Page 131

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 117
Emergency Call Monitor - Attendant E-21
E-21Emergency Call Monitor - Attendant
General Description
EMERGENCY CALL MONITOR - ATTENDANT alerts the hospitality console operator that a Guest has placed
a call to an emergency service such as 911. The name and room number of the Guest display on the console.
Operating Procedure
1. Guest dials 911. The console emergency call trunk LED (trunk group busy lamp) illuminates.
2. The console...

Page 132

NEAX2400 IPX Hotel Feature Programming ManualPage 118NDA-24304, Issue 1
E-21 Emergency Call Monitor - Attendant
STEP CMND BIT EXPLANATION
2SYS1
ASYD
INDEX
15b
0
Number of Trunk Group (TG) Busy Lamps on Console
0=OutofService
1-F = Number of Trunk Groups (1 - 10) b1
b2
b3
b4
Not used b5
b6
b7
3SYS1
ASYD
INDEX
68b
0Operating method for busy station service (Call back, Executive Right-of-Way, etc.)
0/1 = SHF + Access Code/Last Digit + Access Code
b
1
Operating method for Individual Trunk Access (ATT)...

Page 133

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 119
Emergency Call Monitor - Attendant E-21
4SYS2
ASYD
INDEX
0b
0Restriction Data of Station Busy Services can be designated as indicated below:
R: Restricted A: Allowed b
1
b2Not used
b
3Attendant Override service
0/1 = Out/In Service
b
4Busy Verification (Console) service
0/1 = Out/In Service
b
5
Not used b6
b7
5
ASYD
SYS 1
INDEX
172b
1Message registration (SMDR) information sent to/from PMS.
0/1 = No/YesNote 1
6AHSY
INDEX
109b
0Not...

Page 134

NEAX2400 IPX Hotel Feature Programming ManualPage 120NDA-24304, Issue 1
E-21 Emergency Call Monitor - Attendant
Note 1:These steps are not required if the call to 911 service does not print to the hotel printer.
Note 2:The number entered will automatically print on the hotel printer when the call is completed. (Trunk is
released and SMDR is output.) This works in conjunction with AHSY Index 183, bit 6. SMDR must be in
service. 8
AHSY
360b
0Special Number Message Registration Entry
Block 1
First Digit = 1...

Page 135

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 121
Guest/Administrative Service G-1
G-1Guest/Administrative Service
General Description
This feature enables stations to be classified as Guest stations and administration stations, and to use the respective
numbering plan. This allows a Guest station to call an Administration Station by using a feature access code.
Operating Procedure
No manual operation is required.
Service Conditions
1. Calls between two Administration stations can...

Page 136

NEAX2400 IPX Hotel Feature Programming ManualPage 122NDA-24304, Issue 1
G-1 Guest/Administrative Service
3AGSP
or
AASPAssign the Guest/Administrative Service access code.
(SRV = SSCA, SIDA = 56, PNO, A/G = 0/1)
Note 1:When a Guest station calls an administration station, assign data “0” at A/G.
Note 2:SID: 36, STATE: 32 can be used to allow Guest stations to call administration
stations when a split numbering plan is used. If this is set, it is not necessary to
program AOSP.
4 AOSP Skip the access code...

Page 137

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 123
Group Service Through PMS G-4
G-4Group Service Through PMS
General Description
Group service information is entered via the PMS and forwarded to the NEAX2400 IPX for storage. This enables
the Console, or predetermined Special Administration Stations, to activate various ANNOUNCEMENT
SERVICES [A-15] on a group basis. Ten different types of announcements can be provided for group service.
System limitations are as follows:
64 Groups...

Page 138

NEAX2400 IPX Hotel Feature Programming ManualPage 124NDA-24304, Issue 1
G-4 Group Service Through PMS
Operating Procedure (cont’d)
3. Press theENTERkey. The associated lamp illuminates.
4. Dial the Group code. The console displays the information.
5. Press theENTERkey.
6. Press theEXITkey. The lamp and display are extinguished.
Service Conditions
1. The PMS must be able to supply the NEAX2400 IPX with group service information. This information is
entered from the PMS terminal and forwarded to the...

Page 139

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 125
Group Service Through PMS G-4
Assignment Procedure
STEP CMND BIT EXPLANATION
1SYS1
ASYD
INDEX
160b
0Hotel Feature required (Fixed Data)
b
1Hotel Service kind (Fixed Data)
b
2Length of Room Status Memory
0/1 = 8 byte/24 byte
b
3Pattern of Key Arrangement on Console
(Refer toFigure 4) (Usually, 00)
b
4
b5Guest Name Service
0/1 = Out/In Service
b
6Numbering Plan Data Table of Guest Station and Administration Station
0/1 =...

Page 140

NEAX2400 IPX Hotel Feature Programming ManualPage 126NDA-24304, Issue 1
G-4 Group Service Through PMS
Note:Group assignment and Group Code assignment are executed at PMS terminal.
STEP CMND EXPLANATION
4 AANPAssigns minimum necessary number of digits for the first number of the Group Service Access
Code.
5 AASPAssigns the Group Service Access Code.
 To Set: SRV = 2(SSC), SID =50
 To Cancel: SRV = 2(SSC), SID = 51
6 ASFC SFI 42: Allow for Stations in Group
7ARTDAssign the route data of the trunk that...
Start reading NEC Neax 2400 Ipx Hotel Feature Programming Manual