ND-46551 (E) CHAPTER 3 Page 139 Revision 2.0 NAP-200-008 Sheet 13/13 Switch Setting of Circuit Card 7. PN-8LCS (LC) (1) Locations of Lamps, Switches and Connectors Figure 008-6 PN-8LCS (LC) Card (2) Lamp Indications (3) Switch Settings This card has no switches. Table 008-12 PN-8LCS (LC) Card Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 7 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. BL7 BL4BL6 BL5 BL3 BL2 BL0 BL1
CHAPTER 3 ND-46551 (E) Pag e 1 40 Revision 2.0 NAP-200-009 Sheet 1/3 Mounting of Circuit Cards 1. MOUNTING PROCEDURE (1) For testing, turn on “SW1” switch on the PZ-PW86 Card. Make sure that “ON” lamp (Green) is lit. (2) Turn off “SW1” switch. Figure 009-1 PZ-PW86(C) Card Lamp Indication PZ-PW86 ON OFFSW1 SWITCH ON LAMP (GREEN) MN MJ ON
ND -4 6551 ( E) CHAPTER 3 NAP-200-0 09 CARD FRONT SIDE WR IST STRAP TO FRA ME GROUND CONNECTION CARD CONT ACT S IDE
CHAPTER 3 ND -4 6551 ( E) NAP-2 00-0 09 A B F ig . A
ND-46551 (E) CHAPTER 3 Page 143 Revision 2.0 NAP-200-010 Sheet 1/7 System Initialization and System Data Entr y 1. SYSTEM INITIALIZATION • There are two methods for System Initialization. The first method is to Clear All Data, except LEN0000 as a CAT terminal, and then program the System Data. The second method is to use the Resident System Program, which causes the system to configure itself automatically to the default settings, wherever the line/trunk cards are installed. Refer to the System Data Sheet, for the default settings. • Turn on the “SW1” switch on the PZ-PW86 card. - The “ON” lamp must be lit on the PZ-PW86 card. 1.1 All Clear, Except LEN0000 CAT STEP 1: On the MP Card, set SW3 to “B” and press SW1. STEP 2: When the “MN” lamp on the system is lit, set SW3 to the “0” position and press SW1. - The operating mode has been changed to the ON LINE mode. 1.2 Resident System Program STEP 1: Mount the Line/Trunk cards into PIM. STEP 2: On the MP Card, set SW3 to “C” and press SW1. - After 30 to 40 seconds, the “MN” lamp turns on. - The system has loaded the Resident System Program. Note:If the “MJ” lamp is lit, repeat Step 2. STEP 3:Set SW3 to the “0” position and press SW1. - The operating mode has been changed to the ON LINE mode. Note:Refer to the System Data Sheet for additional information on the Resident System Program and the initialization of the system without a MAT (enabling CAT mode).
CHAPTER 3 ND-46551 (E) Pag e 1 44 Revision 2.0 NAP-200-010 Sheet 2/7 System Initialization and System Data Entr y 2. SYSTEM DATA ENTRY • There are two methods for data entry, both of which employ a Customer Administration Terminal (CAT) or a Maintenance Administration Terminal (MAT). 2.1 CAT Any Multiline Terminal can be assigned as a CAT terminal through programming. The Multiline Terminal can still be used as a regular telephone when it is not in CAT mode. If the system is initialized by “C” (Resident System Program), every Multiline Terminal will be able to go into CAT mode. If the system is initialized by “B” (All Clear), only LEN0000 is assigned as a CAT port (the DLC card must be installed in slot LT00). To use a Multiline Terminal as a CAT, follow the procedures shown below. To set CAT mode: (1) Press (2) Press - CNF lamp flashes (3) Press - CNF lamp is off (4) Press (5) Press - CNF lamp flashes (6) Press - CNF, SPKR, ANS lamps are lit - “CAT MODE” is displayed on the LCD (7) Press - “COMMAND = -” is displayed on the LCD Note:Steps 1 through 6 need to be completed within four (4) seconds. TRF CNF * TRF CNF # ST ATTENTIONContents Static Sensitive Handling Precautions Required
