NEC Neax2000 Ivs Small Platform System Manual
Have a look at the manual NEC Neax2000 Ivs Small Platform System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ND-46551 (E) ISSUE 2 STOCK # 151953 Small Platform System Manual SEPTEMBER, 1998 NEC America, Inc. ®
LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its em- ployees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. NEAX and D term are registered trademarks of NEC Corporation. Copyright 1998 NEC America, Inc. Printed in USA
ND-46551 (E) ISSUE 2 SEPTEMBER, 1998 NEAX2000 IVS Small Platform System Manual TABLE OF CONTENTS Page LIST OF FIGURES.......................................................................................................................................... iv LIST OF TABLES............................................................................................................................................ vi REGULATORY INFORMATION ........................................................................................................vii ND-46551 (E) TABLE OF CONTENTS Pag e i Revision 2.0 1. Regulatory Requirements ........................................................................................................................ vii 2. FCC Part 15 Requirements...................................................................................................................... vii 3. FCC Part 68 Registration ......................................................................................................................... vii 3.1 Company Notification ............................................................................................................................... vii 3.2 Service Requirements.............................................................................................................................. viii 3.3 Location of FCC Compliance Labels ....................................................................................................... viii 4. Direct-Inward Dialing (DID) Calls ............................................................................................................. viii 5. Regulatory Information on Single-Line Analog Telephones..................................................................... ix 6. Hearing Aid Compatibility......................................................................................................................... ix 7. Industry Canada CS-03 ........................................................................................................................... ix 8. Safety Certifications ................................................................................................................................. x 8.1 Safety Considerations .............................................................................................................................. x CHAPTER 1 INTRODUCTION ................................................................................................................. 1 1. PURPOSE ............................................................................................................................................... 1 2. REFERENCE MANUAL ........................................................................................................................... 1 3. HOW TO FOLLOW THIS MANUAL ......................................................................................................... 2 4. SCOPE OF INSTALLATION PROCEDURES ......................................................................................... 2 CHAPTER 2 GENERAL INFORMATION ................................................................................................. 3 1. TRUNKING DIAGRAM ............................................................................................................................ 3 2. SYSTEM CONFIGURATIONS................................................................................................................. 5 3. FUNCTIONAL OUTLINE OF EQUIPMENT ............................................................................................. 9 3.1 Functional Outline of Modules ................................................................................................................. 9 3.2 Functional Outline of Installation Hardware ............................................................................................. 10 3.3 Functional Outline of Circuit Cards .......................................................................................................... 10 3.3.1 Control Circuit Card ...................................................................................................................... 10 3.3.2 Application Circuit Cards............................................................................................................... 11 3.3.3 Line/Trunk Circuit Cards ............................................................................................................... 12 4. CIRCUIT CARD INSTALLATION CONDITIONS ..................................................................................... 16 4.1 Circuit Card Mounting Slots ..................................................................................................................... 16 4.2 Installation Conditions .............................................................................................................................. 17
TABLE OF CONTENTS ND-46551 (E) Pag e ii Revision 2.0 TABLE OF CONTENTS (CONTINUED) Page CHAPTER 3 INSTALLATION PROCEDURE ........................................................................................... 19 1. PRECAUTIONS ....................................................................................................................................... 19 1.1 Grounding Requirements ......................................................................................................................... 19 1.2 Static Electricity Guard............................................................................................................................. 20 1.3 Removing/Inserting Circuit Cards ............................................................................................................ 22 2. PROCEDURE .......................................................................................................................................... 24 NAP-200 -001 Unpacking ...................................................................................................................... 26 1. Unpacking Procedure..................................................................................................... 26 -002 Marking and Drilling........................................................................................................28 1. Confirmation of the Equipment Layout ........................................................................... 28 2. Marking........................................................................................................................... 28 2.1 Floor Standing ................................................................................................................ 28 2.2 Wall-Mounting ................................................................................................................29 3. Drilling ............................................................................................................................ 30 -003 Installation of Main Equipment ....................................................................................... 31 1. Floor Standing Installation .............................................................................................. 31 2. Wall-Mounting Installation .............................................................................................. 34 3. 19-Inch Rack-Mounting Installation ................................................................................ 