Page 91
CHAPTER 2 ND-45670 (E) Page 74 Addendum-002 Revision 2.2 JANUARY, 1999 ATTENDANT CONSOLE (SN716 DESKCON) DESCRIPTION DATA Specify the type of the Attendant Console. • YY=22 (1) ATTCON No. (0-7) (2) 0 : SN716 DESKCON 1 : SN610 ATTCON Allocate the ATT Group No. to each SN716 DESKCON.• YY=00 (1) ATTCON No. (0-7) (2) 0: ATT GROUP 0 3: ATT GROUP 3 Specify the Master SN716 DESKCON within the ATT Group assigned by YY=00. • YY=01 (1) ATTCON No. (0-7) (2) 0/1 : Master/Sub When providing 2nd Ringing feature...
Page 92
ND-45670 (E) CHAPTER 2 Page 75 Revision 2.0 ATTENDANT DELAY ANNOUNCEMENT PROGRAMMING DESCRIPTION DATA Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note:The Digital Announcement Trunk Circuit No. must be assigned to the first LEN (Level 0) and/or the third LEN (Level 2) of each LT slot. (1) LEN (0000-0511) (2) EB000-EB127: Digital Announcement Trunk Circuit No. For PIM0/1: EB000-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 Provide the...
Page 93
CHAPTER 2 ND-45670 (E) Pag e 7 6 Revision 2.0 ATTENDANT DELAY ANNOUNCEMENT DESCRIPTION DATA Specify the replaying of the message recorded in the Digital Announcement Trunk.(1) 165 (2) 0 : The message is replayed at an in- terval assigned by CM41 Y= 0, Function No. 47. 1 : The message is played only once. To record, replay, and delete a message, assign the Digital Announcement Trunk access codes, respectively. • Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) A00: Record A01: Replay A02:...
Page 94
ND-45670 (E) CHAPTER 2 Page 77 Revision 2.0 ATTENDANT OVERFLOW PROGRAMMING Note:Refer to the Automated Attendant feature programming section in this manual for assignment information of the Automated Attendant when using the Automated Attendant as the Attendant Overflow destination. DESCRIPTION DATA Provide the system with ATTENDANT OVERFLOW.(1) 067 (2) 0: Available Assign the data for terminating system in Day/ Night Mode for each trunk.• YY = 02 (Day Mode) (1) Trunk No. (000-255) (2) 14: Termination...
Page 95
CHAPTER 2 ND-45670 (E) Pag e 7 8 Revision 2.0 ATTENDANT OVERRIDE PROGRAMMING DESCRIPTION DATA Provide the system with ATTENDANT OVERRIDE.(1) 012 (2) 1 : Available Specify the interval of the Warning Tone sent to the connected parties.(1) 045 (2) 0 : Only Once 1 : Every 4 sec. Specify whether the Warning Tone is sent to the outside party.(1) 076 (2) 0 : To be sent out. 1 : Not to be sent out. Assign Service Restriction Class (A) to each station.• YY = 02 (1) X-XXXX (Station No.) (2) XX XX *a:...
Page 96
ND-45670 (E) CHAPTER 2 Page 79 Revision 2.0 ATTENDANT OVERRIDE Note:This feature cannot be used in conjunction with Attendant Lockout. DESCRIPTION DATA Assign the BV key to SN610 Attendant Console. Note:By Resident System Program, one of the Multi-Function keys is assigned as a BV key (when receiving Busy Tone).• YY = 00 (1) ATTCON No. + + Key No. (2) F6107: Busy Verification CM90 END A ,
Page 97
CHAPTER 2 ND-45670 (E) Pag e 8 0 Revision 2.0 AUTHORIZATION CODE PROGRAMMING 1. In a system with an Application Processor (PN-AP01) DESCRIPTION DATA Assign a slot number to the PN-AP01 card according to the location of the card. Note:The slot number is given by the SENSE switch on the PN-AP01 card.(1) Slot Number (04-15) (2) 07: PN-AP01 card Designate the AP card for this feature.(1) 216: Designates the Processor for the Authorization Code. (2) 1 : AP (PN-AP01) Specify whether Service Set Tone should...
Page 98
ND-45670 (E) CHAPTER 2 Page 81 Revision 2.0 AUTHORIZATION CODE DESCRIPTION DATA Assign the access code for each Authorization Code.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (2) 086: Authorization Code Specify the maximum number of digits for each Authorization Code.(1) 11: Authorization Code Max. digits (2) Max. number of digits (01-10 ). If Check Code is provided, the maximum number of digits is limited to eight (8). Note:CMD6 must be completed prior to programming CMD5. Set the...
Page 99
CHAPTER 2 ND-45670 (E) Pag e 8 2 Revision 2.0 AUTHORIZATION CODE DESCRIPTION DATA Specify the conditions for adding a Check Code to each Authorization Code. A Check Code consists of 2 digits: The 1st and 2nd Check Code are generated by the AP according to the conditions specified by Y = 0 and Y = 1. Authorization Code: X 1 X2 X3 X4 X5 X6 X7 X8 C1 C2 • Y = 0 (Designation of Significant digits for Check Code generation) (1) 0: For 1st Check Code 1: For 2nd Check Code (2) 00 X X: Significant digit...
Page 100
ND-45670 (E) CHAPTER 2 Page 83 Revision 2.0 AUTHORIZATION CODE Note 1:Up to 1,000 Authorization codes combined with Forced Account Codes and Direct Inward System Access (DISA) codes can be defined. Note 2:When deleting all ID codes stored in the PN-AP01 card at one time, do the following operation: + D60 + + 0000 + + CCC + Note 3:When providing Mask Data for Authorization Codes, assign CMD001-160-175 (Refer to the SMDR System Manual). DESCRIPTION DATA Set the Authorization Code and its temporary...