ND-46551 (E) CHAPTER 3 Page 69 Revision 2.0 NAP-200-006 Sheet 8/54 Termination of Cables on the MDF * Major and minor alarm connections are used for external indications. Note 1:2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON. Note 2:4-wire type for Multiline Terminal/SN610 ATTCON.Table 006-3 LTC0-LTC2 MDF Cross Connection Information (Continued) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE D term/ SN716 DESKCON (4DLC) Note 1Dterm/ SN716 DESKCON (2DLC) Note 1Dterm (4DLC) Note 2SN610 ATTCON (2DLC) Note 2EXT. KEY/ EXT. RELAY (DK00)EXT. PA G E / M O H / BGM (4COT) 38 13BK-GN GN-BKGN RD 4T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 39 14BK-BR BR-BKBK YLT1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 40 15BK-SL SL-BKGN RDT2 R2RA1 TA 1RA1 TA 1K5 K4T R 41 16YL-BL BL-YLBK YLT3 R3RB1 TB1RB1 TB1K7 K6T R 42 17YL-OR OR-YLGN RD 5T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 43 18YL-GN GN-YLBK YLT1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 44 19YL-BR BR-YLGN RDT2 R2RA1 TA 1RA1 TA 1K5 K4T R 45 20YL-SL SL-YLBK YLT3 R3RB1 TB1RB1 TB1K7 K6T R 46 21VI-BL BL-VIGN RD 6T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 47 22VI-OR OR-VIBK YLT1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 48 23VI-GN GN-VIGN RDT2 R2RA1 TA 1RA1 TA 1K5 K4T R 49 24VI-BR BR-VIBK YLT3 R3RB1 TB1RB1 TB1K7 K6T R 50 25VI-SL SL-VIMN* MJ*
CHAPTER 3 ND-46551 (E) Pag e 7 0 Revision 2.0 NAP-200-006 Sheet 9/54 Termination of Cables on the MDF (2) The figure below shows the LTC Connector Pin Arrangement. (a) PIM1 (LTC0 ~ LTC2) Figure 006-5 LTC Connector Pin Arrangement (PIM1) LTC2 26 1 LEN0048 LT06/AP0 27 2 0049 28 3 0050 29 4 0051 30 5 0052 31 6 0053 32 7 0054 33 8 0055 34 9 0056 LT07/AP1 35 10 0057 36 11 0058 37 12 0059 38 13 0060 39 14 0061 40 15 0062 41 16 0063 42 17 0064 LT08/AP2 43 18 0065 44 19 0066 45 20 0067 46 21 0068 47 22 0069 48 23 0070 49 24 LEN0071 50 25 LTC0 26 1 LEN0000 LT00 27 2 0001 28 3 0002 29 4 0003 30 5 0004 31 6 0005 32 7 0006 33 8 0007 34 9 0008 LT01 35 10 0009 36 11 0010 37 12 0011 38 13 0012 39 14 0013 40 15 0014 41 16 0015 42 17 0016 LT02 43 18 0017 44 19 0018 45 20 0019 46 21 0020 47 22 0021 48 23 0022 49 24 LEN0023 50 MN 25 MJ LTC1 26 1 LEN0024 LT03 27 2 0025 28 3 0026 29 4 0027 30 5 0028 31 6 0029 32 7 0030 33 8 0031 34 9 0032 LT04 35 10 0033 36 11 0034 37 12 0035 38 13 0036 39 14 0037 40 15 0038 41 16 0039 42 17 0040 LT05 43 18 0041 44 19 0042 45 20 0043 46 21 0044 47 22 0045 48 23 0046 49 24 LEN0047 50 25 0072 LT09/AP30073 0074 LEN0075or
