ND -4 6551 ( E) CHAPTER 3 NAP-200-005 LT C CONN EC TOR CHAMP CONN EC TOR FR ONTTIE WR AP 25 ~ 3 0 mm(1 .0 ~ 1 .2 inc h)
CHAPTER 3 ND -4 6551 ( E) NAP-200-0 05 LT C CONN EC TOR CHAMP CONN EC TOR FR ONTTIE WR AP 25 ~ 3 0 mm(1 .0 ~ 1 .2 inc h)
ND-46551 (E) CHAPTER 3 Page 61 Revision 2.0 NAP-200-005 Sheet 5/5 Cable Running to the MDF (3) Connect the MDF cables to the MDF connectors in the MDFM. Figure 005-5 MDF Cable Connection to MDFM Example LTC0LTC1 LTC2 PIMBWB MDF CABLE MDF CONNECTOR MDFM LOCAL SIDE PBX SIDE
CHAPTER 3 ND-46551 (E) Pag e 6 2 Revision 2.0 NAP-200-006 Sheet 1/54 Termination of Cables on the MDF 1. CABLE CONNECTION TO THE MDF (1) Connect the cables to the MDF referring to Figure 006-1 and Table 006-1. Figure 006-1 Card Slots and LTC Connectors Location (PIM0) Note :When using the internal DTMF Receiver on the MP card, assign the Card No. E200 to the LEN No. 0124.Table 006-1 LTC Connector Accommodation LTC CONNECTOR CARD SLOT NUMBER REMARKS LT C 0 LT 0 0 ~ LT 0 5 LT C 1 LT 0 6 ~ LT 0 9 , LT 1 0 / A P 0 , LT 1 1 / A P 1 LT C 2 LT 1 2 / A P 2 ~ LT 1 5 / A P 5 , A P 6 LTC1LTC0LTC2 BWB FRONT P W R LT10/AP4LT00LT01LT02LT03LT04LT05FP/AP6 PIM 0 MP/FP/AP7BUS/AP8LT06LT07LT08LT09LT10/AP0LT10/AP1LT10/AP2LT10/AP3LT10/AP5
ND -4 6551 ( E) CHAPTER 3 NAP-200-006 LT 09/A P 3LT 08/AP2LT 07/A P1 LT C 1LT C 0LT C 2 BWB P LT 10 /A P 4LT 00LT01LT02LT03LT 04LT05LT06/A P0 AP5MP
CHAPTER 3 ND-46551 (E) Pag e 6 4 Revision 2.0 NAP-200-006 Sheet 3/54 Termination of Cables on the MDF (3) The figure below shows the relationship between each Line Equipment Number (LEN) and each Card Slot Number (LT Number). (a) LEN 0000 ~ 0143 Figure 006-3 Location of Each LEN Note 1:Do not mount line/trunk circuit card with cabling in this slot; this slot has no connection to the MDF via the backplane, except M03. Note 2:When using the internal DTMF Receiver on the MP card, assign the Card No. E200 to the LEN No. 0124. 0079 0078 0077 0076 0075 0074 0073 0072 (LT01)0087 0086 0085 0084 0083 0082 0081 0080 (LT02)0095 0094 0093 0092 0091 0090 0089 0088 (LT03)0103 0102 0101 0100 0099 0098 0097 0096 (LT04)0111 0110 0109 0108 0107 0106 0105 0104 (LT05)0119 0118 0117 0116 0115 0114 0113 0112 (LT06)0127 0126 0125 0124 0123 0122 0121 0120 (LT07)0135 0134 0133 0132 0131 0130 0129 0128 (LT08)_ _ _ _ 0139 0138 0137 0136 (LT09)_ _ _ _ 0143 0142 0141 0140 (LT10) 0003 0002 0001 0000 (LT00)0007 0006 0005 0004 (LT01)0011 0010 0009 0008 (LT02)0015 0014 0013 0012 (LT03)0019 0018 0017 0016 (LT04)0023 0022 0021 0020 (LT05)0027 0026 0025 0024 (LT06)0031 0030 0029 0028 (LT07)0035 0034 0033 0032 (LT08)0039 0038 