Page 171

CHAPTER 2 ND-45670 (E)
Pag e 1 54
Revision 2.0
CALL PICKUP-DIRECT
PROGRAMMING
DESCRIPTION DATA
Assign Service Restriction Class (A) to each 
station.• YY = 02
(1) X-XXXX: Station Number
(2) XX
 XX
*a: Service Restriction Class (A)
(00-15 )
Assign this feature to Service Restriction 
Class (A) assigned by CM12 YY = 02.• YY = 14
(1) XX: Service Rest. Class (A) assigned 
by CM12 YY = 02.
(2) 1 : Allowed
Assign the access code for Call Pickup-
Direct.• Y = 0-3 ( Numbering Plan Group 0-3)
(1) X-XXX: Access...

Page 172

ND-45670 (E) CHAPTER 2
Page 155
Revision 2.0
CALL PICKUP-GROUP
PROGRAMMING
Note 1:There is no limit to the amount of Call Pickup Groups.
Note 2::
The maximum number of stations within a group is 60. Individual stations can be assigned to only one Call
Pickup Group.
DESCRIPTION DATA
Assign each Call Pickup Group, by assigning 
station numbers within a group one by one 
with the following operation:
Example:
  For assigning Stations 300, 301 
and 302 to the same Call Pickup 
Group:
1st Operation (1) 300...

Page 173

CHAPTER 2 ND-45670 (E)
Pag e 1 56
Revision 2.0
CALL PICKUP-DESIGNATED GROUP
PROGRAMMING
Note 1:There is no limit to the amount of Call Pickup Groups.
Note 2:The maximum number of stations within a group is 60. Individual stations can be assigned to only one Call
Pickup Group.
DESCRIPTION DATA
Assign each Call Pickup Group, by assigning 
station numbers within a group one by one 
with the following operation: 
Example:
For assigning Stations 300, 301 
and 302 to the same Call Pickup 
Group:
1st Operation...

Page 174

ND-45670 (E) CHAPTER 2
Page 157
Revision 2.0
CALL REDIRECT
(1800 Series Enhancement)
PROGRAMMING
DESCRIPTION DATA
Provide the Multiline Terminal with a Call 
Redirect key for transferring a call to a 
destination station or VMS.• YY=00
(1) Primary Extension No. +   + Key No. 
(2) F5011: Call Redirect 0
(For transferring to a station as-
signed by CM51 YY=22)
F5012: Call Redirect 1
(For transferring to a VMS as-
signed by CM51 YY=18)
Specify the destination VMS station of Call 
Redirect, to each tenant.•...

Page 175

CHAPTER 2 ND-45670 (E)
Pag e 1 58
Revision 2.0
CALL TRANSFER-ATTENDANT
PROGRAMMING
DESCRIPTION DATA
Assign the Access code for operator calls. • Y = 0-3 (Numbering Plan Group 0-3) 
(1) X-XXX: Access Code (0) 
(2) 800 
Specify the tenants to be handled by each 
ATT Group.• Y =0-3 (ATT Group 0-3 assigned by 
CM60 YY = 00) 
(1) 00-63 (Tenant No.)
(2) 0: To be handled
Specify Call Transfer from a station before 
the called SN610 ATTCON answers.(1) 063 
(2) 0/1  Available/Not Available
CM08 START
END
CM62...

Page 176

ND-45670 (E) CHAPTER 2
Page 159
Revision 2.0
CAMP-ON
PROGRAMMING
Camp-On (Transfer Method)
DESCRIPTION DATA
Provide the system with the Camp-On by 
Station feature. (1) 146 : Automatic Camp-On
(2) 0 : Available
(1) 147 : Manual Camp-On (Result of 
Switch Hook-Flash while hearing 
Busy Tone.)
(2) 0 : Special Dial Tone allowing use of 
Camp-On by Station access code.
Assign the Class of Service for Camp-On to 
the required stations.• CM12 YY = 02 
[Service Rest. Class (A) (00-15 )]
• CM15 YY = 16 (Transfer...

Page 177

CHAPTER 2 ND-45670 (E)
Pag e 1 60
Revision 2.0
CAMP-ON
Camp-On (Call Waiting Method)
Note:For the data assignment of the ANS key to answer a Camp-On call from a Multiline Terminal, refer to the
ANSWER Key. 
DESCRIPTION DATA
Provide the system with the Camp-On by 
Station feature. (1) 146:Automatic Camp-On
(2) 0 : Available
(1) 147 : Manual Camp-On (Result of 
Switch Hook Flash while hearing 
Busy Tone.) 
(2) 0 : Special Dial Tone allowing use of 
Camp-On by access code.
Assign the Class of Service for...

Page 178

ND-45670 (E) CHAPTER 2
Page 161
Revision 2.0
CAMP-ON
When using a Single-Digit Feature-Access Code for Camp-On, add the following system data.
DESCRIPTION DATA
To activate the Single Digit Feature Access 
Code, set the data for 050, 051, 069 and 148 
to “1”.(1) 050: * Button as Switch Hook Flash
(2) 1  Ineffective
(1) 051: # Button as Switch Hook Flash
(2) 1  Ineffective
(1) 069:Single Digit Dialing on BT Con-
nection
(2) 1  Step Call
(1) 148:Same Last Digit Redialing on BT 
Connection 
(2) 1...

Page 179

CHAPTER 2 ND-45670 (E)
Pag e 1 62
Revision 2.0
CCSA ACCESS
PROGRAMMING
In addition to the programming of E&M Tie Line Access, assign CCSA line to the required routes, as shown below.
HARDWARE REQUIRED 
PN-2ODT card ´ n
DESCRIPTION DATA
Assign CCSA line to required routes. • YY = 00
(1) 00-63 (Trunk Route No.) (06)
(2) 03: CCSA line
Specify the ICI key, for the ATTCON, to 
which a CCSA incoming call from the CCSA 
network will terminate.• YY = 15
(1) Trunk Route No. (00-63) 
(2) ICI key 
30: CCSA Incoming...

Page 180

ND-45670 (E) CHAPTER 2
Page 163
Revision 2.0
CENTREX COMPATIBILITY
PROGRAMMING
In addition to the programming of DIRECT OUTWARD DIALING (DOD), do the following programming.
DESCRIPTION DATA
Assign the Centrex Trunk function to the 
required trunk routes. • YY = 86
(1) Trunk Route No. (00-63) 
(2) 0: Centrex Trunk
Provide the capability for sending a 
hookflash signal to the Centrex. • YY = 16
(1) Trunk Route No. (00-63) 
(2) 1  Sending
Assign the access code for sending a 
hookflash signal to the Centrex...