ND-46551 (E) CHAPTER 3 Page 71 Revision 2.0 NAP-200-006 Sheet 10/54 Termination of Cables on the MDF Table 006-4 LTC0-LTC2 MDF Cross Connection Information PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE CO (4COT)2-WIRE E&M TIE LINE (2ODT)4-WIRE E&M TIE LINE (2ODT)DID (AUC)DID (4DIT)SLT (8LC)SLT (4LC)SLT (AUC) 26 WH-BL GN 1T0 T0 TxT0 T0 T0 T0 T0 T0 1 BL-WH RD R0 R0 TxR0 R0 R0 R0 R0 R0 27 WH-OR BK T1 RcvT0 T1 T1 T1 T1 T1 2 OR-WH YL R1 RcvR0 R1 R1 R1 R1 R1 28WH-GNGN T2T1TxT1 T2T2T2 3 GN-WH RD R2 R1 TxR1 R2 R2 R2 29 WH-BR BK T3 RcvT1 T3 T3 T3 4 BR-WH YL R3 RcvR1 R3 R3 R3 30 WH-SL GN T4 5 SL-WH RD R4 31 RD-BL BK T5 6 BL-RD YL R5 32 RD-OR GN T6 7 OR-RD RD R6 33 RD-GN BK T7 8 GN-RD YL R7 34 RD-BR GN 2T0 T0 TxT0 T0 T0 T0 T0 T0 9 BR-RD RD R0 R0 TxR0 R0 R0 R0 R0 R0 35 RD-SL BK T1 T1 RcvT0 T1 T1 T1 T1 T1 10 SL-RD YL R1 R1 RcvR0 R1 R1 R1 R1 R1 36BK-BLGN T2 TxT1 T2T2T2 11 BL-BK RD R2 TxR1 R2 R2 R2 37 BK-OR BK T3 RcvT1 T3 T3 T3 12 OR-BK YL R3 RcvR1 R3 R3 R3 38 BK-GN GN T4 13 GN-BK RD R4 39 BK-BR BK T5 14 BR-BK YL R5 40 BK-SL GN T6 15 SL-BK RD R6 41 YL-BL BK T7 16 BL-YL YL R7
CHAPTER 3 ND-46551 (E) Pag e 7 2 Revision 2.0 NAP-200-006 Sheet 11/54 Termination of Cables on the MDF * Major and minor alarm connections are used for external indications. Note :When mounting the circuit card with cabling in LT09 slot, these pins must be used. When mounting the circuit card with cabling (except for PN-8LC/PN-8DLC) in LT02 slot, LT05 slot or LT08 slot, these pins can not be used.Table 006-4 LTC0-LTC2 MDF Cross Information (Continued) PINRU NN ING CABLESTATION CABLESLOTSTYPE OF INTERFACE CO (4COT)2-WIRE E&M TIE LINE (2ODT)4-WIRE E&M TIE LINE (2ODT)DID (AUC)DID (4DIT)SLT (8LC)SLT (4LC)SLT (AUC) 42 YL-OR GN 3T0 T0 TxT0 T0 T0 T0 T0 T0 17OR-YLRD R0R0TxR0R0R0R0R0R0 43 YL-GN BK T1 RcvT0 T1 T1 T1 T1 T1 18 GN-YL YL R1 RcvR0 R1 R1 R1 R1 R1 44YL-BRGN T2T1TxT1 T2T2T2 19 BR-YL RD R2 R1 TxR1 R2 R2 R2 45 YL-SL BK T3 RcvT1 T3 T3 T3 20 SL-YL YL R3 RcvR1 R3 R3 R3 46 VI-BL GN Note T0 T0 TxT0 T0 T0 T4 T0 T0 21BL-VI RD R0R0TxR0R0R0R4R0R0 47 VI-OR BK T1 RcvT0 T1 T1 T5 T1 T1 22 OR-VI YL R1 RcvR0 R1 R1 R5 R1 R1 48VI-GNGN T2T1TxT1 T2T6T2 23 GN-VI RD R2 R1 TxR1 R2 R6 R2 49 VI-BR BK T3 RcvT1 T3 T7 T3 24 BR-VI YL R3 RcvR1 R3 R7 R3 50 VI-SL MN* 25 SL-VI MJ*
