CHAPTER 2 ND-46551 (E) Pag e 8 Revision 2.0 Figure 2-5 Desk Top Installation PIM
ND-46551 (E) CHAPTER 2 Page 9 Revision 2.0 3. FUNCTIONAL OUTLINE OF EQUIPMENT This section explains the functional outline of the equipment (modules, installation hardware, circuit cards) used in the PBX. 3.1 Functional Outline of Modules Table 2-2 shows the functional outline of the modules. Table 2-2 Functional Outline of Modules MODULESFUNCTIONAL NAMEFUNCTIONAL OUTLINE SN1308 PIMQ-UA PIMPort Interface Module (PIM) A PIM provides 13 card slot for common control, Line/Trunk, and Applica- tion Processor (AP) cards. It also houses a AC/DC Power Supply and op- tional batteries for protection from short-term power interruption (standard). Three champ connectors for line/trunk (LTC0 to 2) and a connector for Pow- er (PWR) are located at the lower front side of the PIM. A PIM provides a maximum of 11 card slots for line/trunk (LT) cards. At maximum configuration, the system is comprised of 1 PIM and it provides 72 ports. SN1228 MDFM-A MDFMMain Distribution Frame Module (MDFM) The MDFM is available for floor standing or IEC standard 19 inch rack mounting. (When the system is Wall Mounting or Desk Top configuration, the MDFM can not install with PIM.) SN1177 BATTM-A BATTMThe BATTM is an optional module for installing optional long-term back- up batteries. The BATTM is available for floor standing or IEC standard 19-inch rack mounting. (When the system is Wall Mounting or Desk Top configuration, the BATTM can not install with PIM.) Requirements for batteries installed in the BATTM are as follows: • Battery Type : Lead-Acid • Battery Capacity : 24V/24AH (2 sets maximum) • Battery Weight : 19.8lb. (9kg) maximum
CHAPTER 2 ND-46551 (E) Pag e 1 0 Revision 2.0 3.2 Functional Outline of Installation Hardware Table 2-3 shows the functional outline of installation hardware. 3.3 Functional Outline of Circuit Cards 3.3.1 Control Circuit Card Table 2-4 shows the functional outline of each control circuit card. Table 2-3 Functional Outline of Installation Hardware INSTALLATION HARDWAREFUNCTIONAL NAMEFUNCTIONAL OUTLINE SN1225 BASE-A BASEBase Unit (includes Top Cover) The Base Unit and Top Cover is required for PIM. RACK PARTS RACK PARTSMounting Brackets (RACK PARTS) The RACK PARTS are sets of hardware for floor standing and wall mount, which will be installed at the rear side of PIM. The RACK PARTS must be installed, when the system is 3 modules. COVER PARTS (B)TOP BOTTOM COVERBottom Cover (includes Top Cover) The Bottom Cover and Top Cover is used when using 19-inch Rack mount- ing and Desk Top installation. One sets of Bottom Cover and 4-Rubber Foots are required for Desk Top in- stallation with PIM. 19” BRACKET (F)19” BRACKET(F)19-inch Bracket The 19-inch Bracket is sets of hardware to mount the PIM, MDFM and/or BATTM in the IEC standard 19-inch rack. One set of 19-inch Bracket is re- quired for the PIM. Table 2-4 Functional Outline of Control Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE PN-CP03 MPMain Processor card. This card is equipped with Memory, TDSW (1024CH ´ 1024CH), 16-Line CFT, DTMF Sender, Clock, PLO (receiver mode 2 ports), RS-232C Ports (2 ports) for MAT/Built-in SMDR, Modem for remote maintenance, and Mu- sic-On-Hold tone source (Melody IC/TNT), 4-circuit PBR (for PB calling or DID). This card is used on the basis of one per system. PZ-PW86 PWRMain power supply card. Input: AC 120 V/240 V (50 Hz/60 Hz) [with 110 V option] Output: –27 V (4.5 A), +5 V (7.5 A), +90 V (110 mA), CR (30 mA) One card is mounted in PIM. Note :This card does not provide Ring Generator or Message Wait volt- age.
