Page 231
CHAPTER 2 ND-45670 (E) Pag e 2 14 Revision 2.0 DUAL HOLD PROGRAMMING DESCRIPTION DATA Assign the Class of Service for this feature to the required station. • CM12 YY = 02 (1) X-XXXX: Station Number (2) XX XX *a: Service Restriction Class B (00- 15 ) • CM15 YY = 64 (1) XX Service Restriction Class B (00- 15) assigned by CM12 YY = 02. (2) 1 : Allowed CM12 START CM15 END *a
Page 232
ND-45670 (E) CHAPTER 2 Page 215 Revision 2.0 E & M TIE LINE ACCESS PROGRAMMING DESCRIPTION DATA Assign a Trunk Number for the PN-2ODT card to the required LENs. Note:The trunk number must be assigned to the first LEN (Level 0) and/or the second LEN (Level 1) of each LT slot. (1) LEN (0000-0511) (2) D000-D255 (Trunk No.) Assign a Trunk Route access code to each Tie Line Trunk route.• Y = 0-3 (Numbering Plan Group 0-3) (1) X-XXX: Access Code (81/82) (2) 100-163: Trunk Route 00-63 (01/02) Assign a...
Page 233
CHAPTER 2 ND-45670 (E) Pag e 2 16 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA Assign Trunk Route data to the Trunk Route Number assigned by CM30 YY = 00. • YY = 00 (Kind of Trunk Route) (1) Trunk Route No. (00-63) (01/02) (2) 04 (Tie Line) • YY = 01 (1) Trunk Route No. (00-63) (01/02) (2) < Incoming > < Outgoing > 2 : DP-10PPS DP 10PPS 4 : DTMF DTMF 7 : DTMF/DP DTMF • YY = 02 (IC/OG) (1) Trunk Route No. (00-63) (01/02) (2) 1 : Incoming Trunk 2 : Outgoing Trunk 3 : Bothway...
Page 234
ND-45670 (E) CHAPTER 2 Page 217 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA • YY = 13 (Maximum Number of Send- ing Digits) (1) Trunk Route No. (00-63) (2) 001-031: 1 -31 digits If no data is set, sender is released when time out occurs or the called station answers. Assign the appropriate data for the characteristic of the distant PBX.• YY = 20 (Sender Start Condition) (1) Trunk Route No. (00-63) (01/02) (2) 00: Wink Start 01: Delay Dial 15: Timing Start (As per YY = 21) The above...
Page 235
CHAPTER 2 ND-45670 (E) Pag e 2 18 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA When YY = 01 is 2, assign the data for the DP Sender Characteristics. • YY = 23 (DP Sender Inter Digital Pause) (1) Trunk Route No. (00-63) (2) 0 : 300 ms 1 : 400 ms 2 : 500 ms 3 : 600 ms 4 : 700 ms 5 : 900 ms 6 : 1100 ms 7 : 800 ms • YY = 25 (DP Sender Make Ratio) (1) Trunk Route No. (00-63) (2) 0/1 : 33% Make Ratio/39% Make Ratio • YY = 45 (DP Sender Release Timing) (1) Trunk Route No. (00-63)...
Page 236
ND-45670 (E) CHAPTER 2 Page 219 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA • YY = 46 (DTMF Sender Release Tim- ing) (1) Trunk Route No. (00-63) (2) 0 : 2 sec 1: 4 sec 2: 6 sec 3: 8 sec 4 : 12 sec 5 : 14 sec 6 : 16 sec 7 : 10 sec Specify the desired Station Ringing Cadence and Multiline Terminal Tone Ringer. • YY = 33 (Ringing Cadence) (1) Trunk Route No. (00-63) (2) 2 : 1 sec ON, 2 sec OFF 3 : 2 sec ON, 4 sec OFF To make this data assignment effective enter the data “1” for...
Page 237
CHAPTER 2 ND-45670 (E) Pag e 2 20 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA Specify the value of the Tie Line Pad of PN-2ODT. • YY = 19 (1) Trunk Route No. (00-63) (2) 0 1 2 3 4 5 6 7 When using the programmable PAD (CM35 YY = 19, 2nd data = 0-3), assign the PAD data. (1) 50-65 (See the following Table) (2) 00-15 (See the following Table) CM35 F E CM42 T/R : Transmit/Receive CONNECTION PATTERNS (A-B)PAD DATA OF B TRUNK D ATA = 4 ( T / R ) D ATA = 5 ( T / R ) D ATA = 6 ( T / R...
Page 238
ND-45670 (E) CHAPTER 2 Page 221 Revision 2.0 E & M TIE LINE ACCESS DESCRIPTION DATA Specify the restriction of incoming call termination to different Tenants.• Y = 2 (1) XX XX *a: Tenant No. of called station *b: Tenant No. of Trunk Route (2) 0/1 : Restricted/Allowed Provide DTMF Receivers for Tie Line incoming calls, if required.• Y = 1 (1) XX X *a: Card No. (00-15) assigned by CM10 (E200-E215) *b: Circuit No. (0-3) (2) 0 : Only for Tie Line CM42 F END CM63 CM45 T/R : Transmit/Receive PATTERN...
Page 239
CHAPTER 2 ND-45670 (E) Pag e 2 22 Revision 2.0 ENHANCED 911 PROGRAMMING DESCRIPTION DATA Assign a slot number to 911 Sender trunk. The slot number is given by the SENSE switch on the 911 Sender trunk. Assign 911 Sender trunk number to each 911 Sender trunk.(1) Slot No. (04-15) (2) 19 (PN-ME00 card) • YY=04 (1) XX: 911 Sender trunk No. (00-15) (2) XX X Provide the system with Enhanced 911. (3) 474 (Enhanced 911) (4) 0: Provided Specify whether the Sender Tone will be sent when a call originated, or...
Page 240
ND-45670 (E) CHAPTER 2 Page 223 Revision 2.0 ENHANCED 911 DESCRIPTION DATA Set the trunk route that no answer signal arrives from the distant office for outgoing connection.• YY=04 (Answer Signal from distant of- fice. (1) Trunk Route No. (00-63 (2) 3: No Answer signal (Polarity Reversal is ignored) Specify incoming connection signaling. Note:PN-24DTA must be set to Wink Start. PN-20DT and AN-4COT must be set to Ring Down. Enhanced 911 will not function if PN-20DT is set to Wink Start.• YY=09 (Incoming...