Home > NEC > Communications System > NEC Neax2000 Ivs Small Platform System Manual

NEC Neax2000 Ivs Small Platform System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax2000 Ivs Small Platform System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-46551 (E) CHAPTER 3
    Page 129
    Revision 2.0
    NAP-200-008
    Sheet 3/13
    Switch Setting of Circuit Card
    (3) Switch Setting
    Table 008-4  PN-CP03 (MP) Card Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW3 (Rotary SW)
    0 - FOn Line (Call processing is in progress)
    2Off Line (Call processing is stopped)
    • I/O port : Depending on 
    CM40 YY=08
    3Off Line (Call processing is stopped)
    • I/O port : 1200bps (Fixed)
    B For clearing the office data
    C For setting the resident system program
    1, 4 - 9
    A, D - FNot used
    SW1 (Push SW) For initializing the CPU
    SW2 (Piano Key SW)
    1ON KF Mode
    MF/PF Mode
    2, 3Selection of PLO (Phase Locked Oscillator)
    • When using the internal PLO of MP card:
    0
    ON
    OFF
    4
    3
    2
    1
     
    
    
    
    
    
    
    OFF
    SWITCH 
    OFF
    ON1.5MHz clock 
    [For PN-24DTA/PN-24DTA-A]
    192kHz clock 
    [For PN-BRTA]
    2MHz clock 
    [For PN-30DTC]
    Not used  OFF OFF
    ON OFF
    ON ON
    FUNCTION
    23 NUMBER 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 30
    Revision 2.0
    NAP-200-008
    Sheet 4/13
    Switch Setting of Circuit Card
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Note :Set the groove on the switch knob to the desired switch position.
    Table 008-4 PN-CP03 (MP) Card Switch Settings (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW2 (Piano Key SW)
    2, 3
    • When using the PLO card (PN-CK00):
    SW2-2
    SW2-3
    OFF ON
    • When not using the internal PLO and the PLO card:
    SW2-2
    SW2-3
    OFF OFF
    4
    ONWhen using RS1 port for built-in 
    MODEM.
    OFF When using RS1 port for RS-232C.
    VR (Rotary SW)
    Variable Resistor for External Hold 
    Tone Source
    (0 - 20 KW : Clockwise)
    JP0 (Jumper pin)
    For normal operation
    DOWN Not used
    JP1 (Jumper pin)
    For normal operation
    DOWN For using External Tone SourceON
    OFF
    4
    3
    2
    1
     
    
    
    
    
    
    
    
    20
    0
    Front
    UP
    Front
    UP 
    						
    							ND-46551 (E) CHAPTER 3
    Page 131
    Revision 2.0
    NAP-200-008
    Sheet 5/13
    Switch Setting of Circuit Card
    CAUTION:When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
    card into/from its mounting slot.
    3. PZ-PW86 (PWR)
    (1) Locations of Lamps, Switches, and Connectors
    Figure 008-2  PZ-PW86 (PWR) Card
    FRONT VIEW BATT2MN MJ
    ONBATTERY
    SIDE VIEW GND
    –27V FG
    OFFON
    240VAC 100/120VAC 2ON
    2
    1 ON
    SW301 START
    SIG
    1
    SW1
    BATT1
    AC INPUTMODE
    SW102 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 32
    Revision 2.0
    NAP-200-008
    Sheet 6/13
    Switch Setting of Circuit Card
    (2) Lamp Indications
    Table 008-5  PZ-PW86(C) (PWR) Card Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major fault.
    MN Orange Lights upon occurrence of a minor fault.
    ON Green Remains lit while the power is on. 
    						