39 4. Desk Top Installation ...................................................................................................... 41 5. AC Power Cabling .......................................................................................................... 43 6. MDFM/BATTM Installation ............................................................................................. 48 -004 Connection of Battery ..................................................................................................... 52 1. Battery Connection ......................................................................................................... 52 1.1 Internal Battery Connection ............................................................................................ 54 1.2 Battery Connection in the BATTM .................................................................................. 56 -005 Cable Running to the MDF ............................................................................................. 57 1. MDF Cable .....................................................................................................................57 2. Installation of External MDF ........................................................................................... 58 3. Cable Running to the External MDF............................................................................... 59 4. Cable Running to the MDFM .......................................................................................... 60 -006 Termination of Cables on the MDF ................................................................................ 62 1. Cable Connection to the MDF ........................................................................................ 62 2. MDF Cross Connections ................................................................................................ 66 -007 Installation of SN716 DESKCON ................................................................................... 116 1. SN716 - DESKCON ....................................................................................................... 116 -008 Switch Setting of Circuit Card......................................................................................... 127 1. Circuit Cards Switch Setting ........................................................................................... 127 2. PN-CP03 (MP) ............................................................................................................... 128 3. PZ-PW86 (PWR) ............................................................................................................ 131 4. PZ-PW86(D) (PWR) ....................................................................................................... 134 5. PN-PW00 (EXTPWR)..................................................................................................... 136 6. PN-8DLCJ/8dlcp (DLC) .................................................................................................. 138 7. PN-8LCS (LC) ................................................................................................................ 139 -009 Mounting of Circuit Cards ............................................................................................... 140 1. Mounting Procedure ....................................................................................................... 140 -010 System Initialization and System Data Entry.................................................................. 143 1. System Initialization........................................................................................................143 1.1 All Clear, Except LEN0000 CAT..................................................................................... 143 1.2 Resident System Program ............................................................................................. 143
ND-46551 (E) TABLE OF CONTENTS Page iii Revision 2.0 TABLE OF CONTENTS (CONTINUED) Page 2. System Data Entry ......................................................................................................... 144 2.1 CAT ................................................................................................................................ 144 2.2 MAT ................................................................................................................................ 145 2.3 Feature Programming .................................................................................................... 145 -011 Operation Test................................................................................................................ 150 1. Operation Test................................................................................................................ 150 -012 Cleaning and Visual Check ............................................................................................ 151 1. Cleaning ......................................................................................................................... 151 2. Visual Check .................................................................................................................. 151 -013 Mounting of the Front Cover........................................................................................... 152 1. Mounting of the Front Cover........................................................................................... 152 CHAPTER 4 OFFICE DATA PROGRAMMING........................................................................................ 153 1. CUSTOMIZING DATA ............................................................................................................................. 153 1.1 Data Programming Procedure ................................................................................................................. 153 1.2 General Information on Customizing Data ............................................................................................... 153 1.2.1 Numbering Plan ............................................................................................................................ 153 1.2.2 Station Data .................................................................................................................................. 154 1.2.3 Trunk Data .................................................................................................................................... 154 1.2.4 Station Hunting Group Data .......................................................................................................... 155 1.2.5 Call Pickup Group Data ................................................................................................................ 155 1.2.6 Speed Calling-System Data .......................................................................................................... 156 1.2.7 Port Assignment Table.................................................................................................................. 156 1.3 Customer Specification Sheets ................................................................................................................ 161 1.3.1 Numbering Plan ............................................................................................................................ 161 1.3.2 Station Data .................................................................................................................................. 162 1.3.3 Trunk Data .................................................................................................................................... 163 1.3.4 Station Hunting Group Data .......................................................................................................... 164 1.3.5 Call Pickup Group Data ................................................................................................................ 165 1.3.6 Speed Calling-System Data .......................................................................................................... 166 1.4 System Configuration............................................................................................................................... 167 1.4.1 Port Assignment Table.................................................................................................................. 167 1.4.2 Bay Face Layout for Module ......................................................................................................... 168 1.4.3 Quantity Table for Circuit Cards.................................................................................................... 169
