Page 121

CHAPTER 2 ND-45670 (E)
Pag e 1 04
Revision 2.0
AUTOMATIC CAMP-ON
PROGRAMMING
DESCRIPTION DATA
Specify the Camp-On Tone pattern. (1) 068
(2) 0/1 : Sent out once/Sent out periodi-
cally (4- intervals)
Assign Automatic Camp-On to the required 
DIT Trunks.• YY = 13 (In Day mode)
• YY = 14 (In Night mode)
(1) Trunk No. (000-255)
(2) 06: Automatic Camp-OnCM08 START
END
CM30 

Page 122

ND-45670 (E) CHAPTER 2
Page 105
Revision 2.0
AUTOMATIC NUMBER IDENTIFICATION (ANI) 
(1300 Series Enhancement)
PROGRAMMING
1. DTI Assignment for ANI
DESCRIPTION DATA
Assign a trunk Route Number to each DTI. • YY=00 
(1) Trunk No. (000-255) 
(2) Trunk Route No. (00-63)
Specify the Terminating System in Day Mode 
and Night Mode for incoming calls.• YY=02 (Day Mode) 
• YY=03 (Night Mode) 
(1) Trunk No. (000-255) 
(2) 31 : DID, TIE and any call which is not 
handled by the PBX
Assign the trunk Route data to...

Page 123

CHAPTER 2 ND-45670 (E)
Page 106 Addendum-001
Revision 2.1 JULY, 1998
AUTOMATIC NUMBER IDENTIFICATION (ANI)
(1300 Series Enhancement)
DESCRIPTION DATA
T/R : Transmitter PAD/Receiver PAD
+:Gain
- : Loss• YY=19 (DTI Pad) 
(1) Trunk Route No. (00-63) 
(2) 0 :
1 : Programmable PAD (See CM42)
2: 
3: 
4: 
5 :  Fixed PAD (See left table) 
6:
7:
• YY=20 (Sender Start Condition) 
(1) Trunk Route No. (00-63) 
(2) 00: Wink Start
Assign calling number sending method from 
the network to each trunk route.• YYY=129...

Page 124

ND-45670 (E) CHAPTER 2
Addendum-001 Page 107
JULY, 1998 Revision 2.1
AUTOMATIC NUMBER IDENTIFICATION (ANI)
(1300 Series Enhancement)
2. MF Signaling Assignment
DESCRIPTION DATA
Assign a slot number to MF Receiver Trunk.
Note:The SENSE switch on the MF
Receiver Trunk gives the slot number.(1) Slot No. (04-15) 
(2) 08: MF Receiver Trunk (PN-4RST)
Assign MF Receiver Trunk Number to each 
MF Receiver Trunk.• YY=04 
(1) XX: MF Receiver Trunk No. (00-15) 
(2) XX
X 
Slot No. assigned by CM05
Circuit No. (0-3)...

Page 125

CHAPTER 2 ND-45670 (E)
Pag e 1 08
Revision 2.0
AUTOMATIC NUMBER IDENTIFICATION (ANI 
1300 Series Enhancement)
DESCRIPTION DATA
Assign MF Receiver sensitive level. • Y=1 
(1) 1 (MF Receiver Sensitive level) 
(2) 00: –21 dBm 
14: –35 dBm 
15 : –36 dBm
(–1 dBm increments)
Assign MF Receiver to each circuit number 
(0-3) of the MF Receiver Trunk.
Note:AP Numbers 0-3 correspond to the
Slot Numbers assigned by CM05 (00-
15): 
AP Number 0: Slot Number X 
AP Number 1: Slot Number Y
AP Number 2: Slot Number Z 
AP...

Page 126

ND-45670 (E) CHAPTER 2
Page 109
Revision 2.0
AUTOMATIC NUMBER IDENTIFICATION (ANI 
1300 Series Enhancement)
3. ANI Assignment
DESCRIPTION DATA
Assign requiring of ANI Signal from T1 
network when an incoming call terminates.(1) 472 
(2) 0: Available
Assign the Signal Pattern received from T1 
network.
• When the Signal Pattern from T1 network 
is FGD-Format: Assign the data to 
“NONE”. 
• When the Signal Pattern from T1 network 
is ANI-Format: Assign the data to 
“02”.
Note
•Y=3 
(1) 00 (Signal Pattern...

Page 127

CHAPTER 2 ND-45670 (E)
Pag e 1 10
Revision 2.0
AUTOMATIC NUMBER IDENTIFICATION (ANI 
1300 Series Enhancement)
DESCRIPTION DATA
Assign the ACK-WINK Signal to be sent to the 
DTI when the signal kind of Called Number 
received from T1 network is DP Signal.
Note:
• When the Signal Pattern from T1 network 
is FGD-Format: Assign the data to “1”. 
• When the Signal Pattern from T1 network 
is ANI-Format: Assign the data to “0”.•Y=A 
(1) 18 (Sending of ACK-WINK Signal on Re-
ceiving DP Signal)    
Note
(2) 0:...

Page 128

ND-45670 (E) CHAPTER 2
Page 111
Revision 2.0
AUTOMATIC NUMBER IDENTIFICATION (ANI 
1300 Series Enhancement)
When the signal pattern of the Called Number sent from T1 network is as shown below, assign the following data,
if required.
Called Number = NPA + NNX + Called Station Number
Note:
FGD-Format and ANI-Format are:
HARDWARE REQUIRED
PN-24DTA card
PN-4RST card
DESCRIPTION DATA
Assign the Digit Addition/Deletion on the 
incoming calls.•
(1)
(2)YY=17 (Digit Addition/Deletion Assign-
ment) 
Trunk Route...

Page 129

CHAPTER 2 ND-45670 (E)
Pag e 1 12
Revision 2.0
AUTOMATIC RECALL
PROGRAMMING
DESCRIPTION DATA
Specify the timing for AUTOMATIC 
RECALL. If no data is set, the following 
Automatic Recall timing is applied:
Attendant Recall - 31.2-33.6 seconds
Non exclusive Hold - 60-64 seconds
Exclusive Hold - 236-240 seconds
Transfer Recall - 24-28 seconds
Attendant Hold Recall - 31.2-33.6 seconds
Camp-On Recall - 24-32 seconds•  Y = 0
(1)  00: Attendant Recall
(2)  01-24: 2.4-124.8 sec. (Increments 01-14
are 2.4-sec....

Page 130

ND-45670 (E) CHAPTER 2
Page 113
Revision 2.0
BACKGROUND MUSIC (BGM)
PROGRAMMING
DESCRIPTION DATA
Assign BGM Interface Trunks (PN-4COT/
PN-TNT) to the required LENs.
Note:The PN-TNT Circuit No. must be
assigned to the first LEN (Level 0)
and/or the third LEN (Level 2) of
each LT slot.(1)  XXXX: 0000-0511 (LEN No. )
(2) D000-D255: PN-4COT/PN-TNT Circuit
No.
Assign the Service Restriction Class (A) to the 
required Multiline Terminals.• YY = 02
(1)  X-XXXX:Primary Extension No. of the
Multiline Terminal
(2)...