ND-46551 (E) CHAPTER 3 Page 73 Revision 2.0 NAP-200-006 Sheet 12/54 Termination of Cables on the MDF Note 1:2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON. Note 2:4-wire type for Multiline Terminal/SN610 ATTCON.Table 006-4 LTC0-LTC2 MDF Cross Connection Information (Continued) PINRU NN ING CABLESTATION CABLESLOTSTYPE OF INTERFACE Multiline Te r m i n a l / SN716 DESKCON (8DLC) Note 1Multiline Te r m i n a l / SN716 DESKCON (4DLC) Note 1Multiline Te rm i n a l / SN716 DESKCON (2DLC) Note 1Multiline Ter m in a l (4DLC) Note 2SN610 AT T C O N (2DLC) Note 2EXT. KEY/ EXT. RELAY (DK00)EXT. PAG E / MOH/BGM (4COT) 26 1WH-BL BL-WHGN RD 1T0 R0T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 27 2WH-OR OR-WHBK YLT1 R1T1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 28 3WH-GN GN-WHGN RDT2 R2T2 R2RA1 TA 1RA1 TA 1K5 K4T R 29 4WH-BR BR-WHBK YLT3 R3T3 R3RB1 TB1RB1 TB1K7 K6T R 30 5WH-SL SL-WHGN RDT4 R4RA0 TA 0 31 6RD-BL BL-RDBK YLT5 R5RB0 TB0 32 7RD-OR OR-RDGN RDT6 R6RA1 TA 1 33 8RD-GN GN-RDBK YLT7 R7RB1 TB1 34 9RD-BR BR-RDGN RD 2T0 R0T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 35 10RD-SL SL-RDBK YLT1 R1T1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 36 11BK-BL BL-BKGN RDT2 R2T2 R2RA1 TA 1RA1 TA 1K5 K4T R 37 12BK-OR OR-BKBK YLT3 R3T3 R3RB1 TB1RB1 TB1K7 K6T R 38 13BK-GN GN-BKGN RDT4 R4RA0 TA 0 39 14BK-BR BR-BKBK YLT5 R5RB0 TB0 40 15BK-SL SL-BKGN RDT6 R6RA1 TA 1 41 16YL-BL BL-YLBK YLT7 R7RB1 TB1
CHAPTER 3 ND-46551 (E) Pag e 7 4 Revision 2.0 NAP-200-006 Sheet 13/54 Termination of Cables on the MDF * Major and minor alarm connections are used for external indications. Note 1:When mounting the circuit card with cabling in LT09 slot, these pins must be used. When mounting the circuit card with cabling (except for PN-8LC/PN-8DLC) in LT02 slot, LT05 slot or LT08 slot, these pins can not be used. Note 2: 2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON. Note 3: 4-wire type for Multiline Terminal/SN610 ATTCON. Table 006-4 LTC0-LTC2 MDF Cross Information (Continued) PINRU NN ING CABLESTATION CABLESLOTSTYPE OF INTERFACE Multiline Te r m i n a l / SN716 DESKCON (8DLC) Note 2Multiline Te r m i n a l / SN716 DESKCON (4DLC) Note 2Multiline Te rm i n a l / SN716 DESKCON (2DLC) Note 2Multiline Ter m in a l (4DLC) Note 3SN610 AT T C O N (2DLC) Note 3EXT. KEY/ EXT. RELAY (DK00)EXT. PA G E / M O H / BGM (4COT) 42 YL-OR GN 3T0 R0T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 17 OR-YL RD 43 YL-GN BK T1 R1T1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 18 GN-YL YL 44 YL-BR GN T2 R2T2 R2RA1 TA 1RA1 TA 1K5 K4T R 19 BR-YL RD 45 YL-SL BK T3 R3T3 R3RB1 TB1RB1 TB1K7 K6T R 20 SL-YL YL 46 VI-BL GN Note 1 T4 R4T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 21 BL-VI RD 47 VI-OR BK T5 R5T1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 22 OR-VI YL 48 VI-GN GN T6 R6T2 R2RA1 TA 1RA1 TA 1K5 K4T R 23 GN-VI RD 49 VI-BR BK T7 R7T3 R3RB1 TB1RB1 TB1K7 K6T R 24 BR-VI YL 50 VI-SL MN* 25 SL-VI MJ*