ND-46551 (E) CHAPTER 2 Page 11 Revision 2.0 3.3.2 Application Circuit Cards Table 2-5 shows the functional outline of each application circuit card. Table 2-5 Functional Outline of Application Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE PN-AP00-A AP00Application Processor card. This card is equipped with four RS-232C ports, and is used for SMDR, H/M Printer, PMS functions and MCI. This card is used on the basis of one per system. PN-AP01 AP01Application Processor card. This card is equipped with one RS-232C port and one Ethernet interface port, and is used for OAI function. Also, this card is used to expand authorization code and ACD. This card is used on the basis of one per system. PN-BRTA BRIBasic Rate (2B+D) Interface Trunk card. (S/T Interface) This card has one circuit of Basic Rate interface and provides one 2-channel PCM dig- ital line. PN-ME00 EXTMEMMemory Expansion card. This card is used with PN-AP00-A card for providing expansion memory. This card can be equipped with an expansions SRAM card (1MB) as SMDR data mem- ory. PN-CC00 ETHEREthernet Control card. This card is used with the PN-AP01 card to accommodate the Ethernet, transmitting/re- ceiving a signal of TCP/IP protocol. PN-CK00 PLOPhase Locked Oscillator card. This card is a phase locked oscillator for providing a synchronized clock signal with the network. This card is used when the PBX is a master office or when the PBX requires two clock supply routes and those frequencies differ. PN-24DTA/ PN-24DTA-ADTIDigital Trunk Interface (23B+D, 1.5 Mbps) card. This card accommodates 24-channel, PCM digital lines. PN-4RSTB MFR4-line MF Receiver Trunk card. This card is used for MF Signaling on Digital DID trunks. A maximum of four cards can be provided per one system, including the PN-4RSTC card. PN-4RSTC CIR4-line CALLER ID Receiver Trunk card. This card is used for CALLER ID (CLASS SM) on analog trunks. A maximum of four cards can be provided per one system, including the PN-4RSTB card. PN-SC00 CCHCommon Channel Handler card. This card transmits/receives signals on the common signaling channel of No. 7 CCIS. PN-SC01 DCHD-channel Handler card. This card transmits/receives signals on the D channel of ISDN Primary Rate (23B+D). PN-SC02 ICHISDN-channel Handler card. This card provides the D channel signaling interface and controls an ILC (Layer 2 and 3).
CHAPTER 2 ND -4 6551 ( E) 3.3 .3 Lin e/T run k Ci rc ui t C ards
CHAPTER 2 ND -4 6551 ( E) Tab le 2-7 L ine Con diti o n of E ach T er mina ls
ND -4 6551 ( E) CHAPTER 2 *Th e v alue in th e [ ] s ho ws th e ca ble le ng th wh en usin g th e long li ne fun ction.
CHAPTER 2 ND-46551 (E) Pag e 1 6 Revision 2.0 4. CIRCUIT CARD INSTALLATION CONDITIONS 4.1 Circuit Card Mounting Slots Figure 2-6 below shows circuit card mounting slots allocated in the PIM, on the basis of circuit card type. Figure 2-6 Circuit Card Mounting Slots LT00 - LT10 : Line/trunk circuit card mounting slots • LT00 - LT08 : All of line/trunk circuit card can be mounted in these slots • LT09 : All of line/trunk circuit card can be mounted in this slot (But a maximum of 4 circuits can be assigned for the circuit card with cabling.) • LT10 : Line/trunk circuit card with cabling can not be mounted in this slot, since this slot has no connection to the MDF via the backplane. AP0 - AP5 : Application circuit card mounting slots MP : PN-CP03 mounting slot PWR : PZ-PW86 mounting slot *1Either line/trunk circuit cards or application circuit cards can be mounted in these slots. *2When mounting the circuit card with cabling in LT08 slot and LT09 slot, the circuit card must be mounted with the following conditions. (1)When mounting PN-8LC/PN-8DLC card in LT08 slot, the circuit card with cabling can not be mounted in LT09 slot. (2)When mounting line/trunk circuit card in LT09 slot, a maximum of 4 circuits can be assigned for the circuit card. LT09/AP3LT08/AP2LT07/AP1 LTC1LTC0LTC2 BWB P W R LT10/AP4LT00LT01LT02LT03LT04LT05LT06/AP0AP5MP PIM *1 *2
ND-46551 (E) CHAPTER 2 Page 17 Revision 2.0 4.2 Installation Conditions (1) The application circuit cards PN-BRTA and PN-24DTA-A cannot be mounted in slots AP4 or AP5, since neither of these slots has a connection to the MDF via the backplane. (2) The application circuit card type PN-CC00 can be mounted in any LT/AP slot, but it occupies two slot po- sitions; i.e. the slot immediately to its right must be vacant. (3) The PN-PW00 can be mounted in any LT/AP slot, but it occupies two slot positions; i.e. the slot immedi- ately to it’s left must be vacant. Note :The PN-CC00 must be mounted adjacent to its related PN-AP01 card, in order to allow the connection of cable type 48-TW-0.3 CONN CA between these cards.