Page 91

CHAPTER 2 ND-45670 (E)
Page 74 Addendum-002
Revision 2.2 JANUARY, 1999
ATTENDANT CONSOLE (SN716 DESKCON)
DESCRIPTION DATA
Specify the type of the Attendant Console.  •  YY=22
(1) ATTCON No. (0-7)
(2)  0 : SN716 DESKCON
1 : SN610 ATTCON
Allocate the ATT Group No. to each SN716
DESKCON.• YY=00
(1) ATTCON No. (0-7)
(2)  0: ATT GROUP 0
3: ATT GROUP 3
Specify the Master SN716 DESKCON within
the ATT Group assigned by YY=00. • YY=01
(1) ATTCON No. (0-7) 
(2) 0/1 : Master/Sub
When providing 2nd Ringing feature...

Page 92

ND-45670 (E) CHAPTER 2
Page 75
Revision 2.0
ATTENDANT DELAY ANNOUNCEMENT
PROGRAMMING
DESCRIPTION DATA
Assign a Digital Announcement Trunk Circuit 
No. to the required LEN.
Note:The Digital Announcement Trunk
Circuit No. must be assigned to the
first LEN (Level 0) and/or the third
LEN (Level 2) of each LT slot. (1)  LEN (0000-0511)
 (2)  EB000-EB127: Digital Announcement 
Trunk Circuit No. 
For PIM0/1: EB000-EB031
For PIM2/3: EB032-EB063
For PIM4/5: EB064-EB095
For PIM6/7: EB096-EB127
Provide the...

Page 93

CHAPTER 2 ND-45670 (E)
Pag e 7 6
Revision 2.0
ATTENDANT DELAY ANNOUNCEMENT
DESCRIPTION DATA
Specify the replaying of the message recorded 
in the Digital Announcement Trunk.(1) 165
(2) 0 : The message is replayed at an in-
terval assigned by CM41 Y= 0, 
Function No. 47.
1 : The message is played only once.
To record, replay, and delete a message, assign 
the Digital Announcement Trunk access 
codes, respectively. • Y = 0-3 (Numbering Plan Group 0-3)
(1) X-XXX: Access Code
(2) A00: Record
A01: Replay
A02:...

Page 94

ND-45670 (E) CHAPTER 2
Page 77
Revision 2.0
ATTENDANT OVERFLOW
PROGRAMMING
Note:Refer to the Automated Attendant feature programming section in this manual for assignment information
of the Automated Attendant when using the Automated Attendant as the Attendant Overflow destination.
DESCRIPTION DATA
Provide the system with ATTENDANT 
OVERFLOW.(1) 067
(2) 0: Available
Assign the data for terminating system in Day/
Night Mode for each trunk.• YY = 02 (Day Mode)
(1) Trunk No. (000-255)
(2) 14: Termination...

Page 95

CHAPTER 2 ND-45670 (E)
Pag e 7 8
Revision 2.0
ATTENDANT OVERRIDE
PROGRAMMING
DESCRIPTION DATA
Provide the system with ATTENDANT 
OVERRIDE.(1) 012
(2) 1 : Available
Specify the interval of the Warning Tone sent 
to the connected parties.(1) 045
(2) 0 : Only Once
1
 : Every 4 sec.
Specify whether the Warning Tone is sent to 
the outside party.(1) 076
(2) 0 : To be sent out.
1
 : Not to be sent out.
Assign Service Restriction Class (A) to each 
station.• YY = 02
(1) X-XXXX (Station No.)
(2) XX
 XX
*a:...

Page 96

ND-45670 (E) CHAPTER 2
Page 79
Revision 2.0
ATTENDANT OVERRIDE
Note:This feature cannot be used in conjunction with Attendant Lockout.
DESCRIPTION DATA
Assign the BV key to SN610 Attendant 
Console.
Note:By Resident System Program, one of
the Multi-Function keys is assigned
as a BV key (when receiving Busy
Tone).• YY = 00
(1) ATTCON No. +   + Key No. 
(2) F6107: Busy Verification
CM90
END
A
, 

Page 97

CHAPTER 2 ND-45670 (E)
Pag e 8 0
Revision 2.0
AUTHORIZATION CODE
PROGRAMMING
1. In a system with an Application Processor (PN-AP01) 
DESCRIPTION DATA
Assign a slot number to the PN-AP01 card 
according to the location of the card. 
Note:The slot number is given by the
SENSE switch on the PN-AP01 card.(1) Slot Number (04-15)
(2) 07: PN-AP01 card
Designate the AP card for this feature.(1) 216: Designates the Processor for the 
Authorization Code.
(2) 1 : AP (PN-AP01)
Specify whether Service Set Tone should...

Page 98

ND-45670 (E) CHAPTER 2
Page 81
Revision 2.0
AUTHORIZATION CODE
DESCRIPTION DATA
Assign the access code for each Authorization 
Code.• Y = 0-3 (Numbering Plan Group 0-3)
(1) X-XXX: Access Code
(2) 086: Authorization Code
Specify the maximum number of digits for 
each Authorization Code.(1) 11: Authorization Code Max. digits
(2) Max. number of digits (01-10 ). 
If Check Code is provided, the maximum 
number of digits is limited to eight (8).
Note:CMD6 must be completed prior to
programming CMD5.
Set the...

Page 99

CHAPTER 2 ND-45670 (E)
Pag e 8 2
Revision 2.0
AUTHORIZATION CODE
DESCRIPTION DATA
Specify the conditions for adding a Check 
Code to each Authorization Code.
A Check Code consists of 2 digits:
The 1st and 2nd Check Code are generated by 
the AP according to the conditions specified 
by Y = 0 and Y = 1.
Authorization Code:
X
1 X2 X3 X4 X5 X6 X7 X8 C1 C2
 • Y = 0 (Designation of Significant digits 
for Check Code generation)
(1) 0: For 1st Check Code
1: For 2nd Check Code
(2) 00 X
 X: Significant digit...

Page 100

ND-45670 (E) CHAPTER 2
Page 83
Revision 2.0
AUTHORIZATION CODE
Note 1:Up to 1,000 Authorization codes combined with Forced Account Codes and Direct Inward System Access
(DISA) codes can be defined.
Note 2:When deleting all ID codes stored in the PN-AP01 card at one time, do the following operation:
 + D60 +   + 0000 +   + CCC +   
Note 3:When providing Mask Data for Authorization Codes, assign CMD001-160-175 (Refer to the SMDR System
Manual).
DESCRIPTION DATA
Set the Authorization Code and its temporary...