LIST OF FIGURES ND-46551 (E) Pag e iv Revision 2.0 LIST OF FIGURES Figure TitlePage 1-1 Reference Manuals for Installation ..................................................................................................... 1 1-2 Scope of Installation Procedures ........................................................................................................ 2 2-1 PBX Trunking Diagram ....................................................................................................................... 3 2-2 Floor Standing Installation .................................................................................................................. 5 2-3 Wall-Mounting Installation................................................................................................................... 6 2-4 19-Inch Rack-Mounting Installation .................................................................................................... 7 2-5 Desk Top Installation .......................................................................................................................... 8 2-6 Circuit Card Mounting Slots ................................................................................................................ 16 3-1 Static Electricity Guard ....................................................................................................................... 20 3-2 Procedure Flowchart........................................................................................................................... 24 001-1 Unpacking of Main Equipment ............................................................................................................ 27 002-1 Floor Marking for Main Equipment...................................................................................................... 28 002-2 Wall Mounting Points .......................................................................................................................... 29 002-3 Instruction for Anchor Bolt .................................................................................................................. 30 003-1 Securing of the BASE ......................................................................................................................... 31 003-2 Mounting of the PIM............................................................................................................................ 32 003-3 Mounting of the TOP COVER ............................................................................................................. 33 003-4 Screwing the RACK PARTS to a Wall ................................................................................................ 35 003-5 Mounting the PIM to the RACK PARTS .............................................................................................. 36 003-6 Screwing the PIM to the RACK PARTS .............................................................................................. 37 003-7 Connecting the Covers and AC CORD to the PIM ............................................................................. 38 003-8 Connecting the Covers and AC CORD to the PIM ............................................................................. 39 003-9 Mounting the PIM to the 19-Inch Rack ............................................................................................... 40 003-10 Connecting the Covers and AC CORD to the PIM .............................................................................41 003-11 Connecting the RUBBER FOOT to the PIM ....................................................................................... 42 003-12 Cable Connection on the PZ-PW86.................................................................................................... 43 003-13 Cable Connection between the PZ-PW86 and the BWB .................................................................... 45 003-14 AC Power Cable Wiring ...................................................................................................................... 46 003-15 Screwing the AC CORD-B to the Terminals ....................................................................................... 47 003-16 Connection of RACK PARTS and BASE ............................................................................................ 48 003-17 Connection of RACK PARTS.............................................................................................................. 49 003-18 Connection of the PIM and the RACK PARTS ................................................................................... 50 003-19 Connection of PIM and MDFM/BATTM .............................................................................................. 51 004-1 Internal Battery Mounting.................................................................................................................... 54 004-2 Internal Battery Connection ................................................................................................................ 55 004-3 Battery Mounting into the BATTM....................................................................................................... 56 005-1 MDF Cable.......................................................................................................................................... 57 005-2 Cable Hole Location ........................................................................................................................... 58 005-3 Cable Running to External MDF ......................................................................................................... 59 005-4 Cable Running to MDFM .................................................................................................................... 60 005-5 MDF Cable Connection to MDFM Example........................................................................................ 61 006-1 Card Slots and LTC Connectors Location (PIM0) ..............................................................................62 006-2 Card Slots and LTC Connectors Location (PIM1) ..............................................................................63 006-3 Location of Each LEN ......................................................................................................................... 64 006-4 LTC Connector Pin Arrangement (PIM0) ............................................................................................ 65 006-5 LTC Connector Pin Arrangement (PIM1) ............................................................................................ 70 006-6 MDF Cross Connection for a 4Line C.O. Trunk Card (PN-4COT) ...................................................... 75 006-7 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) ......................................................... 76 006-8 MDF Cross Connection for a 2W E&M Trunk Card (PN-2ODT) ......................................................... 78 006-9 MDF Cross Connection for a 2 Line DID Trunk Card (PN-AUCA)...................................................... 80