ND-46551 (E) CHAPTER 3 Page 145 Revision 2.0 NAP-200-010 Sheet 3/7 System Initialization and System Data Entr y To reset CAT mode: While “COMMAND = -” is displayed on the LCD: (1) Lift the handset (off hook) - SPKR lamp turns off. (2) Restore the handset (on hook) - CNF, ANS lamps turn off. - LCD returns to clock. 2.2 MAT In addition to the CAT mode programming, the MAT can also be used in the MAT mode. Refer to the MAT Oper- ation Guide and the Command Manual. 2.3 Feature Programming This section provides the feature programming (Music On Hold, Push Button Calling) related to the internal PB Re- ceiver and internal TNT on the MP card. For the other feature programming, refer to the Feature Programming Man- ual. In the programming procedure, the meaning of (1), (2) and marking are as follows: (1) : 1st Data (2) : 2nd Data : Initial Data With the system data clear command (CM00, CM01), the data with this marking ( ) is automatically assigned for each command. : System Initialization After entering the data, system initialization is required (Depress SW1 of MP card). INITIAL ATTENTIONContents Static Sensitive Handling Precautions Required
CHAPTER 3 ND-46551 (E) Pag e 1 46 Revision 2.0 NAP-200-010 Sheet 4/7 System Initialization and System Data Entr y (1) Programming Procedure for Music On Hold For providing Hold Tone Source on the MP card: For providing External Hold Tone Source through the MP card: DESCRIPTION DATA Select the music to be provided. (1) 183 (2) 0: Nocturne 1 : Minuet Define the type of call to be provided with Hold Tone on the MP card. Note:When using the MP card, set the JP1 switch to UP (Internal Hold Tone Source)..Y = 0 (1) 00: C.O. Line Call 01: Tie Line Call 02: Internal Call (2) 1400: Hold Tone Source on MP card DESCRIPTION DATA Define the type of call to be provided with Hold Tone..Y = 0 (1) 00: C.O. Line Call 01: Tie Line Call 02: Internal Call (2) 1400: Hold Tone Source through MP cardSTART CM08 CM48 END START CM48 END
ND-46551 (E) CHAPTER 3 Page 147 Revision 2.0 NAP-200-010 Sheet 5/7 System Initialization and System Data Entr y For providing External Hold Tone Source through MP card: • External Hold Tone Source provided locally For connecting the External Hold Tone Source, plug the cable into JACK on the MP card. Set the switches on the MP card as follows: For providing Hold Tone Source on the MP card: Set the JP1 switch to UP. PBX MP CARD JACKEXTERNAL HOLD TONE SOURCE JP1 VR MP CARD JP1: INTERNAL/EXTERNAL HOLD TONE SOURCE VR: VARIABLE RESISTOR FOR EXTERNAL HOLD TONE SOURCE (0-20k W: CLOCKWISE) UP: DOWN: EXTERNAL HOLD TONE SOURCE INTERNAL HOLD TONE SOURCE : POSITION TO BE SET 20 0
CHAPTER 3 ND-46551 (E) Pag e 1 48 Revision 2.0 NAP-200-010 Sheet 6/7 System Initialization and System Data Entr y (2) Programming Procedure for Push button Calling DESCRIPTION DATA Assign the Card Number of internal PB Receiver to the LEN No. 0124. Note:When using the internal PB Receiver on the MP card, assign the Card No. E200- E203 to the LEN No. 0124. If resident load is used, PB Receiver ports (E200-LENS 0124) are automatically as- signed.(1) LEN: 0124 (2) E200-E203 (PB Receiver No.) Assign the type of telephone set (DTMF) to DTMF Stations. This data assignment is not required for Multiline Terminal station..YY = 00 (1) X-XXXX (Station No.) (2) 2 : DTMF Telephone set Assign PB Receivers for use with DTMF Stations..Y = 0 (Make Busy) (1) XX X (2) :Make Busy Cancel .Y = 1 (Purpose) (1) XXX (Ditto to Y = 0) (2) 1 :For both DTMF station and Tie Line/ DIDSTART CM10 A CM12 CM45INITIAL Circuit No. 0-3 Card No. 00-03 assigned by CM10(E200-E203)