    							ND-46551 (E) CHAPTER 3
    Page 49
    Revision 2.0
    NAP-200-003
    Sheet 19/21
    Installation of Main Equipment
    (2) Connect the RACK PARTS to each other.
    Note :This installation procedure is required when the system is 3 modules (PIM + MDFM + BATTM).
    Figure 003-17  Connection of RACK PARTS
    RACK PARTS
    REAR
    RACK PARTS
    BASE 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 5 0
    Revision 2.0
    NAP-200-003
    Sheet 20/21
    Installation of Main Equipment
    (3) Connect the PIM to the RACK PARTS using the 4 screws provided with the RACK PARTS.
    Note :This installation procedure is required when the system is 3 modules (PIM + MDFM + BATTM).
    Figure 003-18  Connection of the PIM and the RACK PARTS
    REAR
    PIM  Note
    BASE
    Note :The BATTM and the MDFM can be installed in the same manner as the PIM. 
    						
    							ND -4 6551 ( E)  CHAPTER 3
    NAP-200-0 03
    MD FMN ote 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 5 2
    Revision 2.0
    NAP-200-004
    Sheet 1/5
    Connection of Battery
    1. BATTERY CONNECTION
    CAUTION 1:24V batteries must be used in this system.
    CAUTION 2:If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ-
    PW86 card, the PZ-PW86 card or the BWB may be broken. Therefore, the installer must per-
    form work in accordance with the following steps when mounting or removing the batteries.
    • When mounting batteries:
    (1) Connect the battery cable to the batteries.
    (2) Mount the batteries into the appointed position of the PIM or the BATTM.
    (3) Connect the battery cable to the PZ-PW86 card.
    • When removing batteries:
    (1) Disconnect the battery cable from the PZ-PW86 card.
    (2) Remove the batteries from the PIM or the BATTM.
    Recommended Battery
    Internal Battery : YUASA
    MATUSHITAtype
    typeNPH-3.2-12
    LCR-12V-3.4NE
    External Battery : YUASA
    MATUSHITAtype
    typeNP-24-12B
    LCL-12V-24 
    						
    							ND-46551 (E) CHAPTER 3
    Page 53
    Revision 2.0
    NAP-200-004
    Sheet 2/5
    Connection of Battery
    CAUTION 3:Battery Replacement Table and Battery Warnings
    The label, which shows battery replacement table and battery warnings, is attached to the re-
    verse side of Front Cover for PIM and BATTM.
    During the battery installation process, always observe the warning statements. When replacing
    batteries, adhere to the battery replacement table to increase battery life and to insure safe op-
    eration.
    25° C ~ 30° C
    2.0 ~ 2.5(77° C ~ 86° F)
    
    
     
    
    
    
    
     
    
    
    
    
    
    
    
    
    
    
    
    
    
    \
     \
    
    \
    
    \
    
    \
    
    \
    
    \
    
    \
    
    
     
    
    
    
     
    
    
    
     
    
    
    
    
    
     
    
    
    
    
     
    
    
    LABEL PIM/BATTM
    FRONT COVER
    BATTERY REPLACEMENT TABLE
    INSTALLATION DATE:
    AMBIENT 
    TEMPERATURE25° C(77° F)
    REPLACEMENT
    INTERVAL2.5 ~ 3.0 1.5 ~ 2.0
    CAUTIONTO PREVENT INJURY AND SKIN BURN,
    PAY ATTENTION TO THE FOLLOWING.
    o DO NOT STRIKE A MATCH OR CAUSE A SPARK IN
    VICINITY OF BATTERY.
    o PLACE THE EQUIPMENT WELL VENTILATED 
    AREA.
    o DO NOT SHORT.
    o REPLACE BATTERY ONLY AFTER BATTERY 
    GASES HAVE BEEN DISPERSED.
    o ELECTROLYTE LEAKAGE OR OTHER HAZARDS
    MAY RESULT IF THE BATTERY IS NOT REPLACED
    IN ACCORDANCE WITH THE SPECIFIED INTER-
    VALS.
      
    (86° C ~ 104° F)30° C ~ 40° C
     YEARS YEARS YEARS 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 5 4
    Revision 2.0
    NAP-200-004
    Sheet 3/5
    Connection of Battery
    1.1 Internal Battery Connection
    (1) Mount the battery unit (24 V DC, 3.4 AH) into the PIM.
    Figure 004-1  Internal Battery Mounting
    FRONT 67mmDIMENSION OF BATTERY
    BATTERY UNIT
    (24V DC, 3.4AH)
    (LOCALLY PROVIDED)
    (2.6 inch)
    134mm
    (5.3 inch) 60mm
    (2.4 inch)
    PIM
    BASE 
    						
    							ND -4 6551 ( E)  CHAPTER 3
    NAP-200-0 04
    P LUG IN  TO B ATT  1
    BASE 
    						
    							CHAPTER 3  ND -4 6551 ( E)
    NAP-2 00-0 04
    T O PZ -PW 86 IN P IM 
    						
    							ND -4 6551 ( E)  CHAPTER 3
    NAP-200-005
    T O PIM
    TWI STE D 25  PA IR CAB LES
    TO  MDF 
    						
    							CHAPTER 3 ND-46551 (E)
    Pag e 5 8
    Revision 2.0
    NAP-200-005
    Sheet 2/5
    Cable Running to the MDF
    2. INSTALLATION OF EXTERNAL MDF
    • Secure the external MDF onto the floor or mount the MDF onto the wall.
    • Mount the required MDF components.
    • If required, install the cable ducts for the cables to be laid between the MDF and the Main Equipment. In
    this case, confirm the locations of the cable holes for the Main Equipment. See Figure 005-2.
    Figure 005-2  Cable Hole Location
    FRONT
    430 mm (16.9 inch)
    RACK PARTS
    214 mm (8.4 inch)
    184 mm (7.2 inch)30 mm (1.2 inch) CABLE HOLE 
    						
    All NEC manuals Comments (0)