    							ND-46551 (E) CHAPTER 3
    Page 139
    Revision 2.0
    NAP-200-008
    Sheet 13/13
    Switch Setting of Circuit Card
    7. PN-8LCS (LC)
    (1) Locations of Lamps, Switches and Connectors
    Figure 008-6  PN-8LCS (LC) Card
    (2) Lamp Indications
    (3) Switch Settings
    This card has no switches.
    Table 008-12  PN-8LCS (LC) Card Lamp Indications
    LAMP NAME COLOR FUNCTION
    BL0 - 7 Red• Remains lit when the corresponding circuit is in use.
    • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the 
    system data for this card is not assigned.
    BL7
    BL4BL6
    BL5
    BL3
    BL2
    BL0 BL1 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 40
    Revision 2.0
    NAP-200-009
    Sheet 1/3
    Mounting of Circuit Cards
    1. MOUNTING PROCEDURE
    (1) For testing, turn on “SW1” switch on the PZ-PW86 Card.  Make sure that “ON” lamp (Green) is lit.
    (2) Turn off “SW1” switch.
    Figure 009-1  PZ-PW86(C) Card Lamp Indication
    PZ-PW86
    ON
    OFFSW1 SWITCH
    ON LAMP (GREEN)
    MN
    MJ
    ON 
    						
    							ND -4 6551 ( E)  CHAPTER 3
    NAP-200-0 09
    CARD  FRONT  SIDE
    WR IST  STRAP
    TO  FRA ME GROUND  CONNECTION
    CARD CONT ACT S IDE 
    						
    							CHAPTER 3  ND -4 6551 ( E)
    NAP-2 00-0 09
    A
    B
    F ig . A 
    						
    							ND-46551 (E) CHAPTER 3
    Page 143
    Revision 2.0
    NAP-200-010
    Sheet 1/7
    System Initialization and 
    System Data Entr y
    1. SYSTEM INITIALIZATION
    • There are two methods for System Initialization.  The first method is to Clear All Data, except LEN0000
    as a CAT terminal, and then program the System Data.  The second method is to use the Resident System
    Program, which causes the system to configure itself automatically to the default settings, wherever the
    line/trunk cards are installed.  Refer to the System Data Sheet, for the default settings. 
    • Turn on the “SW1” switch on the PZ-PW86 card.
    - The “ON” lamp must be lit on the PZ-PW86 card.
    1.1 All Clear, Except LEN0000 CAT
    STEP 1:
    On the MP Card, set SW3 to “B” and press SW1.
    STEP 2:
    When the “MN” lamp on the system is lit, set SW3 to the “0” position and press SW1.
    - The operating mode has been changed to the ON LINE mode.
    1.2 Resident System Program
    STEP 1:
    Mount the Line/Trunk cards into PIM.
    STEP 2:
    On the MP Card, set SW3 to “C” and press SW1.
    - After 30 to 40 seconds, the “MN” lamp turns on.
    - The system has loaded the Resident System Program.
    Note:If the “MJ” lamp is lit, repeat Step 2.
    STEP 3:Set SW3 to the “0” position and press SW1.
    - The operating mode has been changed to the ON LINE mode.
    Note:Refer to the System Data Sheet for additional information on the Resident System Program and the initialization of
    the system without a MAT (enabling CAT mode). 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 44
    Revision 2.0
    NAP-200-010
    Sheet 2/7
    System Initialization and 
    System Data Entr y
    2. SYSTEM DATA ENTRY
    • There are two methods for data entry, both of which employ a Customer Administration Terminal (CAT)
    or a Maintenance Administration Terminal (MAT).
    2.1 CAT
    Any Multiline Terminal can be assigned as a CAT terminal through programming.  The Multiline Terminal can still
    be used as a regular telephone when it is not in CAT mode.  If the system is initialized by “C” (Resident System
    Program), every Multiline Terminal will be able to go into CAT mode.  If the system is initialized by “B” (All Clear),
    only LEN0000 is assigned as a CAT port (the DLC card must be installed in slot LT00).
    To use a Multiline Terminal as a CAT, follow the procedures shown below.
    To set CAT mode:
    (1) Press
    (2) Press
    - CNF lamp flashes
    (3) Press
    - CNF lamp is off
    (4) Press
    (5) Press
    - CNF lamp flashes
    (6) Press
    - CNF, SPKR, ANS lamps are lit
    - “CAT MODE” is displayed on the LCD
    (7) Press
    - “COMMAND = -” is displayed on the LCD
    Note:Steps 1 through 6 need to be completed within four (4) seconds.
    TRF
    CNF
    *
    TRF
    CNF
    #
    ST
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							ND-46551 (E) CHAPTER 3
    Page 145
    Revision 2.0
    NAP-200-010
    Sheet 3/7
    System Initialization and 
    System Data Entr y
    To reset CAT mode:
    While “COMMAND = -” is displayed on the LCD:
    (1) Lift the handset (off hook)
    - SPKR lamp turns off.
    (2) Restore the handset (on hook)
    - CNF, ANS lamps turn off.
    - LCD returns to clock.
    2.2 MAT
    In addition to the CAT mode programming, the MAT can also be used in the MAT mode.  Refer to the MAT Oper-
    ation Guide and the Command Manual.
    2.3 Feature Programming
    This section provides the feature programming (Music On Hold, Push Button Calling) related to the internal PB Re-
    ceiver and internal TNT on the MP card. For the other feature programming, refer to the Feature Programming Man-
    ual.
    In the programming procedure, the meaning of (1), (2) and marking are as follows:
    (1) : 1st Data
    (2) : 2nd Data
    : Initial Data
    With the system data clear command (CM00, CM01), the data with this marking ( ) is automatically assigned
    for each command.
    : System Initialization
    After entering the data, system initialization is required (Depress SW1 of MP card).
    INITIAL
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 46
    Revision 2.0
    NAP-200-010
    Sheet 4/7
    System Initialization and 
    System Data Entr y
    (1) Programming Procedure for Music On Hold
    For providing Hold Tone Source on the MP card:
    For providing External Hold Tone Source through the MP card:
    DESCRIPTION DATA
    Select the music to be provided. (1) 183
    (2) 0: Nocturne
    1 : Minuet
    Define the type of call to be provided with Hold Tone 
    on the MP card.
    Note:When using the MP card, set the JP1
    switch to UP (Internal Hold Tone Source)..Y = 0
    (1) 00: C.O. Line Call
    01: Tie Line Call
    02: Internal Call
    (2) 1400: Hold Tone Source on MP card
    DESCRIPTION DATA
    Define the type of call to be provided with Hold 
    Tone..Y = 0
    (1) 00: C.O. Line Call
    01: Tie Line Call
    02: Internal Call
    (2) 1400: Hold Tone Source through MP cardSTART
    CM08
    CM48
    END
    START
    CM48
    END 
    						