0037 0036 (LT09)0043 0042 0041 0040 (LT10)0047 0046 0045 0044 (LT11)0051 0050 0049 0048 (LT12)0055 0054 0053 0052 (LT13)0059 0058 0057 0056 (LT14)0063 0062 0061 0060 (LT15) 0071 0070 0069 0068 0067 0066 0065 0064 (LT00) PIM1 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ (LT ´ ´) LEN (LINE EQUIPMENT NUMBER) CARD SLOT NUMBER Note 1 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ 0 ´ ´ ´ (LT ´ ´) LEN (LINE EQUIPMENT NUMBER) CARD SLOT NUMBER PIM0
ND-46551 (E) CHAPTER 3 Page 65 Revision 2.0 NAP-200-006 Sheet 4/54 Termination of Cables on the MDF (4) The figure below shows the LTC Connector Pin Arrangement. (a) PIM0 (LTC0 ~ LTC2) Figure 006-4 LTC Connector Pin Arrangement (PIM0) LTC2 26 1 LEN0048 LT12/AP2 27 2 0049 28 3 0050 29 4 0051 30 5 0052 LT13/AP3 31 6 0053 32 7 0054 33 8 0055 34 9 0056 LT14/AP4 35 10 0057 36 11 0058 37 12 0059 38 13 0060 LT15/AP5 39 14 0061 40 15 0062 41 16 LEN0063 42 17 AP6 Note:43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 LTC0 26 1 LEN0000 LT00 27 2 0001 28 3 0002 29 4 0003 30 5 0004 LT01 31 6 0005 32 7 0006 33 8 0007 34 9 0008 LT02 35 10 0009 36 11 0010 37 12 0011 38 13 0012 LT03 39 14 0013 40 15 0014 41 16 0015 42 17 0016 LT04 43 18 0017 44 19 0018 45 20 0019 46 21 0020 LT05 47 22 0021 48 23 0022 49 24 LEN0023 50 MN 25 MJ LTC1 26 1 LEN0024 LT06 27 2 0025 28 3 0026 29 4 0027 30 5 0028 LT07 31 6 0029 32 7 0030 33 8 0031 34 9 0032 LT08 35 10 0033 36 11 0034 37 12 0035 38 13 0036 LT09 39 14 0037 40 15 0038 41 16 0039 42 17 0040 LT10/AP0 43 18 0041 44 19 0042 45 20 0043 46 21 0044 LT11/AP1 47 22 0045 48 23 0046 49 24 LEN0047 50 25 These pins are used only for the PN-24DTA.
CHAPTER 3 ND-46551 (E) Pag e 6 6 Revision 2.0 NAP-200-006 Sheet 5/54 Termination of Cables on the MDF 2. MDF CROSS CONNECTIONS (1) Cross connections on the MDF for LTC0 through LTC2 are shown in Table 006-3 and Table 006-4. Table 006-3 LTC0-LTC2 MDF Cross Connection Information PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE CO (4COT)CO (2COT)2-WIRE E&M TIE LINE (2ODT)4-WIRE E&M TIE LINE (2ODT)DID (AUC)SLT (4LC)SLT (AUC) 26 WH-BL GN 1 T0 T0 T0 TxT0 T0 T0 T0 1 BL-WH RD R0 R0 R0 TxR0 R0 R0 R0 27 WH-OR BK T1 T1 T1 RcvT0 T1 T1 T1 2 OR-WH YL R1 R1 R1 RcvR0 R1 R1 R1 28 WH-GN GN T2 T2 TxT1 T2 3 GN-WH RD R2 R2 TxR1 R2 29 WH-BR BK T3 T3 RcvT1 T3 4 BR-WH YL R3 R3 RcvR1 R3 30 WH-SL GN 2 T0 T0 T0 TxT0 T0 T0 T0 5 SL-WH RD R0 R0 R0 TxR0 R0 R0 R0 31 RD-BL BK T1 T1 T1 RcvT0 T1 T1 T1 6 BL-RD YL R1 R1 R1 RcvR0 R1 R1 R1 32 RD-OR GN T2 T2 TxT1 T2 7 OR-RD RD R2 R2 TxR1 R2 33 RD-GN BK T3 T3 RcvT1 T3 8 GN-RD YL R3 R3 RcvR1 R3 34 RD-BR GN 3 T0 T0 T0 TxT0 T0 T0 T0 9 BR-RD RD R0 R0 R0 TxR0 R0 R0 R0 35 RD-SL BK T1 T1 T1 RcvT0 T1 T1 T1 10 SL-RD YL R1 R1 R1 RcvR0 R1 R1 R1 36 BK-BL GN T2 T2 TxT1 T2 11 BL-BK RD R2 R2 TxR1 R2 37 BK-OR BK T3 T3 RcvT1 T3 12 OR-BK YL R3 R3 RcvR1 R3
