Page 231
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 217 Paging Console P-34 Assignment Procedure STEP CMND BIT EXPLANATION 1SYS1 ASYD INDEX 73b 0Type of Paging Service b 1b0b1b0 00=No Answer 10= Delay 0 1 = None Delay 1 1 = Delay with Paging Transfer b 1 b2 Radio Page Number (SIM/IMG = 2 Digits only) 0/1 = 2 digits/3 digits b 3Paging Cancel Code 0/1 = Individual Paging Route Codes/Common to all Paging Routes b 4Radio Paging – station number is automatically sent. 0/1 = Out/In...
Page 232
NEAX2400 IMX Hotel Feature Programming Manual Page 218ND-70284 (E), Issue 2 P-34 Paging Console 4AHSY INDEX 104b 0Miscellaneous Timer Class (MTC) is to be assigned a value from 0 Hex to F Hex (0–15).Paging Console Automatic Recall Timer: Timer Value Setting is MTC × ×× × TC sec. Note: When this data is 00 Hex, ROM data is automatically set to 3 min. b 1 b2 b3 b4Timer Class Length (TCL) is to be assigned one of the following values: b 6b5b4b6b5b4 000= – 100= 64 sec. 001= 8 sec. 101= – 010= 16...
Page 233
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 219 Room Cutoff R-9 R-9 Room Cutoff General Description This feature allows the Console, PMS terminal, or Front Desk Terminal to temporarily restrict outgoing CO calls from guest room telephones while the guests are away. Operating Procedure To set ROOM CUTOFF from Console or Front Desk Terminal: Note: If the “RC” steady display is available by system data, the following will display on a Guest station Dterm: To cancel ROOM...
Page 234
NEAX2400 IMX Hotel Feature Programming Manual Page 220ND-70284 (E), Issue 2 R-9 Room Cutoff Service Conditions 1. Stations in ROOM CUTOFF mode that attempt to access C.O. lines will be routed to a reorder tone connection, the Console, or an announcement on a system-wide basis. 2. Stations in ROOM CUTOFF mode may be able to place outgoing C.O. calls via the Attendant, depending on the restriction data assigned via the MAT. 3. ROOM CUTOFF is available for guest room stations only. 4. Through system data...
Page 235
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 221 Room Cutoff R-9 Note: If unconditional restriction is set as per the OG restriction and IC restriction information, or if OG restriction and IC restriction are set to Guest stations, the present Route Restriction Class is temporarily replaced with RSC 13–15, and whether restriction is executed or not is selected from the Restriction Table. 2SYS1 ASYD INDEX 170b 0Room status data (b2, b1, b0) to be set at the time of Checkout b...
Page 236
NEAX2400 IMX Hotel Feature Programming Manual Page 222ND-70284 (E), Issue 2 R-10 Room Status R-10 Room Status General Description This feature provides a ROOM STATUS display on the Console or Front Desk Terminal. The ROOM STATUS display indicates the following: AUTOMATIC WAKE-UP [A-10] DO NOT DISTURB [D-11] GUEST NAME DISPLAY through PMS [G-5] MESSAGE WAITING [M-6] ROOM CUTOFF [R-9] Room Occupied Room Reserved Station number VIP (PMS option) Operating Procedure To display ROOM STATUS on the Console...
Page 237
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 223 Room Status R-10 Assignment Procedure STEP CMND BIT EXPLANATION 1SYS1 ASYD INDEX 11b 0I/O Port designation to Hotel Printer (Model 60/90/120 PMS) b 1 b2 b3 Not Used b4 b5 b6Transmission Protocol between PBX and Hotel Printer b 7 2SYS1 ASYD INDEX 168b 0Group Announcement Service (for Hotel system) 0/1 = Out/In Service b 1Audit Reports 0/1 = Out/In Service b 2Not used b 3 b4Off-Hook Alarm (service) 0/1 = Out/In Service b...
Page 238
NEAX2400 IMX Hotel Feature Programming Manual Page 224ND-70284 (E), Issue 2 R-10 Room Status 4AHSY INDEX 179b 0 Not used b1 b2 b3 b4Designation of Guest Station Access Code b 7b6b5b4ACC · CODE b7b6b5b4ACC · CODE 0000 Out of Service 0 1 1 1 7 0001 1 1 0 0 0 8 0010 2 1 0 0 1 9 0011 3 1 0 1 0 0 0100 4 1 0 1 1 * 0101 5 1 1 0 0 # 0110 6 b5 b6 b7 STEP CMND BIT EXPLANATION
Page 239
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 225 Room Numbering R-17 R-17 Room Numbering General Description This feature enables flexible assignment of station numbers based on the guest ROOM NUMBERING plan. Operating Procedure Guest room calls are completed in the same manner as calls to ordinary stations. Service Conditions 1. The same station number cannot be assigned to more than one station in the system. 2. Guest numbers must be contained within Tenant 1. 3. One-, two-,...
Page 240
NEAX2400 IMX Hotel Feature Programming Manual Page 226ND-70284 (E), Issue 2 R-17 Room Numbering Assignment Procedure Note: If the data is assigned as “1”, only use commands AANP & AAST to assign Administration and Guest Station Numbering Plan. If data “0” is assigned, use AANP & AAST for Administration Numbering Plan, and AGNP & AGST for Guest Numbering Plan. STEP CMND BIT EXPLANATION 1SYS1 ASYD INDEX 160b 0Hotel Feature required (Fixed Data) b 1Hotel Service kind (Fixed Data) b 2Length of Room Status...