Page 231

CHAPTER 2 ND-45670 (E)
Pag e 2 14
Revision 2.0
DUAL HOLD
PROGRAMMING
DESCRIPTION DATA
Assign the Class of Service for this feature to 
the required station. •  CM12 YY = 02 
(1)  X-XXXX: Station Number 
(2) XX XX
*a: Service Restriction Class B (00-
15 ) 
•  CM15 YY = 64 
(1)  XX Service Restriction Class B (00-
15) assigned by CM12 YY = 02. 
(2) 1 : Allowed
CM12 START
CM15
END
*a 

Page 232

ND-45670 (E) CHAPTER 2
Page 215
Revision 2.0
E & M TIE LINE ACCESS
PROGRAMMING
DESCRIPTION DATA
Assign a Trunk Number for the PN-2ODT 
card to the required LENs.
Note:The trunk number must be assigned
to the first LEN (Level 0) and/or the
second LEN (Level 1) of each LT
slot. (1) LEN (0000-0511) 
(2) D000-D255 (Trunk No.) 
Assign a Trunk Route access code to each Tie 
Line Trunk route.• Y = 0-3 (Numbering Plan Group 0-3) 
(1) X-XXX: Access Code (81/82) 
(2) 100-163: Trunk Route 00-63 (01/02) 
Assign a...

Page 233

CHAPTER 2 ND-45670 (E)
Pag e 2 16
Revision 2.0
E & M TIE LINE ACCESS
DESCRIPTION DATA
Assign Trunk Route data to the Trunk Route 
Number assigned by CM30 YY = 00. •   YY = 00 (Kind of Trunk Route) 
(1)  Trunk Route No. (00-63) (01/02) 
(2)  04 (Tie Line) 
•  YY = 01
(1)  Trunk Route No. (00-63) (01/02) 
(2)  < Incoming > < Outgoing > 
2 : DP-10PPS DP 10PPS 
4 : DTMF DTMF
 7 : DTMF/DP DTMF
•  YY = 02 (IC/OG) 
(1)  Trunk Route No. (00-63) (01/02) 
(2) 1 : Incoming Trunk
2 : Outgoing Trunk
 3 : Bothway...

Page 234

ND-45670 (E) CHAPTER 2
Page 217
Revision 2.0
E & M TIE LINE ACCESS
DESCRIPTION DATA
•  YY = 13 (Maximum Number of Send-
ing Digits) 
(1)  Trunk Route No. (00-63) 
(2)  001-031: 1 -31 digits
If no data is set, sender is released when time
out occurs or the called station answers. 
Assign the appropriate data for the 
characteristic of the distant PBX.•  YY = 20 (Sender Start Condition) 
(1)  Trunk Route No. (00-63) (01/02) 
(2) 00: Wink Start
01: Delay Dial 
15: Timing Start (As per YY = 21) 
The above...

Page 235

CHAPTER 2 ND-45670 (E)
Pag e 2 18
Revision 2.0
E & M TIE LINE ACCESS
DESCRIPTION DATA
When YY = 01 is 2, assign the data for the 
DP Sender Characteristics. •  YY = 23 (DP Sender Inter Digital 
Pause) 
(1)  Trunk Route No. (00-63) 
(2) 0 : 300 ms 
1 : 400 ms 
2 : 500 ms 
3 : 600 ms 
4 : 700 ms 
5 : 900 ms 
6 : 1100 ms 
7 : 800 ms
•  YY = 25 (DP Sender Make Ratio) 
(1)  Trunk Route No. (00-63) 
(2)  0/1 : 33% Make Ratio/39% Make 
Ratio
• YY = 45 (DP Sender Release Timing) 
(1)  Trunk Route No. (00-63)...

Page 236

ND-45670 (E) CHAPTER 2
Page 219
Revision 2.0
E & M TIE LINE ACCESS
DESCRIPTION DATA
•  YY = 46 (DTMF Sender Release Tim-
ing) 
(1)  Trunk Route No. (00-63) 
(2) 0 : 2 sec 
1: 4 sec 
2: 6 sec 
3: 8 sec
4 : 12 sec 
5 : 14 sec 
6 : 16 sec
7 : 10 sec
Specify the desired Station Ringing Cadence 
and Multiline Terminal Tone Ringer. •  YY = 33 (Ringing Cadence) 
(1)  Trunk Route No. (00-63) 
(2)  2 : 1 sec ON, 2 sec OFF
3 : 2 sec ON, 4 sec OFF 
To make this data assignment effective
enter the data “1” for...

Page 237

CHAPTER 2 ND-45670 (E)
Pag e 2 20
Revision 2.0
E & M TIE LINE ACCESS
DESCRIPTION DATA
Specify the value of the Tie Line Pad of 
PN-2ODT. •  YY = 19
(1)  Trunk Route No. (00-63) 
(2) 0 
1 
2
3
4 
5 
6 
7
When using the programmable PAD (CM35 
YY = 19, 2nd data = 0-3), assign the PAD 
data. 
(1)  50-65 (See the following Table) 
(2)  00-15 (See the following Table) 
CM35
F
E
CM42
T/R : Transmit/Receive
CONNECTION PATTERNS
(A-B)PAD DATA OF B TRUNK
D ATA = 4  ( T / R ) D ATA = 5  ( T / R ) D ATA = 6  ( T / R...

Page 238

ND-45670 (E) CHAPTER 2
Page 221
Revision 2.0
E & M TIE LINE ACCESS
DESCRIPTION DATA
Specify the restriction of incoming call 
termination to different Tenants.•  Y = 2 
(1) XX
XX
*a: Tenant No. of called station
*b: Tenant No. of Trunk Route
(2) 0/1 : Restricted/Allowed 
Provide DTMF Receivers for Tie Line 
incoming calls, if required.•  Y = 1
(1) XX
X
*a: Card No. (00-15) assigned by 
CM10 (E200-E215) 
*b: Circuit No. (0-3) 
(2)  0 : Only for Tie Line
CM42
F
END
CM63
CM45
T/R : Transmit/Receive
PATTERN...

Page 239

CHAPTER 2 ND-45670 (E)
Pag e 2 22
Revision 2.0
ENHANCED 911
PROGRAMMING
DESCRIPTION DATA
Assign a slot number to 911 Sender trunk.
The slot number is given by the SENSE 
switch on the 911 Sender trunk.
Assign 911 Sender trunk number to each 911 
Sender trunk.(1) Slot No. (04-15)
(2) 19 (PN-ME00 card)
• YY=04
(1) XX: 911 Sender trunk No. (00-15)
(2) XX
 X
Provide the system with Enhanced 911. (3) 474 (Enhanced 911)
(4) 0: Provided
Specify whether the Sender Tone will be sent 
when a call originated, or...

Page 240

ND-45670 (E) CHAPTER 2
Page 223
Revision 2.0
ENHANCED 911
DESCRIPTION DATA
Set the trunk route that no answer signal 
arrives from the distant office for outgoing 
connection.• YY=04 (Answer Signal from distant of-
fice.
(1) Trunk Route No. (00-63
(2) 3: No Answer signal
(Polarity Reversal is ignored)
Specify incoming connection signaling.
Note:PN-24DTA must be set to Wink
Start. PN-20DT and AN-4COT must
be set to Ring Down. Enhanced 911
will not function if PN-20DT is set
to Wink Start.• YY=09 (Incoming...
Start reading NEC Neax2000 Ivs Feature Programming Manual