    							ND-46551 (E) CHAPTER 3
    Page 69
    Revision 2.0
    NAP-200-006
    Sheet 8/54
    Termination of Cables on the MDF
    * Major and minor alarm connections are used for external indications.
    Note 1:2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON.
    Note 2:4-wire type for Multiline Terminal/SN610 ATTCON.Table 006-3 LTC0-LTC2 MDF Cross Connection Information (Continued)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    D
    term/
    SN716 
    DESKCON 
    (4DLC) 
    Note 1Dterm/
    SN716 
    DESKCON 
    (2DLC) 
    Note 1Dterm 
    (4DLC) 
    Note 2SN610 
    ATTCON 
    (2DLC) 
    Note 2EXT. KEY/
    EXT. 
    RELAY
    (DK00)EXT.
    PA G E / M O H /
    BGM
    (4COT)
    38
    13BK-GN
    GN-BKGN
    RD
    4T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    39
    14BK-BR
    BR-BKBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    40
    15BK-SL
    SL-BKGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    41
    16YL-BL
    BL-YLBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    42
    17YL-OR
    OR-YLGN
    RD
    5T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    43
    18YL-GN
    GN-YLBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    44
    19YL-BR
    BR-YLGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    45
    20YL-SL
    SL-YLBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    46
    21VI-BL
    BL-VIGN
    RD
    6T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    47
    22VI-OR
    OR-VIBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    48
    23VI-GN
    GN-VIGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    49
    24VI-BR
    BR-VIBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    50
    25VI-SL
    SL-VIMN*
    MJ* 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 7 0
    Revision 2.0
    NAP-200-006
    Sheet 9/54
    Termination of Cables on the MDF
    (2) The figure below shows the LTC Connector Pin Arrangement.
    (a) PIM1 (LTC0 ~ LTC2)
    Figure 006-5  LTC Connector Pin Arrangement (PIM1)
    LTC2
    26 1 LEN0048
    LT06/AP0
    27 2 0049
    28 3 0050
    29 4 0051
    30 5 0052
    31 6 0053
    32 7 0054
    33 8 0055
    34 9 0056
    LT07/AP1
    35 10 0057
    36 11 0058
    37 12 0059
    38 13 0060
    39 14 0061
    40 15 0062
    41 16 0063
    42 17 0064
    LT08/AP2
    43 18 0065
    44 19 0066
    45 20 0067
    46 21 0068
    47 22 0069
    48 23 0070
    49 24 LEN0071
    50 25
    LTC0
    26 1 LEN0000
    LT00
    27 2 0001
    28 3 0002
    29 4 0003
    30 5 0004
    31 6 0005
    32 7 0006
    33 8 0007
    34 9 0008
    LT01
    35 10 0009
    36 11 0010
    37 12 0011
    38 13 0012
    39 14 0013
    40 15 0014
    41 16 0015
    42 17 0016
    LT02
    43 18 0017
    44 19 0018
    45 20 0019
    46 21 0020
    47 22 0021
    48 23 0022
    49 24 LEN0023
    50 MN 25 MJ
    LTC1
    26 1 LEN0024
    LT03
    27 2 0025
    28 3 0026
    29 4 0027
    30 5 0028
    31 6 0029
    32 7 0030
    33 8 0031
    34 9 0032
    LT04
    35 10 0033
    36 11 0034
    37 12 0035
    38 13 0036
    39 14 0037
