ND-46551 (E) CHAPTER 3 Page 129 Revision 2.0 NAP-200-008 Sheet 3/13 Switch Setting of Circuit Card (3) Switch Setting Table 008-4 PN-CP03 (MP) Card Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW3 (Rotary SW) 0 - FOn Line (Call processing is in progress) 2Off Line (Call processing is stopped) • I/O port : Depending on CM40 YY=08 3Off Line (Call processing is stopped) • I/O port : 1200bps (Fixed) B For clearing the office data C For setting the resident system program 1, 4 - 9 A, D - FNot used SW1 (Push SW) For initializing the CPU SW2 (Piano Key SW) 1ON KF Mode MF/PF Mode 2, 3Selection of PLO (Phase Locked Oscillator) • When using the internal PLO of MP card: 0 ON OFF 4 3 2 1 OFF SWITCH OFF ON1.5MHz clock [For PN-24DTA/PN-24DTA-A] 192kHz clock [For PN-BRTA] 2MHz clock [For PN-30DTC] Not used OFF OFF ON OFF ON ON FUNCTION 23 NUMBER
CHAPTER 3 ND-46551 (E) Pag e 1 30 Revision 2.0 NAP-200-008 Sheet 4/13 Switch Setting of Circuit Card The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note :Set the groove on the switch knob to the desired switch position. Table 008-4 PN-CP03 (MP) Card Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW2 (Piano Key SW) 2, 3 • When using the PLO card (PN-CK00): SW2-2 SW2-3 OFF ON • When not using the internal PLO and the PLO card: SW2-2 SW2-3 OFF OFF 4 ONWhen using RS1 port for built-in MODEM. OFF When using RS1 port for RS-232C. VR (Rotary SW) Variable Resistor for External Hold Tone Source (0 - 20 KW : Clockwise) JP0 (Jumper pin) For normal operation DOWN Not used JP1 (Jumper pin) For normal operation DOWN For using External Tone SourceON OFF 4 3 2 1 20 0 Front UP Front UP
ND-46551 (E) CHAPTER 3 Page 131 Revision 2.0 NAP-200-008 Sheet 5/13 Switch Setting of Circuit Card CAUTION:When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. 3. PZ-PW86 (PWR) (1) Locations of Lamps, Switches, and Connectors Figure 008-2 PZ-PW86 (PWR) Card FRONT VIEW BATT2MN MJ ONBATTERY SIDE VIEW GND –27V FG OFFON 240VAC 100/120VAC 2ON 2 1 ON SW301 START SIG 1 SW1 BATT1 AC INPUTMODE SW102
CHAPTER 3 ND-46551 (E) Pag e 1 32 Revision 2.0 NAP-200-008 Sheet 6/13 Switch Setting of Circuit Card (2) Lamp Indications Table 008-5 PZ-PW86(C) (PWR) Card Lamp Indications LAMP NAME COLOR FUNCTION MJ Red Lights upon occurrence of a major fault. MN Orange Lights upon occurrence of a minor fault. ON Green Remains lit while the power is on.
ND-46551 (E) CHAPTER 3 Page 133 Revision 2.0 NAP-200-008 Sheet 7/13 Switch Setting of Circuit Card (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Table 008-6 PZ-PW86(C) (PWR) Card Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW101 (Piano Key SW) 1 Always set to OFF 2Float charging for sealed batteries (Nor- mal Setting). OPTION: Periodic equalize charging of external vented batteries. (set to equalize for Gel cell or no battery). OFF Float charging, for vented batteries only. SW For turning AC power and the battery on OFFFor turning AC power and the battery off SW102 BATTERY START PRESS MO- MENTARILYTo start each PIM on battery power, when AC power is not provided (switch “SW” must be ON) AC INPUT: 90 V - 138 V DOWN AC INPUT: 180 V - 264 V SW301 1ON CR Voltage: 75 Vrms OFF CR Voltage: 90 Vrms 2ON Frequency: 20 Hz OFF Frequency: 25 Hz 1 2 ON OFF ON ON (–) OFF (O) ON 240 VAC 100/120 VAC UP 2 1ONOFF 20Hz 25Hz 75V 90V
CHAPTER 3 ND-46551 (E) Pag e 1 34 Revision 2.0 NAP-200-008 Sheet 8/13 Switch Setting of Circuit Card 4. PZ-PW86(D) (PWR) (4) Locations of Lamps, Switches and Connectors Figure 008-3 PZ-PW86(D) (PWR) Card (2) Lamp Indications Table 008-7 PZ-PW86(D) (PWR) Card Lamp Indications LAMP NAME COLOR FUNCTION MJ Red Lights upon occurrence of a major trouble MN Orange Lights upon occurrence of a minor trouble ON Green Remains lit while the operating power is being supplied FRONT VIEWBATT2 MN MJ ON BATTERY SIDE VIEW GND –27V FG OFFON 240VAC 100/120VAC2ON 2 1 ON SW102 START SIG 1 SW1 BATT1 AC INPUTMODE SW301 (CN103) SIG (CN103)
ND-46551 (E) CHAPTER 3 Page 135 Revision 2.0 NAP-200-008 Sheet 9/13 Switch Setting of Circuit Card (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Table 008-8 PZ-PW86(D) (PWR) Card Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK MODE 1Always set to OFF 2Float charging, for sealed batteries (Normal Setting). OPTION: Periodic Equalize charging of external vented batteries. OFFFloat charging, for vented batteries only. SW1 For turning AC power and the battery on OFFFor turning AC power and the battery off AC INPUT: 90 V - 138 V DOWN AC INPUT: 180 V - 264 V SW102 PRESS MO- MENTARILYTo start each PIM on battery power, when AC power is not provided (switch “SW” must be ON) SW301 1ON CR Voltage: 75 Vrms CR Voltage: 90 Vrms 2Frequency: 20 Hz OFF Frequency: 25 Hz ON 1 2 OFF ON OFF (O) ON (I) ON 240 VAC 100/120 VAC UP 25Hz 1 2 OFF 90V 20Hz ON 75V OFF ON
CHAPTER 3 ND-46551 (E) Pag e 1 36 Revision 2.0 NAP-200-008 Sheet 10/13 Switch Setting of Circuit Card 5. PN-PW00 (EXTPWR) (4) Locations of Lamps, Switches and Connectors Figure 008-4 PN-PW00 (EXTPWR) Card (2) Lamp Indications Table 008-9 PN-PW00 (EXTPWR) Card Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Remains lit while –48 V power is being supplied RUN MB CONN
ND-46551 (E) CHAPTER 3 Page 137 Revision 2.0 NAP-200-008 Sheet 11/13 Switch Setting of Circuit Card The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note :When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.Table 008-10 PN-PW00 (EXTPWR) Card Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK MB (Toggle SW) Note UP For make-busy (–48 V power off) For normal operation (–48 V power on) ON DOWN
CHAPTER 3 ND-46551 (E) Pag e 1 38 Revision 2.0 NAP-200-008 Sheet 12/13 Switch Setting of Circuit Card 6. PN-8DLCJ/8DLCP (DLC) (1) Locations of Lamps, Switches and Connectors Figure 008-5 PN-8DLCJ/8DLCP (DLC) Card (2) Lamp Indications • Switch Settings This card has no switches. Table 008-11 PN-8DLCJ8DLCP (DLC) Card Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 7 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the sys- tem data for this card is not assigned. BL7 BL4BL6 BL5 BL3 BL2 BL0 BL1