Page 211

CHAPTER 2 ND-45670 (E)
Pag e 1 94
Revision 2.0
DIRECT INWARD DIALING (DID)
DESCRIPTION DATA
Assign the data for DID to the Trunk Routes 
assigned by CM30. • YY = 00 (Kind of Trunk)
(1) Trunk Route No. (00-63)(03)
(2) 00: DID 
• YY = 02 (OG/IC)
(1) Trunk Route No. (00-63)(03) 
(2) 1: Incoming
• YY = 05 (Release Signal Condition) 
(1) Trunk Route No. (00-63)
(2) 0: No Release Signal
• YY = 12 (Number of digits to be re-
ceived)
(1) Trunk Route No. (00-63) 
(2) Number of digits 
0 : 1 digit
1 : 2 digits 
2...

Page 212

ND-45670 (E) CHAPTER 2
Page 195
Revision 2.0
DIRECT INWARD DIALING (DID)
DESCRIPTION DATA
Assign the function of each Digital 
Announcement Trunk, if needed.• YY = 00
(1) 000-127: Digital Announcement 
Trunk Circuit No. 
(2) 0DD0: Announcement Service 
when the called station does 
not answer the DID/Tie Line 
call
0800: Announcement Service 
when the DID/Tie Line call 
terminates to the Busy sta-
tion. 
Automatic Transfer Destinations:
For the DID line, the destination to which an 
incoming call...

Page 213

CHAPTER 2 ND-45670 (E)
Pag e 1 96
Revision 2.0
DIRECT INWARD DIALING (DID)
HARDWARE REQUIRED 
PN-AUCA card ´ n 
DESCRIPTION DATA
When the data for CM35 YY = 18 is set to 
“0” (Received Digits Conversion is to be 
provided), assign the data for interpreting the 
digits received.• Y = 0 (Day Mode) 
• Y = 1 (Night Mode) 
(1) X-XXXX: Station Number received.
(2) X-XXXX: Station Number to be ter-
minated. 
DXX: Change Terminating System to:
D01:
D13: TAS 
D04: DIT 
D14: SN610 ATTCON
D16: DISA
D09: AUTO ATT....

Page 214

ND-45670 (E) CHAPTER 2
Page 197
Revision 2.0
DIRECT INWARD DIALING (CALL WAITING)
DESCRIPTION DATA
Specify the Camp-On tone sent to a busy 
station by Camp-On Call Waiting Method.(1) 367 
(2) 0: Every 4 sec.
Only once
Assign the Class of Service for the Call 
Waiting feature to the required stations.• CM12, YY=02[Service Restriction 
Class (A) (00-15 )]
• CM15, YY=44 (Call Waiting Method 
Answer from called side)
(1) Service Restriction Class (A) (00-15) 
assigned by CM12, YY=02
(2) 1 : Allowed
Assign...

Page 215

CHAPTER 2 ND-45670 (E)
Pag e 1 98
Revision 2.0
DIRECT INWARD DIALING (CALL WAITING)
DESCRIPTION DATA
Assign DID incoming LDN display on 
Multiline Terminal.
Note:When 2nd Data is set to “1”, the Trunk
ID number assigned by CM30, YY=19
is displayed.
• YY=75 (DID incoming LDN display on 
Multiline Terminal)
(1) Trunk Route No. (00-63)
(2) 0 : Available
1 : Not Available - 
Note
END
START
CM35 

Page 216

ND-45670 (E) CHAPTER 2
Page 199
Revision 2.0
DIRECT INWARD SYSTEM ACCESS (DISA)
PROGRAMMING
To provide the DISA without Application Processor (PN-AP01):
DESCRIPTION DATA
Designate the processor for checking the ID 
code on DISA. (1) 217 
(2) 0: MP (PN-CP00) 
Assign the ring rate on a DISA call. (1) 180 
(2) 0/1: 0.2 sec. ON, 0.2 sec. OFF, 0.2 
sec. ON, 0.2 sec. OFF, 0.2 sec. 
ON, 0.2 sec. OFF/As per the data 
of CM35 YY = 33
Assign the data for DISA to the required 
trunks.• YY = 02 (Terminating System...

Page 217

CHAPTER 2 ND-45670 (E)
Pag e 2 00
Revision 2.0
DIRECT INWARD SYSTEM ACCESS (DISA)
Note:Up to 8 DISA ID Codes can be set per system.
DESCRIPTION DATA
When the data for CM35 YY = 18 is set to 0, 
assign the data for converting the received 
digit(s) to DISA. • Y = 0 (Day Mode) 
• Y = 1 (Night Mode) 
(1) X-XXXX: Station No. received
(2) D16: DISA 
Assign the ID code for DISA. The maximum 
number of digits for an ID code is specified 
by CM42-13.•Y = 5
(1) XX : 00-07 (ID code serial 
number) 
(2) X-X...X :...

Page 218

ND-45670 (E) CHAPTER 2
Page 201
Revision 2.0
DIRECT INWARD SYSTEM ACCESS (DISA)
To provide the DISA with an AP (PN-AP01):
DESCRIPTION DATA
Assign the slot number to the PN-AP01 card. 
The SENSE Switch on the PN-AP01 card 
should be set to the slot number assigned by 
this command. (1) Slot No. (04-15)
(2) 07
Designate the processor for checking the 
DISA ID Codes.
Assign the ring rate on a DISA call.(1) 217 
(2) 1: AP (PN-AP01) 
(1) 180 
(2) 0/1: 0.2 sec. ON, 0.2 sec. OFF, 0.2 
sec. ON, 0.2 sec. OFF, 0.2...

Page 219

CHAPTER 2 ND-45670 (E)
Pag e 2 02
Revision 2.0
DIRECT INWARD SYSTEM ACCESS (DISA)
DESCRIPTION DATA
Assign the data for digit conversion on DID 
calls to the Route No. assigned by CM30 YY 
= 00 when providing DISA for DID calls. • YY = 18
(1) Trunk Route No. (00-63)
(2) 0/1: To be provided/Not to be pro-
vided 
When the data for CM35 YY = 18 is set to 0, 
assign the data for converting the received 
digit(s) to DISA. • Y = 0 (Day Mode) 
• Y = 1 (Night Mode) 
(1) X-XXXX: Station No. received 
(2) D16:...

Page 220

ND-45670 (E) CHAPTER 2
Page 203
Revision 2.0
DIRECT INWARD SYSTEM ACCESS (DISA)
To access the Digital Announcement Trunk (PN-2DATA) via DISA, add the following programming.
DESCRIPTION DATA
Assign a Digital Announcement Trunk 
Circuit No. to the required LEN.
Note:The Digital Announcement Trunk
Circuit No. must be assigned to the
first LEN (Level 0) and/or the third
LEN (Level 2) of each LT slot.(1) LEN (0000-0511) 
(2) EB000-EB127: Digital Announcement 
Trunk Circuit No. 
For PIM0/1: EB000-EB031  
For...