Home > NEC > Communications System > NEC Neax 2400 Imx Hotel Feature Programming Manual

NEC Neax 2400 Imx Hotel Feature Programming Manual

Here you can view all the pages of manual NEC Neax 2400 Imx Hotel Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 221

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 207
PMS Interface – BISYNC P-27
P-27  PMS Interface – BISYNC
General Description
The PMS INTERFACE service feature provides an interface to the Property Management System (PMS) computer
using the standard IBM® BISYNC (Binary Synchronous Communication) protocol. This interface allows a PMS
computer to accommodate both front and back office hospitality management features.
Note:
IBM® is a registered trademark of International Business...

Page 222

NEAX2400 IMX Hotel Feature Programming Manual
Page 208ND-70284 (E), Issue 2
P-27 PMS Interface – BISYNC
Assignment Procedure
STEP CMND BIT EXPLANATION
1SYS1
ASYD
INDEX 10
Model 90, 
120b
0I/O Port designation to PMS Computer(Note 2)
b
2b1b0 b2b1b0
0 0 0  = Port 0 0 1 1 = Port 3
0 0 1 =  Port 1 1 0 0 = Port 4
0 1 0  = Port 2 1 0 1 = Port 5
110= Port 6
111= Port 7 b1
b2
b3Not used
b
4
b5
b6Transmission Protocol between PBX and PMS Computer
b
7b6b7b6
0 0 =  Out of Service 1 0 = BSC
0 1 = Level 2A 1 1 = Free...

Page 223

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 209
PMS Interface – BISYNC P-27
Note 1:
INDEX 190 and 191 should be assigned when the following service features are required:
Directory Assistance Interface  [D-88]
Guest Information Display – Console [G-8]
Guest Information Display – PMS Terminal  [G-9]
For details, refer to the Assignment Procedures for the above service features. The different port number should be
entered into INDEX 175, INDEX 190, and INDEX 10.
Note 2:
The...

Page 224

NEAX2400 IMX Hotel Feature Programming Manual
Page 210ND-70284 (E), Issue 2
P-29 PMS Interface
P-29 PMS Interface
General Description
The PMS INTERFACE provides a data link between the NEAX2400 IMX and the customers Property Management
System (PMS) computer. This communications link enables the PMS-related hospitality management functions.
Major functions and their communication interactions are indicated below:
AUTOMATIC WAKE-UP  [A-10] IMX PMS
AUTOMATIC MESSAGE WAITING LAMP OFF  [A-48] IMX PMS...

Page 225

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 211
PMS Interface P-29
Service Conditions (cont’d)
3. Message format:
Note:
The Block Check Code is for the Longitudinal Redundancy Check.
On detecting STX, the computation starts (STX is excluded).
On detecting ETX, the computation ends (ETX is included).
4. Data format and contents of TEXT are in conformity with Bell System Voice Communications Technical
Reference Publication No. 42707, PMS Data Link Interface Specifications....

Page 226

NEAX2400 IMX Hotel Feature Programming Manual
Page 212ND-70284 (E), Issue 2
P-29 PMS Interface
3SYS1
ASYD
INDEX
172b
0Message Waiting Information
Data transfer to/from PMS 
when executing the service.
0/1 = Not to be executed/To be 
executed b
1Message Registration
b
2Do Not Disturb, Room Cutoff
b
3Room Status
b
4Automatic Wake-Up, Group Announcement
b
5Room Change, Room Swap
b
6Room Data Change
b
7Not used
4SYS1
ASYD
INDEXES 
190 & 191
(Note)b
0I/O = Designation of PMS Port (for Line No. 2/3)
b...

Page 227

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 213
PMS Interface P-29
Note:
INDEX 190 and 191 should be assigned when the following Service features are required:
Directory Assistance Interface [D-88]
Guest Information Display – Console [G -8]
Guest Information Display – PMS Terminal [G-9]
Maid Status Answer Back [M-68]
For details, refer to the ASSIGNMENT PROCEDURE for the above service features. The different port numbers
should be entered into INDEX 10, INDEX 190, and INDEX...

Page 228

NEAX2400 IMX Hotel Feature Programming Manual
Page 214ND-70284 (E), Issue 2
P-29 PMS Interface
165 Checkout Message Off Report
The specific guest room, a state is provided when a 
Checkout Report has been received pertaining to a 
guest room. 6 Checkout Message On Report
C Checkout C. O line OG Call Report
D Checkout Message Waiting Report
172Room Data Image – Room Data 
ReportWhen the room data has been requested from the 
PMS, the following room data reported/
exchanged:
 Station Number
 Out/Stay...

Page 229

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 215
PMS Interface P-29
511 Maid Status – Guest Room 1
These texts are used with Maid Status Answer-
Back System. When Maid Status Answer Back 
Access Code has been dialed via guest/admi. 
station the following data is sent to PMS:
Stations Number
Maid Identification Number
LENs (Line Equipment Number)
The kind of text information to be used depends on 
the software at the PMS side. 2 Maid Status – Guest Room 2
3 Maid Status – Guest...

Page 230

NEAX2400 IMX Hotel Feature Programming Manual
Page 216ND-70284 (E), Issue 2
P-34 Paging Console
P-34 Paging Console
General Description
The PAGING CONSOLE feature allows a Console operator to transfer an incoming call to a PAGING CONSOLE
when the guest is not in his or her room. The PAGING CONSOLE operator pages the guest through the hotel public
address system, requesting him or her to dial a special number from a nearby telephone. When the guest calls, the
PAGING CONSOLE operator connects the guest to...
Start reading NEC Neax 2400 Imx Hotel Feature Programming Manual

Related Manuals for NEC Neax 2400 Imx Hotel Feature Programming Manual

All NEC manuals