ND-46551 (E) LIST OF FIGURES Pag e v Revision 2.0 LIST OF FIGURES (CONTINUED) Figure TitlePage 006-10 MDF Cross Connection for a 4 Line DID Trunk Card (PN-4DITB) ..................................................... 81 006-11 MDF Cross Connection for a Single Line Telephone (Standard Line) ................................................ 82 006-12 MDF Cross Connection for a Single Line Telephone (Long Line) ...................................................... 83 006-13 MDF Cross Connection for a Multiline Terminal/DSS Console (Standard Line) ................................. 84 006-14 MDF Cross Connection for a Multiline Terminal/DSS Console (Long Line) ....................................... 85 006-15 Mounting Handset Support to SN610 ATTCON .................................................................................86 006-16 Jack Set Installation for SN610 ATTCON ........................................................................................... 87 006-17 SN610 ATTCON Switch Setting ......................................................................................................... 88 006-18 Cable Connection to SN610 ATTCON ............................................................................................... 90 006-19 MDF Cross Connection for SN610 ATTCON .....................................................................................91 006-20 MDF Cross Connection for Day/Night Mode Change by External Key ............................................... 92 006-21 External TAS Indicator Connection Outline ........................................................................................ 93 006-22 MDF Cross Connection for a TAS Indicator with a Battery................................................................. 94 006-23 MDF Cross Connection for a TAS Indicator with a Battery (Ground Start) ......................................... 95 006-24 Paging Equipment Connection Outline ............................................................................................... 96 006-25 MDF Cross Connection for Paging Equipment ................................................................................... 97 006-26 External Tone Source Connection Outline ......................................................................................... 100 006-27 MDF Cross Connection for an External Tone Source Equipment ...................................................... 101 006-28 Connecting a Tone Source Supplied with D.C. .................................................................................. 103 006-29 MDF Cross Connection for External BGM Sources ............................................................................104 006-30 Cable Connection Between PN-TNTA and External BGM Sources ................................................... 105 006-31 PFT Connection Outline ..................................................................................................................... 106 006-32 MDF Cross Connection for the PFT (PN-AUCA) ................................................................................ 107 006-33 PFT (PZ-8PFTA) Connection Outline ................................................................................................. 109 006-34 Connection of 25-Pair Cable and PZ-8PFTA...................................................................................... 110 006-35 Mounting PZ-8PFTA Card to the PIM ................................................................................................. 111 006-36 PFT Connector Pin Assignment ......................................................................................................... 112 006-37 MDF Cross Connection for the PFT (PZ-8PFTA) ............................................................................... 113 006-38 MDF Cross Connection for an Alarm Display Panel ........................................................................... 115 007-1 Assembly of SN716 DESKCON ......................................................................................................... 116 007-2 SN716 DESKCON Cable Connection ................................................................................................ 117 007-3 MDF Cross Connection With AC Adapter Power Option .................................................................... 118 007-4 MDF Cross Connection via PN-PW00 Power Option ......................................................................... 119 007-5 Mounting of Handset Support to SN716 DESKCON .......................................................................... 120 007-6 Headset Installation for SN716 DESKCON ........................................................................................ 121 007-7 Cable Connection to SN716 DESKCON ............................................................................................ 122 007-8 AC-DC ADAPTER Connection to SN716 DESKCON ........................................................................ 123 007-9 Mounting PW00 Card into PIM ........................................................................................................... 124 007-10 PW00 Card Connection to SN716 DESKCON ................................................................................... 125 007-11 MDF Cross Connection for SN716 DESKCON .................................................................................. 126 008-1 PN-CP03 (MP) Card ........................................................................................................................... 128 008-2 PZ-PW86 (PWR) Card........................................................................................................................ 131 008-3 PZ-PW86(D) (PWR) Card................................................................................................................... 134 008-4 PN-PW00 (EXTPWR) Card ................................................................................................................ 136 008-5 PN-8DLCJ/8DLCP (DLC) Card........................................................................................................... 138 008-6 PN-8LCS (LC) Card ............................................................................................................................ 139 009-1 PZ-PW86(C) Card Lamp Indication .................................................................................................... 140 009-2 Mounting Circuit Cards ....................................................................................................................... 141 009-3 Installing Card Stopper ....................................................................................................................... 142 013-1 Mounting of the Front Cover ............................................................................................................... 152 4-1 Module Configuration (Floor Standing) ............................................................................................... 168
LIST OF TABLESND-46551 (E) Pag e v i Revision 2.0 LIST OF TABLES Table TitlePage 2-1 Symbols in Trunking Diagram Description.......................................................................................... 4 2-2 Functional Outline of Modules ............................................................................................................ 9 2-3 Functional Outline of Installation Hardware ........................................................................................ 10 2-4 Functional Outline of Control Circuit Cards ........................................................................................ 10 2-5 Functional Outline of Application Circuit Cards .................................................................................. 11 2-6 Functional Outline of Line/Trunk Circuit Cards ................................................................................... 12 2-7 Line Condition of Each Terminals ....................................................................................................... 14 3-1 Removing/Inserting Circuit Cards Procedure ..................................................................................... 22 003-1 Recommended Fasteners .................................................................................................................. 