    							ND-46551 (E) CHAPTER 3
    Page 147
    Revision 2.0
    NAP-200-010
    Sheet 5/7
    System Initialization and 
    System Data Entr y
    For providing External Hold Tone Source through MP card:
    • External Hold Tone Source provided locally
    For connecting the External Hold Tone Source, plug the cable into JACK on the MP card.
    Set the switches on the MP card as follows:
    For providing Hold Tone Source on the MP card: Set the JP1 switch to UP.
    PBX
    MP CARD
    JACKEXTERNAL HOLD TONE SOURCE
    JP1
    VR
    MP CARD
    JP1: INTERNAL/EXTERNAL
    HOLD TONE SOURCE
    VR: VARIABLE RESISTOR FOR
    EXTERNAL HOLD TONE SOURCE
    (0-20k
    W: CLOCKWISE)
    UP:
    DOWN: EXTERNAL HOLD
    TONE SOURCE INTERNAL HOLD
    TONE SOURCE
    : POSITION TO BE SET
    20
    0 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 1 48
    Revision 2.0
    NAP-200-010
    Sheet 6/7
    System Initialization and 
    System Data Entr y
    (2) Programming Procedure for Push button Calling
    DESCRIPTION DATA
    Assign the Card Number of internal PB Receiver to 
    the LEN No. 0124.
    Note:When using the internal PB Receiver on
    the MP card, assign the Card No. E200-
    E203 to the LEN No. 0124.
    If resident load is used, PB Receiver ports
    (E200-LENS 0124) are automatically as-
    signed.(1) LEN: 0124
    (2) E200-E203 (PB Receiver No.)
    Assign the type of telephone set (DTMF) to DTMF 
    Stations.
    This data assignment is not required for Multiline 
    Terminal station..YY = 00
    (1) X-XXXX (Station No.)
    (2) 2 : DTMF Telephone set
    Assign PB Receivers for use with DTMF 
    Stations..Y = 0 (Make Busy)
    (1) XX X 
    (2) :Make Busy Cancel
    .Y = 1 (Purpose)
    (1) XXX (Ditto to Y = 0)
    (2) 1 :For both DTMF station and Tie Line/
    DIDSTART
    CM10
    A
    CM12
    CM45INITIAL
    Circuit No. 0-3
    Card No. 00-03 assigned by
    CM10(E200-E203) 
    						