CHAPTER 2 ND-45670 (E) Pag e 1 34 Revision 2.0 CALL FORWARDING: CALL FORWARDING-NO ANSWER DESCRIPTION DATA To apply this feature to incoming calls, set the trunk route combinations for Tandem Connection. Note:For Resident System Programming, refer to the Command Manual.• CM35 YY=05 (1) Trunk Route No. (00-63) Note (2) 1 : Release Signal arriveNote • CM36 (1) Incoming Trunk Route No. + Outgoing Trunk Route No. (Assigned by CM35 YY=05) (2) 0: Allowed Specify the setting method for Call Forwarding-No...
Page 152
ND-45670 (E) CHAPTER 2 Page 135 Revision 2.0 CALL FORWARDING: CALL FORWARDING-DESTINATION PROGRAMMING DESCRIPTION DATA Assign Service Restriction Class (A) to each station.• YY = 02 (1) X-XXXX: (Station No.) (2) XX XX *a: Service Restriction Class (A) (00-15 ) Assign this feature to Service Restriction Class (A) assigned by CM12 YY=02.•Y=15 (1) XX: Service Restriction Class (A) as- signed by CM12 YY=02. (2) 1 : Allowed Assign the access code for Call Forwarding- Destination, Entry and Cancellation,...
Page 153
CHAPTER 2 ND-45670 (E) Pag e 1 36 Revision 2.0 CALL FORWARDING: MULTIPLE CALL FORWARDING-ALL CALLS PROGRAMMING In addition to the programming for Call Forwarding-All Calls, do the following programming. DESCRIPTION DATA Specify the number of times a call can be call forwarded.(1) 14 (2) 01-05 [Number of times (One to five times)] If no data is set, the default setting is 5.CM42 END START
Page 154
ND-45670 (E) CHAPTER 2 Page 137 Revision 2.0 CALL FORWARDING: MULTIPLE CALL FORWARDING-BUSY LINE PROGRAMMING In addition to the programming for Call Forwarding-Busy Line, do the following programming. DESCRIPTION DATA Specify the number of times a call can be call forwarded.(1) 14 (2) 01-05 [Number of times (One to five times)] If no data is set, the default setting is 5.CM42 END START
Page 155
CHAPTER 2 ND-45670 (E) Pag e 1 38 Revision 2.0 CALL FORWARDING: MULTIPLE CALL FORWARDING-NO ANSWER PROGRAMMING In addition to the programming for Call Forwarding-No Answer, do the following programming. DESCRIPTION DATA Specify the timing for No Answer after second Call Forwarding.•Y = 0 (1) 46 (2) 01-30: 4 -120 sec. in 4 sec. increments If no data is set, the default setting is 32-36 seconds.CM41 END START
Page 156
ND-45670 (E) CHAPTER 2 Page 139 Revision 2.0 CALL FORWARDING: SPLIT CALL FORWARDING - ALL CALLS (1200 Series Enhancement) PROGRAMMING DESCRIPTION DATA Assign the Class of Service for this feature to the required stations. Note:When providing Call Forwarding-All Calls-Outside, set “1” (Allowed) for YY=00, YY=26 of CM15• CM12 YY=02 [Service Restriction Class (A) (00- 15 )] • CM15 YY=00 (Call Forwarding-All Calls) • CM15 YY=26 (Call Forwarding-All Calls-Outside) (1) XX: Service Restriction Class (A)...
Page 157
CHAPTER 2 ND-45670 (E) Pag e 1 40 Revision 2.0 CALL FORWARDING: SPLIT CALL FORWARDING - ALL CALLS (1200 Series Enhancement) DESCRIPTION DATA Assign whether or not an extention can set Split Call Forwarding-All Calls-Outside by entering only a trunk access code.(1) 386 (2) 0: Restrict 1 : Allow Assign whether or not the system should check the trunk restriction class of the forwarded station during a Split Call Forwarding-All Calls-Outside.(1) 387 (2) 0: Split Call forwarding-All Calls-Out- side...
Page 158
ND-45670 (E) CHAPTER 2 Page 141 Revision 2.0 CALL FORWARDING: SPLIT CALL FORWARDING-ALL CALLS (1200 Series Enhancement) Note:The operating procedure for Split Call Forwarding-All Calls is as follows: CM78 is used to assign the destination forwarded when the destination No. 0-7 is specified. Dial Destination No. X (0-9) Dial Access Code for Split Call Forwarding - All Calls.0: BLOCK No. 0 1: 1 2: 2 3: 3 Destination assigned by 4: 4 CM78. 5: 5 6: 6 7:BLOCK No. 7 8:Destination for Call Forwarding-All Calls...
Page 159
CHAPTER 2 ND-45670 (E) Pag e 1 42 Revision 2.0 CALL FORWARDING: SPLIT CALL FORWARDING-BUSY LINE (1200 Series Enhancement) PROGRAMMING DESCRIPTION DATA Assign the Class of Service for this feature to the required stations. Note:To provide this feature, set “1” (Allowed) for YY=11, YY=28, YY =12, YY=29 of CM15.• CM12 YY = 02 [Service Restriction Class (A) (0015 )] • CM15 YY = 11 (Call Forwarding-Busy Line) • CM15 YY = 28 (Call Forwarding-Busy Line-Outside) • CM15 YY=12 (Call Forwarding-Busy Line/-No...
Page 160
ND-45670 (E) CHAPTER 2 Page 143 Revision 2.0 CALL FORWARDING: SPLIT CALL FORWARDING-BUSY LINE (1200 Series Enhancement) DESCRIPTION DATA To apply this feature to incoming calls, set the trunk route combinations for Tandem Connec- tion.• CM35 YY=05 (1) Trunk Route No. (00-63) Note (2) 1 : Release Signal arriveNote Note: For Resident System Programming, refer to the Command Manual.• CM36 (1) Incoming Trunk Route No. + Outgoing Trunk Route No. (Assigned by CM35 YY=05) (2) 0: Allowed Specify the setting...