34 006-1 LTC Connector Accommodation......................................................................................................... 62 006-2 LTC Connector Accommodation......................................................................................................... 63 006-3 LTC0-LTC2 MDF Cross Connection Information................................................................................66 006-4 LTC0-LTC2 MDF Cross Connection Information................................................................................71 008-1 Control Circuit Cards .......................................................................................................................... 127 008-2 Line/Trunk Circuit Cards ..................................................................................................................... 127 008-3 PN-CP03 (MP) Card Lamp Indications ............................................................................................... 128 008-4 PN-CP03 (MP) Card Switch Settings ................................................................................................. 129 008-5 PZ-PW86(C) (PWR) Card Lamp Indications ...................................................................................... 132 008-6 PZ-PW86(C) (PWR) Card Switch Settings ......................................................................................... 133 008-7 PZ-PW86(D) (PWR) Card Lamp Indications ...................................................................................... 134 008-8 PZ-PW86(D) (PWR) Card Switch Settings ......................................................................................... 135 008-9 PN-PW00 (EXTPWR) Card Lamp Indications ....................................................................................136 008-10 PN-PW00 (EXTPWR) Card Switch Settings ....................................................................................... 137 008-11 PN-8DLCJ8DLCP (DLC) Card Lamp Indications .............................................................................. 138 008-12 PN-8LCS (LC) Card Lamp Indications................................................................................................ 139 4-1 Data Programming Procedure ............................................................................................................ 153 4-2 Port Assignment Method .................................................................................................................... 156 4-3 Numbering Plan Data Table ............................................................................................................... 161 4-4 Station Data Table .............................................................................................................................. 162 4-5 Trunk Data Table ................................................................................................................................ 163 4-6 Station Hunting Group Data Table...................................................................................................... 164 4-7 Call Pickup Group Data Table ............................................................................................................ 165 4-8 Speed Calling-System Data Table...................................................................................................... 166 4-9 Port Assignment Table ....................................................................................................................... 167 4-10 Quantity Table for Module .................................................................................................................. 168 4-11 Quantity Table for Line/Trunk Circuit Cards ....................................................................................... 169 4-12 Quantity Table for Control Circuit Cards ............................................................................................. 169 4-13 Quantity Table for Application Circuit Cards ....................................................................................... 170
ND-46551 (E) REGULATORY INFORMATION Page vii Revision 2.0 REGULATORY INFORMATION 1. Regulatory Requirements The Federal Communications Commission (FCC) has established rules that permit the NEAX2000 IVS to be direct- ly connected to the telephone network. A jack is provided on party lines or coin lines. The telephone company may make changes in its technical operations and procedures. If such changes affect the compatibility or use of the NEAX2000 IVS, the telephone company must provide adequate notice of the changes. This equipment complies with the requirements in Part 15 of FCC Rules for a Class A computing device. Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct this interference. 2. FCC Part 15 Requirements In compliance with FCC Part 15 Rules, the following statement is provided: 3. FCC Part 68 Registration 3.1 Company Notification Before installing the NEAX2000 IVS to the telephone network, the telephone company must be provided with the following: • Your telephone number • The FCC registration numbers: The Ringer Equivalence Number is 1.6B; the required USOC jacks are RJ21X, RJ2EX, and RJ2GX. JA PAN USA PBX AY5JPN-20542-PF-E AY5USA-21582-PF-E Hybrid AY5JPN-20543-MF-E AY5USA-21583-MF-E Key system AY5JPN-20586-KF-E AY5USA-21584-KF-E WARNING This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause in- terference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interfer- ence when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to cor- rect the interference.
REGULATORY INFORMATION ND-46551 (E) Pag e v iii Revision 2.0 Note :Limitations on features exist if the system is registered as a KF system. Refer to Features and Specifications for details. 3.2 Service Requirements In the event of equipment malfunction, all repairs will be performed by NEC or an authorized distributor of NEC. It is the responsibility of users requiring service to report the need for service to NEC or to one of their authorized distributors. If the equipment causes harm to the telephone network, the telephone company will notify you in advance that tem- porary discontinuance of service may be required. If advance notice is not practical, the telephone company will no- tify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that affect the op- eration of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact NEC America, Inc.’s Oregon plant at (503) 648-5000 for repair and/or warranty information. If the trouble is causing harm to the telephone network, the telephone com- pany may request that you remove the equipment from the network until the problem is resolved. NO REPAIRS CAN BE DONE BY THE CUSTOMER. 3.3 Location of FCC Compliance Labels Labels stating the NEAX2000 IVS FCC registration number and compliance with FCC Parts 15 and 68 are attached to the Base Unit. If the unit is in a table-top configuration, the labels are located on the side of the enclosure. Example of the labels are as follows: 4. Direct-Inward Dialing (DID) Calls Allowing this equipment to be operated in such a manner as to not provide for proper answer supervision is a viola- tion of Part 68 of the FCC’s rules. PROPER ANSWER SUPERVISION IS WHEN: (a) This equipment returns answer supervision to the PSTN when DID calls are: • Answered by the called station • Answered by the attendant • Routed to a recorded announcement that can be administered by the CPE user • Routed to a dial prompt “This equipment complies with the requirements in Part 15 of FCC Rules for a Class A computing device. Operation of this equipment in a residential area may cause unacceptable interference to radio and TV re- ception requiring the operator to take whatever steps are necessary to correct the interference.”NEAX2000 IVS Complies With Part 68 FCC Rules FCC Registration Numbers : AY5USA-21582-PF-E AY5USA-21583-MF-E AY5USA-21584-KF-E Ringer Equivalence : 1.6B NEC America, Inc. MADE IN USA