    40 15 0038
    41 16 0039
    42 17 0040
    LT05
    43 18 0041
    44 19 0042
    45 20 0043
    46 21 0044
    47 22 0045
    48 23 0046
    49 24 LEN0047
    50 25
    0072
    LT09/AP30073
    0074
    LEN0075or 
    						
    							ND-46551 (E) CHAPTER 3
    Page 71
    Revision 2.0
    NAP-200-006
    Sheet 10/54
    Termination of Cables on the MDF
    Table 006-4  LTC0-LTC2 MDF Cross Connection Information
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    CO
    (4COT)2-WIRE 
    E&M TIE 
    LINE
    (2ODT)4-WIRE 
    E&M TIE 
    LINE
    (2ODT)DID
    (AUC)DID
    (4DIT)SLT
    (8LC)SLT
     (4LC)SLT
    (AUC)
    26 WH-BL GN
    1T0 T0 TxT0 T0 T0 T0 T0 T0
    1 BL-WH RD R0 R0 TxR0 R0 R0 R0 R0 R0
    27 WH-OR BK T1 RcvT0 T1 T1 T1 T1 T1
    2 OR-WH YL R1 RcvR0 R1 R1 R1 R1 R1
    28WH-GNGN T2T1TxT1 T2T2T2
    3 GN-WH RD R2 R1 TxR1 R2 R2 R2
    29 WH-BR BK T3 RcvT1 T3 T3 T3
    4 BR-WH YL R3 RcvR1 R3 R3 R3
    30 WH-SL GN T4
    5 SL-WH RD R4
    31 RD-BL BK T5
    6 BL-RD YL R5
    32 RD-OR GN T6
    7 OR-RD RD R6
    33 RD-GN BK T7
    8 GN-RD YL R7
    34 RD-BR GN
    2T0 T0 TxT0 T0 T0 T0 T0 T0
    9 BR-RD RD R0 R0 TxR0 R0 R0 R0 R0 R0
    35 RD-SL BK T1 T1 RcvT0 T1 T1 T1 T1 T1
    10 SL-RD YL R1 R1 RcvR0 R1 R1 R1 R1 R1
    36BK-BLGN T2 TxT1 T2T2T2
    11 BL-BK RD R2 TxR1 R2 R2 R2
    37 BK-OR BK T3 RcvT1 T3 T3 T3
    12 OR-BK YL R3 RcvR1 R3 R3 R3
    38 BK-GN GN T4
    13 GN-BK RD R4
    39 BK-BR BK T5
    14 BR-BK YL R5
    40 BK-SL GN T6
    15 SL-BK RD R6
    41 YL-BL BK T7
    16 BL-YL YL R7 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 7 2
    Revision 2.0
    NAP-200-006
    Sheet 11/54
    Termination of Cables on the MDF
    * Major and minor alarm connections are used for external indications.
    Note :When mounting the circuit card with cabling in LT09 slot, these pins must be used.
    When mounting the circuit card with cabling (except for PN-8LC/PN-8DLC) in LT02 slot, LT05 slot or LT08 slot,
    these pins can not be used.Table 006-4 LTC0-LTC2 MDF Cross Information (Continued)
    PINRU NN ING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    CO
    (4COT)2-WIRE 
    E&M TIE 
    LINE
    (2ODT)4-WIRE 
    E&M TIE 
    LINE
    (2ODT)DID
    (AUC)DID
    (4DIT)SLT
    (8LC)SLT
     (4LC)SLT
    (AUC)
    42 YL-OR GN
    3T0 T0 TxT0 T0 T0 T0 T0 T0
    17OR-YLRD R0R0TxR0R0R0R0R0R0
    43 YL-GN BK T1 RcvT0 T1 T1 T1 T1 T1
    18 GN-YL YL R1 RcvR0 R1 R1 R1 R1 R1
    44YL-BRGN T2T1TxT1 T2T2T2
    19 BR-YL RD R2 R1 TxR1 R2 R2 R2
    45 YL-SL BK T3 RcvT1 T3 T3 T3
    20 SL-YL YL R3 RcvR1 R3 R3 R3
    46 VI-BL GN
    Note
    T0 T0 TxT0 T0 T0 T4 T0 T0
    21BL-VI RD R0R0TxR0R0R0R4R0R0
    47 VI-OR BK T1 RcvT0 T1 T1 T5 T1 T1
    22 OR-VI YL R1 RcvR0 R1 R1 R5 R1 R1
    48VI-GNGN T2T1TxT1 T2T6T2
    23 GN-VI RD R2 R1 TxR1 R2 R6 R2
    49 VI-BR BK T3 RcvT1 T3 T7 T3
    24 BR-VI YL R3 RcvR1 R3 R7 R3
    50 VI-SL MN*
    25 SL-VI MJ* 
    						
    							ND-46551 (E) CHAPTER 3
    Page 73
    Revision 2.0
    NAP-200-006
    Sheet 12/54
    Termination of Cables on the MDF
    Note 1:2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON.
