Press the DND On/Off key. 1. Lift the...
Page 290
July 2003 NEC Business Solutions Ltd 280 – D14Do Not Disturb (DND) Doc. No. 8201 - Release 1.0 July 2003 1. Lift the handset or press P. 2. Dial DND cancel; DB(set at default). 3. Go on-hook or press P. 1. Press T. 2. Dial Access Code FH. 3. Press T. SERVICE CONDITIONSData Assignment At default, the system-wide cancel DND from Attendant Positions is not allowed. DND is allowed or denied in Class of Service. Restrictions Automatic Callback cannot be set to a station that is in DND mode. If DND and...