ND-46551 (E) CHAPTER 3 Page 67 Revision 2.0 NAP-200-006 Sheet 6/54 Termination of Cables on the MDF * Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.Table 006-3 LTC0-LTC2 MDF Cross Connection Information (Continued) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE COT (4COT)COT (2COT)2-WIRE E&M TIE LINE (2ODT)4-WIRE E&M TIE LINE (2ODT)DID (AUC)SLT (4LC)SLT (AUC) 38 BK-GN GN 4T0 T0 T0 TxT0 T0 T0 T0 13 GN-BK RD R0 R0 R0 TxR0 R0 R0 R0 39 BK-BR BK T1 T1 T1 RcvT0 T1 T1 T1 14 BR-BK YL R1 R1 R1 RcvR0 R1 R1 R1 40 BK-SL GN T2 T2 TxT1 T2 15 SL-BK RD R2 R2 TxR1 R2 41 YL-BL BK T3 T3 RcvT1 T3 16 BL-YL YL R3 R3 RcvR1 R3 42 YL-OR GN 5T0 T0 T0 TxT0 T0 T0 T0 17OR-YL RD R0R0 R0 TxR0R0R0R0 43 YL-GN BK T1 T1 T1 RcvT0 T1 T1 T1 18 GN-YL YL R1 R1 R1 RcvR0 R1 R1 R1 44 YL-BR GN T2 T2 TxT1 T2 19 BR-YL RD R2 R2 TxR1 R2 45 YL-SL BK T3 T3 RcvT1 T3 20 SL-YL YL R3 R3 RcvR1 R3 46 VI-BL GN 6T0 T0 T0 TxT0 T0 T0 T0 21BL-VI RD R0R0 R0 TxR0R0R0R0 47 VI-OR BK T1 T1 T1 RcvT0 T1 T1 T1 22 OR-VI YL R1 R1 R1 RcvR0 R1 R1 R1 48 VI-GN GN T2 T2 TxT1 T2 23 GN-VI RD R2 R2 TxR1 R2 49 VI-BR BK T3 T3 RcvT1 T3 24 BR-VI YL R3 R3 RcvR1 R3 50 VI-SL MN * 25 SL-VI MJ *
CHAPTER 3 ND-46551 (E) Pag e 6 8 Revision 2.0 NAP-200-006 Sheet 7/54 Termination of Cables on the MDF Note 1:2-wire type for Multiline Terminal/DSS Console/SN716 DESKCON. Note 2:4-wire type for Multiline Terminal/SN610 ATTCON.Table 006-3 LTC0-LTC2 MDF Cross Connection Information (Continued) PINRU NN ING CABLESTATION CABLESLOTSTYPE OF INTERFACE D term/ SN716 DESKCON (4DLC) Note 1Dterm/ SN716 DESKCON (2DLC) Note 1Dterm (4DLC) Note 2SN610 AT T C O N (2DLC) Note 2EXT. KEY/ EXT. RELAY (DK00)EXT. PAG E / M O H / BGM (4COT) 26 1WH-BL BL-WHGN RD 1T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 27 2WH-OR OR-WHBK YLT1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 28 3WH-GN GN-WHGN RDT2 R2RA1 TA 1RA1 TA 1K5 K4T R 29 4WH-BR BR-WHBK YLT3 R3RB1 TB1RB1 TB1K7 K6T R 30 5WH-SL SL-WHGN RD 2T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 31 6RD-BL BL-RDBK YLT1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 32 7RD-OR OR-RDGN RDT2 R2RA1 TA 1RA1 TA 1K5 K4T R 33 8RD-GN GN-RDBK YLT3 R3RB1 TB1RB1 TB1K7 K6T R 34 9RD-BR BR-RDGN RD 3T0 R0T0 R0RA0 TA 0RA0 TA 0K1 K0T R 35 10RD-SL SL-RDBK YLT1 R1T1 R1RB0 TB0RB0 TB0K3 K2T R 36 11BK-BL BL-BKGN RDT2 R2RA1 TA 1RA1 TA 1K5 K4T R 37 12BK-OR OR-BKBK YLT3 R3RB1 TB1RB1 TB1K7 K6T R