ND-46551 (E) CHAPTER 3 Page 75 Revision 2.0 NAP-200-006 Sheet 14/54 Termination of Cables on the MDF (1) C.O. Trunk (a) 4 Line C.O. Trunk (PN-4COT) Figure 006-6 MDF Cross Connection for a 4Line C.O. Trunk Card (PN-4COT) 29T3294 R3428 T2283 R2327 T12726 T026 2 1 1R0 26T0 2R1 27T1 3R2 28T2 4R3 29T3 (P) 26 T0 1 R0 27 T1 2 R1 28 T2 3 R2 29 T3 4 R3LEN0000 LEN0001 LEN0002 LEN0003 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) LEN0001 (No. 1) LEN0002 (No. 2) LEN0003 (No. 3) TO C.O. L INE TO C.O. L INE TO C.O. L INE TO C.O. L INE PIM0 P PN-4COT LT00LTC0 J
CHAPTER 3 ND-46551 (E) Pag e 7 6 Revision 2.0 NAP-200-006 Sheet 15/54 Termination of Cables on the MDF (2) Tie Line Trunk (a) 4W E&M Trunk (PN-2ODT) Figure 006-7 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) 1 26 2 27 3 28 4 29TxR0 TxT0 RcvR0 RcvT0 TxR1 TxT1 RcvR1 RcvT1MDF LEN0001 (No. 1) LEN0000 (No. 0)PIM0 PN-2ODT LT00 LEN0001 (No. 1) 1 26 2 27 3 28 4 29 (Rcv Tip) (Rcv Ring) (M) TO TIE LINE JPLTC0 LEN0000 (No. 0) 08 07 06 05 04 M1 03 E1 02 M0 01 E0(E) (Tx Tip) (Tx Ring) JCN1 INSTALLATION CABLE Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card. Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT card.
ND-46551 (E) CHAPTER 3 Page 77 Revision 2.0 NAP-200-006 Sheet 16/54 Termination of Cables on the MDF Figure 006-7 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (Continued) M1 E1 M0 E0LEN0001 LEN0000 CN1 1 LTC CONNECTOR2 CN1 CONNECTOR (FRONT CONNECTOR) LEN0000 LEN00011 TxR0 26 TxT0 2 RcvR0 27 RcvT0 3 TxR1 28 TxT1 4 RcvR1 29 RcvT1 (P) 26 TxT0 1 TxR0 27 RcvT0 2 RcvR0 28 TxT1 3 TxR1 29 RcvT1 4 RcvR1 LTC0 (J)
CHAPTER 3 ND-46551 (E) Pag e 7 8 Revision 2.0 NAP-200-006 Sheet 17/54 Termination of Cables on the MDF (b) 2W E&M (PN-2ODT) Figure 006-8 MDF Cross Connection for a 2W E&M Trunk Card (PN-2ODT) 1 26 2 27 3 28 4 29 TO-10 TO-9 R0 T0 R1 T1 R2 T2 R3 T3MDF LEN0001 (No. 1) LEN0000 (No. 0)PIM0 PN-2ODT LT00 LEN0001 (No. 1) 1 26 2 27 3 28 4 29 (M) TO TIE LINE JPLTC0 LEN0000 (No. 0) CN1 08 07 06 05 04 M1 03 E1 02 M0 01 E0(E) (Ring) (Tip) J INSTALLATION CABLE Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card. Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT card.