ND-46551 (E) CHAPTER 3 Page 79 Revision 2.0 NAP-200-006 Sheet 18/54 Termination of Cables on the MDF Figure 006-8 MDF Cross Connection for a 2W E&M Trunk Card (PN-2ODT) (Continued) M1 E1 M0 E0LEN0001 LEN0000 CN1 1 LTC CONNECTOR2 CN1 CONNECTOR (FRONT CONNECTOR) LEN0000 LEN00011R026T0 227 3R228T2 429 (P) 26 T0 1 R0 27 2 28 T2 3 R2 29 4 LTC0 (J)
CHAPTER 3 ND-46551 (E) Pag e 8 0 Revision 2.0 NAP-200-006 Sheet 19/54 Termination of Cables on the MDF (3) DID Trunk (a) 2 Line DID Trunk (PN-AUCA) Figure 006-9 MDF Cross Connection for a 2 Line DID Trunk Card (PN-AUCA) 29294 428 283 327 2726 26 2 1 LEN0000 LEN0001MDF 1 2 PIM0 P PN-AUCA LT00LTC0 J T1 R1 T0 R0 LEN0000 (No. 0) LEN0001 (No. 1) TO DID LINE 1R026T0 2R127T1 328 429 (P) 26 T0 1 R0 27 T1 2 R1 28 3 29 4 LTC0 (J) TO DID LINE Note :The PN-AUCA card can also be used as a long line circuit with the Power Failure Transfer (PFT) function.
ND-46551 (E) CHAPTER 3 Page 81 Revision 2.0 NAP-200-006 Sheet 20/54 Termination of Cables on the MDF (b) 4 Line DID Trunk (PN-4DITB) Figure 006-10 MDF Cross Connection for a 4 Line DID Trunk Card (PN-4DITB) 29T3294 R3428 T2283 R2327 T12726 T026 2 1 1R026T0 2R127T1 3R228T2 4R329T3 (P) 26 T0 1 R0 27 T1 2 R1 28 T2 3 R2 29 T3 4 R3LEN0000 LEN0001 LEN0002 LEN0003 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) LEN0001 (No. 1) LEN0002 (No. 2) LEN0003 (No. 3) TO DID LINE TO DID LINE TO DID LINE TO DID LINE PIM0 P PN-4DITB LT00LTC0 J
CHAPTER 3 ND-46551 (E) Pag e 8 2 Revision 2.0 NAP-200-006 Sheet 21/54 Termination of Cables on the MDF (4) Single Line Telephone (a) Standard Line (PN-8LC) Figure 006-11 MDF Cross Connection for a Single Line Telephone (Standard Line) 33T7338 R7832 T6327 R6727 T12726 T026 2 1 1R026T0 2R127T1 7R632T6 8R733T7 (P) 26 T0 1 R0 27 T1 2 R1 32 T6 7 R6 33 T7 8 R7LEN0000 LEN0001 LEN0006 LEN0007 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) PIM0 P PN-8LC LT00LTC0 J LEN0001 (No. 1) LEN0006 (No. 6) LEN0007 (No. 7) TO SINGLE LINE TELEPHONE Note :The same connection is required when using PN-4LC. • • •• • •• • •• • • • • •• • •• • •• • •• • •• • •• • •• • • • • •
ND-46551 (E) CHAPTER 3 Page 83 Revision 2.0 NAP-200-006 Sheet 22/54 Termination of Cables on the MDF (b) Long Line (PN-AUCA) Figure 006-12 MDF Cross Connection for a Single Line Telephone (Long Line) 29294 428 283 327 2726 26 2 1 LEN0000 LEN0001MDF 1 2 PIM0 P PN-AUCA LT00LTC0 J T1 R1 T0 R0 LEN0000 (No. 0) LEN0001 (No. 1) TO SINGLE LINE TELEPHONE (FOR LONG LINE) 1R026T0 2R127T1 328 429 (P) 26 T0 1 R0 27 T1 2 R1 28 3 29 4 LTC0 (J) Note 1:The PN-AUCA card can also be used as a DID Trunk card. Note 2:For the cross connection for the Power Failure Transfer (PFT), see item (12) in this NAP. TO SINGLE LINE TELEPHONE (FOR LONG LINE)
CHAPTER 3 ND-46551 (E) Pag e 8 4 Revision 2.0 NAP-200-006 Sheet 23/54 Termination of Cables on the MDF (5) Multiline Terminal/DSS Console (a) Standard Line (PN-8DLCJ/8DLCP) Figure 006-13 MDF Cross Connection for a Multiline Terminal/DSS Console (Standard Line) MODULAR TERMINAL TO MULTILINE TERMINAL / DSS CONSOLE 33T7338 R7832 T6327 R6727 T12726 T026 2 1 MDF R01 R12 LEN0000 (No. 0) PIM0 P PN-8DLC LT00LTC0 J LEN0001 (No. 1) LEN0006 (No. 6) LEN0007 (No. 7) • • •• • •• • •• • • 1R026T0 2R127T1 7R632T6 8R733T7 (P) 26 T0 1 R0 27 T1 2 R1 32 T6 7 R6 33 T7 8 R7LEN0000 LEN0001 LEN0006 LEN0007 LTC0 (J) • • •• • •• • •• • •• • •• • •• • •• • • • • • Note :The same connection is required when using PN-4DLCD/4DLCQ.
ND-46551 (E) CHAPTER 3 Page 85 Revision 2.0 NAP-200-006 Sheet 24/54 Termination of Cables on the MDF (b) Long Line (PN-2DLCB) Figure 006-14 MDF Cross Connection for a Multiline Terminal/DSS Console (Long Line) 29294 428 283 327 2726 26 2 1 1R029T0 2R128T1 327 426 (P) 26 T0 1 R0 27 T1 2 R1 28 3 29 4LEN0000 LEN0001 LTC0 (J)MDF 1 2 MODULAR TERMINAL PIM0 P PN-2DLCB LT00LTC0 J T1 T0 R0 R1 LEN0000 (No. 0) LEN0001 (No. 1) TO MULTILINE TERMINAL / DSS CONSOLE
CHAPTER 3 ND -4 6551 ( E) NAP-2 00-0 06 S cre w th e h and se t sup po rt on to the bo ttom o f the consol e a s sh ow n in F igu re 00 6-15 . HAN DSET
ND-46551 (E) CHAPTER 3 Page 87 Revision 2.0 NAP-200-006 Sheet 26/54 Termination of Cables on the MDF STEP 2:To provide the console with the headset in place of the handset, unplug the modular cord from the hand- set and then plug the modular cord to the Jack Set. Figure 006-16 Jack Set Installation for SN610 ATTCON SN610 ATTCON MODULAR CORD JACK SET
CHAPTER 3 ND -4 6551 ( E) NAP-2 00-0 06 S et th e s wit ch lo cate d insid e th e c o nsol e a cc ording t o the type o f h ea d se t/h ands et conn ec te d . R ef er to • Slid e the di rec tory o ut o f th e w ay. A CCESS PANEL