    							ND-46551 (E) CHAPTER 3
    Page 133
    Revision 2.0
    NAP-200-008
    Sheet 7/13
    Switch Setting of Circuit Card
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Table 008-6  PZ-PW86(C) (PWR) Card Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW101 (Piano Key SW)
    1 Always set to OFF
    2Float charging for sealed batteries (Nor-
    mal Setting).
    OPTION: Periodic equalize charging of 
    external vented batteries.
    (set to equalize for Gel cell or no 
    battery).
    OFF Float charging, for vented
     batteries only.
    SW
    For turning AC power and the battery on
    OFFFor turning AC power and the battery off
    SW102 BATTERY START
    PRESS MO-
    MENTARILYTo start each PIM on battery power,
    when AC power is not provided 
    (switch “SW” must be ON)
    AC INPUT: 90 V - 138 V
    DOWN AC INPUT: 180 V - 264 V
    SW301
    1ON CR Voltage: 75 Vrms
    OFF CR Voltage: 90 Vrms
    2ON Frequency: 20 Hz
    OFF Frequency: 25 Hz
    1
    2
    ON
    OFF
    ON
    ON (–)
    OFF (O)
    ON
    240 VAC 100/120 VAC
    UP
    2
    1ONOFF 20Hz 25Hz
    75V 90V 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 34
    Revision 2.0
    NAP-200-008
    Sheet 8/13
    Switch Setting of Circuit Card
    4. PZ-PW86(D) (PWR)
    (4) Locations of Lamps, Switches and Connectors
    Figure 008-3  PZ-PW86(D) (PWR) Card
    (2) Lamp Indications
    Table 008-7  PZ-PW86(D) (PWR) Card Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major trouble
    MN Orange Lights upon occurrence of a minor trouble
    ON Green Remains lit while the operating power is being supplied
    FRONT VIEWBATT2 MN MJ
    ON
    BATTERY
    SIDE VIEW GND
    –27V FG
    OFFON 240VAC 100/120VAC2ON
    2
    1 ON SW102
    START
    SIG
    1
    SW1 BATT1
    AC INPUTMODE
    SW301
    (CN103) SIG
    (CN103) 
    						
    							ND-46551 (E) CHAPTER 3
    Page 135
    Revision 2.0
    NAP-200-008
    Sheet 9/13
    Switch Setting of Circuit Card
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
    indicate the standard setting of the switch. When the switch is not set as shown by the figure and   ,
    the setting of the switch varies with the system concerned.
    Table 008-8  PZ-PW86(D) (PWR) Card Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    MODE
    1Always set to OFF
    2Float charging, for sealed batteries
    (Normal Setting).
    OPTION: Periodic Equalize charging
    of external vented batteries.
    OFFFloat charging, for vented batteries
    only.
    SW1 For turning AC power and the battery
    on
    OFFFor turning AC power and the battery
    off
    AC INPUT: 90 V - 138 V
    DOWN AC INPUT: 180 V - 264 V
    SW102
    PRESS MO-
    MENTARILYTo start each PIM on battery power,
    when AC power is not provided
    (switch “SW” must be ON)
    SW301
    1ON CR Voltage: 75 Vrms
    CR Voltage: 90 Vrms
    2Frequency: 20 Hz
    OFF Frequency: 25 Hz
    ON
    1
    2
    OFF
    ON
    OFF (O) ON (I)
    ON
    240 VAC 100/120 VAC
    UP
    25Hz
    1 2
    OFF
    90V 20Hz
    ON
    75V
    OFF
    ON 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 36
    Revision 2.0
    NAP-200-008
    Sheet 10/13
    Switch Setting of Circuit Card
    5. PN-PW00 (EXTPWR)
    (4) Locations of Lamps, Switches and Connectors
    Figure 008-4  PN-PW00 (EXTPWR) Card
    (2) Lamp Indications
    Table 008-9  PN-PW00 (EXTPWR) Card Lamp Indications 
    LAMP NAME COLOR FUNCTION
    RUN Green Remains lit while –48 V power is being supplied
    RUN
    MB
    CONN 
    						
    							ND-46551 (E) CHAPTER 3
    Page 137
    Revision 2.0
    NAP-200-008
    Sheet 11/13
    Switch Setting of Circuit Card
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION column indicate
    the standard setting of the switch. When the switch is not set as shown by the figure and  , the setting of the
    switch varies with the system concerned.
    Note :When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.Table 008-10  PN-PW00 (EXTPWR) Card Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    MB (Toggle SW)
    Note
    UP For make-busy (–48 V power off)
    For normal operation (–48 V power on)
    ON
    DOWN 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 38
    Revision 2.0
    NAP-200-008
    Sheet 12/13
    Switch Setting of Circuit Card
    6. PN-8DLCJ/8DLCP (DLC)
    (1) Locations of Lamps, Switches and Connectors
    Figure 008-5  PN-8DLCJ/8DLCP (DLC) Card
    (2) Lamp Indications
    • Switch Settings
    This card has no switches.
    Table 008-11   PN-8DLCJ8DLCP (DLC) Card Lamp Indications
    LAMP NAME COLOR FUNCTION
    BL0 - 7 Red• Remains lit when the corresponding circuit is in use.
    • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the sys-
    tem data for this card is not assigned.
    BL7
    BL4BL6
    BL5
    BL3
    BL2
    BL0 BL1 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax2000 Ivs Small Platform System Manual