    Note 2:4-wire type for Multiline Terminal/SN610 ATTCON.Table 006-4 LTC0-LTC2 MDF Cross Connection Information (Continued)
    PINRU NN ING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    Multiline 
    Te r m i n a l /
    SN716 
    DESKCON
    (8DLC)
    Note 1Multiline 
    Te r m i n a l /
    SN716 
    DESKCON
    (4DLC)
    Note 1Multiline 
    Te rm i n a l /
    SN716 
    DESKCON
    (2DLC)
    Note 1Multiline
    Ter m in a l
    (4DLC)
    Note 2SN610
    AT T C O N
    (2DLC)
    Note 2EXT. KEY/
    EXT.
    RELAY
    (DK00)EXT.
    PAG E /
    MOH/BGM
    (4COT)
    26
    1WH-BL
    BL-WHGN
    RD
    1T0
    R0T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    27
    2WH-OR
    OR-WHBK
    YLT1
    R1T1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    28
    3WH-GN
    GN-WHGN
    RDT2
    R2T2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    29
    4WH-BR
    BR-WHBK
    YLT3
    R3T3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    30
    5WH-SL
    SL-WHGN
    RDT4
    R4RA0
    TA 0
    31
    6RD-BL
    BL-RDBK
    YLT5
    R5RB0
    TB0
    32
    7RD-OR
    OR-RDGN
    RDT6
    R6RA1
    TA 1
    33
    8RD-GN
    GN-RDBK
    YLT7
    R7RB1
    TB1
    34
    9RD-BR
    BR-RDGN
    RD
    2T0
    R0T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    35
    10RD-SL
    SL-RDBK
    YLT1
    R1T1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    36
    11BK-BL
    BL-BKGN
    RDT2
    R2T2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    37
    12BK-OR
    OR-BKBK
    YLT3
    R3T3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    38
    13BK-GN
    GN-BKGN
    RDT4
    R4RA0
    TA 0
    39
    14BK-BR
    BR-BKBK
    YLT5
    R5RB0
    TB0
    40
    15BK-SL
    SL-BKGN
    RDT6
    R6RA1
    TA 1
    41
    16YL-BL
    BL-YLBK
    YLT7
    R7RB1
    TB1 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 7 4
    Revision 2.0
    NAP-200-006
    Sheet 13/54
    Termination of Cables on the MDF
    * Major and minor alarm connections are used for external indications.
    Note 1:When mounting the circuit card with cabling in LT09 slot, these pins must be used.
    When mounting the circuit card with cabling (except for PN-8LC/PN-8DLC) in LT02 slot, LT05 slot or LT08 slot,
    these pins can not be used.
    Note 2:
    2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON.
    Note 3:
    4-wire type for Multiline Terminal/SN610 ATTCON.
    Table 006-4 LTC0-LTC2 MDF Cross Information (Continued)
    PINRU NN ING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    Multiline 
    Te r m i n a l /
    SN716 
    DESKCON
    (8DLC)
    Note 2Multiline 
    Te r m i n a l /
    SN716
    DESKCON
    (4DLC)
    Note 2Multiline 
    Te rm i n a l /
    SN716
    DESKCON
    (2DLC)
    Note 2Multiline
    Ter m in a l
    (4DLC)
    Note 3SN610
    AT T C O N
    (2DLC)
    Note 3EXT. KEY/
    EXT. 
    RELAY
    (DK00)EXT.
