Home > NEC > Communications System > NEC Neax 2400 Imx Hotel Feature Programming Manual

NEC Neax 2400 Imx Hotel Feature Programming Manual

Here you can view all the pages of manual NEC Neax 2400 Imx Hotel Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 211

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 197
Off-hook Alarm O-6
Note:
This data is required for sending Howler Tone from Hotel Attendant. Refer to SERVICE CONDITIONS.

When the Off-Hook Alarm destination is a specific station:
3SYS1
ASYD
INDEX
168b
0Group Announcement Service through PMS
0/1 = Out/In Service
b
1Audit Reports (for Hotel system)
0/1 = Out/In Service
b
2Not used
b
3
b4Off-Hook Alarm (service)
0/1 = Out/In Service
b
5Destination for Off-Hook Alarm...

Page 212

NEAX2400 IMX Hotel Feature Programming Manual
Page 198ND-70284 (E), Issue 2
O-6 Off-hook Alarm
4ASIDAssign the connection destination to the above GN.
F: Off-Hook Alarm
GN: Group Number assigned in ASGD
S/A: Special Station (Assign S.)
SSTN: Terminated Special Station Number
5ATNRPermit the connection between the special station number tenant and the tenant of the terminating 
Off-Hook Alarm station. STEP CMND EXPLANATION 

Page 213

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 199
Overtime Call O-9
O-9 Overtime Call
General Description
The OVERTIME CALL feature permits the system to measure the length of all outgoing calls, and to print a
message on the hotel printer or alert the Console that the call has exceeded a predetermined time.
Operating Procedure
If the hotel printer is to receive this information, no manual operation is required.
To operate from the Console:
Service Conditions
1. If the...

Page 214

NEAX2400 IMX Hotel Feature Programming Manual
Page 200ND-70284 (E), Issue 2
O-9 Overtime Call
Assignment Procedure
CMND BIT EXPLANATION
SYS1
ASYD
INDEX 
163b
0Over Time Call timer.
b
1b0b1b0
00= 30 min. 10=90 min.
01= 60 min. 11=120 min. b1
b2Over Time Call
0/1 = Out/In Service
b
3Over Time Call indication
0/1 = On Console/Hotel Printer
b
4Step Call from Guest Station is allowed
0/1 = Out Service/In
b
5To n e  t y p e  f o r  M a i d  D i a l i n g
b
6b5b6b500=SST 10= –
0 1 =  Announcement 1 1 = Music on...

Page 215

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 201
Printer Control – Hotel Attendant Console P-8
P-8  Printer Control – Hotel Attendant Console
General Description
A printer should be connected to the NEAX2400 IMX to provide AUDIT REPORTS [A-26], CHECK-IN/
CHECKOUT [C-23], OVERTIME CALL [O-9], and AUTOMATIC WAKE-UP [A-10] set times, and results of
Wake-Up calls. In the event that PMS is provided and then temporarily fails, PMS messages will be sent to this
printer.
Printer...

Page 216

NEAX2400 IMX Hotel Feature Programming Manual
Page 202ND-70284 (E), Issue 2
P-8 Printer Control – Hotel Attendant Console
Assignment Procedure
STEP CMND BIT EXPLANATION
1SYS1
ASYD
INDEX 11b
0I/O Port designation to Hotel Printer (Model 60/90/120 PMS)
b
1
b2
b3
Not used b4
b5
b6Transmission Protocol between PBX and Hotel Printer
b
7
2SYS1
ASYD
INDEX 
165b
0Port Number accommodating the printer for hotel (Model 60 PMS )(Note 1)
b
2b1b0b2b1b0
0 0 0 = Port 0 0 1 1 = Port 3
0 0 1 = Port 1 1 0 0 = Port 4
0 1 0...

Page 217

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 203
Printer Control – Hotel Attendant Console P-8
4AHSY
INDEX
183b
0
Setting of Console that sets Alert Service
0 Hex: Service can be set from any of the Consoles
1–F Hex: Service can be set only from the Console of the designated Console Number b1
b2
b3
b4
Classifying the call termination indicating keys based on the Language category of the 
guest at the time an incoming call from the guest station terminated to the Console.
0/1 =...

Page 218

NEAX2400 IMX Hotel Feature Programming Manual
Page 204ND-70284 (E), Issue 2
P-8 Printer Control – Hotel Attendant Console
6AHSY
INDEX 
362b
0
Digits Code 0
Outgoing Call Access Code No. 2 
(Note 2)Note:
When the dial access code
contains “0”, enter “A”
for “0”.
Example:
When the dial access 
code is “9-202”. b1
b2
b3
b4
Digits Code 1 b5
b6
b7
AHSY
INDEX 
363b
0
Digits Code 2 b1
b2
b3
b4
Digits Code 3 b5
b6
b7
7AHSY
INDEX 
364b
0
Digits Code 0
Outgoing Call Access Code No. 3 
(Note 2)Note:
When the dial...

Page 219

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 205
Printer Control – Hotel Attendant Console P-8
8AHSY
INDEX 
366b
0
Digits Code 0
Outgoing Call Access Code No. 4 
(Note 2)Note:
When the dial access code
contains “0”, enter “A”
for “0”.
Example:
When the dial access 
code is “9-202”
. b1
b2
b3
b4
Digits Code 1 b5
b6
b7
AHSY
INDEX 
367b
0
Digits Code 2 b1
b2
b3
b4
Digits Code 3 b5
b6
b7
9AHSY
INDEX 
376b
0Not used
Text sent to PMS printout
0/1 = Not Required/Required
If “1” is...

Page 220

NEAX2400 IMX Hotel Feature Programming Manual
Page 206ND-70284 (E), Issue 2
P-8 Printer Control – Hotel Attendant Console
Note 1:
The same I/O Port number should be assigned for the Hotel Printer.
Note 2:
This data is not necessary when INDEX 183, Bit 6 is assigned “0”.
Note 3:
When a failure has occurred to a data link between the NEAX2400 IMX and the PMS, the pertaining error information
is printed out.
Note 4:
This data can be assigned when SYS1, ASYD, INDEX 165, Bit 6 is “1”. 11AHSY
INDEX
400“Hour”...
Start reading NEC Neax 2400 Imx Hotel Feature Programming Manual

Related Manuals for NEC Neax 2400 Imx Hotel Feature Programming Manual

All NEC manuals