Page 101
CHAPTER 2 ND-45670 (E) Pag e 8 4 Revision 2.0 AUTHORIZATION CODE 2. In a system without an Application Processor (PN-AP01) DESCRIPTION DATA Designate the MP card for this feature. (1) 216: Designation of Processor for Au- thorization Code (2) 0: MP (PN-CP00) card Specify whether Service Set Tone should be provided after dialing the access code for Authorization Code.(1) 362: Provision of Service Set Tone af- ter dialing the access code. (2) 0/1 : Not to be provided/To be provid- ed Assign the Class of...
Page 102
ND-45670 (E) CHAPTER 2 Page 85 Revision 2.0 AUTHORIZATION CODE Note:Up to 100 Authorization Codes combined with Forced Account Codes can be defined. DESCRIPTION DATA Define the purpose (Y = 1) and the temporary Class of Service (Y = 2-4) for each Authorization Code.• Y = 1 (Purpose of the Code) (1) XX: Code Serial No. (00-99) (2) 1: Authorization Code • Y = 2 (Trunk Restriction Class) (1) XX : Code Serial No. (00-99) (2) X : Trunk Restriction Class (1-8) specified by CM35 YY = 51-68. • Y = 3 [Service...
Page 103
CHAPTER 2 ND-45670 (E) Page 86 Addendum-002 Revision 2.2 JANUARY, 1999 AUTOMATED ATTENDANT PROGRAMMING DESCRIPTION DATA Assign the data for Automated Attendant to the required trunks. Note: When providing a Night Message for Automated Attendant, the 2nd An- swering Message which is assigned by CM49 YY=00, 2nd data 02XX is used for the Night Message. In that case, the 2nd data 08 of CM30 YY=30, 31 cannot be specified for handling of Busy/Not Available Auto- mated Attendant destination.• YY=02...
Page 104
ND-45670 (E) CHAPTER 2 Addendum-002 Page 87 JANUARY, 1999 Revision 2.2 AUTOMATED ATTENDANT DESCRIPTION DATA • YY=33 (When YY=30, 31 is set to data 08, and all DTMF Receivers are busy.) (1) Trunk No. (000-255) (2) 00 : Disconnection 01 : Forwarded to TAS Indicator 03 : Forwarded to SN610 ATTCON 15 : Disconnection Assign the DTMF Receiver for only Automat- ed Attendant, if desired.•Y=2 (1) XX X: DTMF Receiver No. Card No. 00-15 assigned by CM10 (E200-E215) Circuit No. (0-3) (2) 0: Only for Automated...
Page 105
CHAPTER 2 ND-45670 (E) Page 88 Addendum-002 Revision 2.2 JANUARY, 1999 AUTOMATED ATTENDANT DESCRIPTION DATA Specify whether no Dial tone connection is re- quired for the answering method assigned by CM64 Y=0.•Y=2 (1) 06 (2) 0/1 : Without DT/With DT Specify the ringing rate for an Automated At- tendant Call.(1) 180 (2) 0/1 : 0.2 sec. ON-0.2 sec. OFF 0.2 sec. ON-0.2 sec. OFF 0.2 sec. ON-2 sec. OFF /As per CM35 YY=33 Specify the process when a call is transferred by an Automated Attendant to a predeter-...
Page 106
ND-45670 (E) CHAPTER 2 Addendum-002 Page 89 JANUARY, 1999 Revision 2.2 AUTOMATED ATTENDANT When the 1st and/or 2nd answering message is required: CM30 YY=30, 31, 2nd data 08/CM64 Y=0, 2nd data 02, or Night Message is required: CM64 Y=2, 2nd data 02, do the following programming. The following steps are al- ways required. HARDWARE REQUIRED For providing the first and/or second Answering Message/Night Message, Digital Announcement Trunk (PN- 2DATA) is required. DESCRIPTION DATA Assign a Digital...
Page 107
CHAPTER 2 ND-45670 (E) Pag e 9 0 Revision 2.0 AUTOMATIC CALL DISTRIBUTION (ACD) PROGRAMMING To activate ACD: DESCRIPTION DATA For each ACD Group, assign station numbers, one by one, in the order of hunting. Note:Up to 60 stations can be assigned into a single ACD group. Example:For setting Station Numbers 200, 201, 202 into one ACD Group. 1st Operation (1) 200 (2) 201 2nd Operation (1) 201 (2) 202 3rd Operation (1) 202 (2) 200•Y = 0 (1) X-XXXX (Station No.) (2) X-XXXX (Another Station No. to be...
Page 108
ND-45670 (E) CHAPTER 2 Page 91 Revision 2.0 AUTOMATIC CALL DISTRIBUTION (ACD) DESCRIPTION DATA • Y = 6 (Tie Line Incoming Call) (1) X-XXXX (Pilot Station No. of the ACD Group) (2) 0/1 : Not to be provided/To be provid- ed • Y = 7 (DID Call) (1) X-XXXX (Pilot Station No. of the ACD Group) (2) 0/1 :Not to be provided/To be provid- ed • Y=B (Designation of the number of queuing in each ACD group) (1) X-XXXX (Pilot Station No. of the ACD Group) (2) 0/1 : To be provided (See CM42-16)/ Not to be provided...
Page 109
CHAPTER 2 ND-45670 (E) Pag e 9 2 Revision 2.0 AUTOMATIC CALL DISTRIBUTION (ACD) DESCRIPTION DATA Assign the ACD Busy-Out key on the Multiline Terminal, if required.• YY = 00 (1) Primary Extension No. + + Key No. (2) F0044: ACD Busy-Out Assign the Release key on the Multiline Terminal, if required.• YY = 00 (1) Primary Extension No. + + Key No. (2) F1020: Release Specify the processing for an incoming call when all ACD Stations are busy.(1) 212 (2) 0/1 : Busy Tone Connection/Queuing Specify the...
Page 110
ND-45670 (E) CHAPTER 2 Page 93 Revision 2.0 AUTOMATIC CALL DISTRIBUTION (ACD) To provide ACD delay announcement: DESCRIPTION DATA Assign the Class of Service for Digital Announcement Trunk Access (Record/ Replay/Delete) to the required station.• CM12 YY=02 (1) X-XXXX: Station No. (2) XX XX *a *a: Service Restriction Class (A) (00-15 ) • CM15 YY=33 (1) XX: Service Restriction Class (A) as- signed by CM12 YY=02 (2) 1 : Allowed Assign the Digital Announcement Trunk Circuit No. to the required LEN....