    PA G E / M O H /
    BGM
    (4COT)
    42 YL-OR GN
    3T0
    R0T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    17 OR-YL RD
    43 YL-GN BK
    T1
    R1T1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    18 GN-YL YL
    44 YL-BR GN
    T2
    R2T2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    19 BR-YL RD
    45 YL-SL BK
    T3
    R3T3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    20 SL-YL YL
    46 VI-BL GN
    Note 1
    T4
    R4T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    21 BL-VI RD
    47 VI-OR BK
    T5
    R5T1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    22 OR-VI YL
    48 VI-GN GN
    T6
    R6T2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    23 GN-VI RD
    49 VI-BR BK
    T7
    R7T3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    24 BR-VI YL
    50 VI-SL MN*
    25 SL-VI MJ* 
    						
    							ND-46551 (E) CHAPTER 3
    Page 75
    Revision 2.0
    NAP-200-006
    Sheet 14/54
    Termination of Cables on the MDF
    (1) C.O. Trunk
    (a) 4 Line C.O. Trunk (PN-4COT)
    Figure 006-6  MDF Cross Connection for a 4Line C.O. Trunk Card (PN-4COT)
    29T3294
    R3428
    T2283
    R2327
    T12726
    T026
    2
    1
    1R0 26T0
    2R1 27T1
    3R2 28T2
    4R3 29T3
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 T2 3 R2
    29 T3 4 R3LEN0000
    LEN0001
    LEN0002
    LEN0003
    LTC0 (J)MDF
    R01
    R12
    LEN0000      (No. 0)
    LEN0001      (No. 1)
    LEN0002      (No. 2)
    LEN0003      (No. 3)
    TO C.O. L INE
    TO C.O. L INE
    TO C.O. L INE
    TO C.O. L INE
    PIM0
    P PN-4COT
    LT00LTC0
    J 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 7 6
    Revision 2.0
    NAP-200-006
    Sheet 15/54
    Termination of Cables on the MDF
    (2) Tie Line Trunk
    (a) 4W E&M Trunk (PN-2ODT)
    Figure 006-7  MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT)
    1
    26
    2
    27
    3
    28
    4
    29TxR0
    TxT0
    RcvR0
    RcvT0
    TxR1
    TxT1
    RcvR1
    RcvT1MDF
    LEN0001      (No. 1)
    LEN0000      (No. 0)PIM0
    PN-2ODT
    LT00
    LEN0001      (No. 1)
    1
    26
    2
    27
    3
    28
    4
    29
    (Rcv Tip)
    (Rcv Ring)
    (M)
    TO TIE LINE
    JPLTC0
    LEN0000      (No. 0)
    08
    07
    06
    05
    04 M1
    03 E1
    02 M0
    01 E0(E)
    (Tx Tip)
    (Tx Ring)
    JCN1
    INSTALLATION CABLE
    Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
    Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT
    card. 
    						
    							ND-46551 (E) CHAPTER 3
    Page 77
    Revision 2.0
    NAP-200-006
    Sheet 16/54
    Termination of Cables on the MDF
    Figure 006-7  MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (Continued)
    M1
    E1
    M0
    E0LEN0001
    LEN0000
    CN1
    1 LTC CONNECTOR2 CN1 CONNECTOR
    (FRONT CONNECTOR)
    LEN0000
    LEN00011 TxR0 26 TxT0
    2 RcvR0 27 RcvT0
    3 TxR1 28 TxT1
    4 RcvR1 29 RcvT1
    (P)
    26 TxT0 1 TxR0
    27 RcvT0 2 RcvR0
    28 TxT1 3 TxR1
    29 RcvT1 4 RcvR1
    LTC0 (J) 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 7 8
    Revision 2.0
    NAP-200-006
    Sheet 17/54
    Termination of Cables on the MDF
    (b) 2W E&M (PN-2ODT)
    Figure 006-8  MDF Cross Connection for a 2W E&M Trunk Card (PN-2ODT)
    1
    26
    2
    27
    3
    28
    4
    29
    TO-10
    TO-9
    R0
    T0
    R1
    T1
    R2
    T2
    R3
    T3MDF
    LEN0001      (No. 1)
    LEN0000      (No. 0)PIM0
    PN-2ODT
    LT00
    LEN0001      (No. 1)
    1
    26
    2
    27
    3
    28
    4
    29
    (M)
    TO TIE LINE
    JPLTC0
    LEN0000      (No. 0)
    CN1
    08
    07
    06
    05
    04 M1
    03 E1
    02 M0
    01 E0(E)
    (Ring)
    (Tip)
    J
    INSTALLATION CABLE
    Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
    Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT
    card. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax2000 Ivs Small Platform System Manual