Page 101
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 87 Do Not Disturb D-11 6AHSY INDEX 139b 0Not used b 1 b2MW Lamp Indication of “Do Not Disturb” 0/1 = Lights Steadily/Flashes b 3MW Lamp Indication of “Do Not Disturb” 0/1 = Not Required/Required b 4MW Lamp Indication of “Message Waiting” 0/1 = Lights Steadily/Flashes b 5MW Lamp Indication of “Message Waiting” 0/1 = Not Required/Required b 62-Line Guest Name Display on a Dterm 0/1 = Out/In Service b 7Not Used 7AHSY INDEX 266b 0Not Used...
Page 102
NEAX2400 IPX Hotel Feature Programming ManualPage 88NDA-24304, Issue 1 D-11 Do Not Disturb 11 ARSCWhen “1” has been assigned by SYS1, INDEX 170, Bit 3, assign restriction data to RSC 14 and 15. Note: Steps after ARTD are necessary only when the destination of the tone of Do Not Disturb call is designated as Announcement Machine. 12 ARTDAssign the route data of the trunk which interfaces with the announcement unit (OSGS = 2, TCL = 4 should be set). 13 ATRK Assign the trunk interfacing with the...
Page 103
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 89 Do Not Disturb - DtermD-11D D-11DDo Not Disturb - Dterm General Description This feature allows a Guest room Dtermto temporarily block incoming calls. Outgoing calls may still be placed from stations in DO NOT DISTURB (DD) mode. Operating Procedure To set DO NOT DISTURB from Guest Room Dterms 1. Lift handset or press theSPEAKERkey. Receive dial tone. 2. Dial the DD set code. Receive service set tone. The LCD displays: 3. Hang up. If...
Page 104
NEAX2400 IPX Hotel Feature Programming ManualPage 90NDA-24304, Issue 1 D-11D Do Not Disturb - Dterm Service Conditions (cont’d) 8. Station in DD mode can receive calls from specific trunk routes or stations through system data assignment. 9. Guest “Boss” and “Secretary” rooms override DD mode for calls between assigned stations. 10. DO NOT DISTURB set by Special Administration Station can be cancelled by Guest station, and vice versa. 11. This feature and DO NOT DISTURB - D termin BUSINESS FEATURE are...
Page 105
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 91 Do Not Disturb - DtermD-11D 3SYS1 ASYD INDEX 162b 0Destination of connection when a connection between Guest stations is restricted. b 1 b2Destination of connection when Room Cutoff is assigned. b 3 b4Assignment of destination for Do Not Disturb. b 5 b6Tone to be given when a wake up call is answered. b 7 4SYS1 ASYD INDEX 170b 0Room status data (b2,b1,b0)tobesetatthetimeofCheckout Note: Do not assign other data. b1 b2 b3 Assignment...
Page 106
NEAX2400 IPX Hotel Feature Programming ManualPage 92NDA-24304, Issue 1 D-11D Do Not Disturb - Dterm 5SYS1 ASYD INDEX 172b 0Message Waiting Data transfer to/from PMS when executing the service. 0/1 = Not to be executed/To be executed b 1Message Registration b 2Do Not Disturb, Room Cutoff 0/1: Out/In Service b 3Room Status b 4Automatic Wake up, Group Announcement b 5Room Change, Room Swap b 6Room Data Change b 7Not used 6AHSY INDEX 77b 0LCD Indication of Wake-Up time on the Dterm 0/1 = -/Remains lit b 1LCD...
Page 107
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 93 Do Not Disturb - DtermD-11D 8AHSY INDEX 376b 0Not usedText sent to PMS printout 0/1 = Not Required/Required If “1” is assigned to the corresponding bit, the text is output to the Hotel printer. Note: When a failure has occurredtoadatalink between the NEAX2400 IPX and the PMS, the pertaining error information is printed out. b1Maid Status-Guest (Feature Code = 11) b 2Maid Status-Admin. (Feature Code = 12) b 3Message Waiting Lamp...
Page 108
NEAX2400 IPX Hotel Feature Programming ManualPage 94NDA-24304, Issue 1 D-15 Day/Night Class of Service D-15Day/Night Class of Service General Description This feature permits all stations within a tenant to alternate between two different CLASS OF SERVICE - INDIVIDUAL [C-15] options, one for Day mode and another for Night mode. System data can be programmed so that once the ATTENDANT CONSOLE [A-3] has entered the NIGHT CONNECTION [N-1, 2] mode, a stations CLASS OF SERVICE - INDIVIDUAL [C-15] will be...
Page 109
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 95 Day/Night Class of Service D-15 Assignment Procedure STEP CMND BIT EXPLANATION 1SYS1 ASYD INDEX 75b 0Route Restriction Class Data (“ARSC” command) 0/1 = Common/Separate Table Development: Common or Separate Day/ Night Data Tables. Note: When data tables are designated as “Common”, the Day mode designation must be used in the respective commands. b1 Service Feature Restriction Class Data (“ASFC” command) 0/1 = Common/Separate b...
Page 110
NEAX2400 IPX Hotel Feature Programming ManualPage 96NDA-24304, Issue 1 D-15 Day/Night Class of Service 6 ATNR Assign Day/Night data. 7 AEFR Assign Day/Night data. 8 ASPF Assign Day/Night data. 9 ASCR Assign Day/Night data. 10 ATCR Assign Day/Night data. ATCR will override ASCR on restriction. 11 ADNRAssign the Time for Day mode and Night mode, if automatic change of Route Restriction Class (RSC) is necessary. STEP CMND EXPLANATION