Page 81

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 73
DESCRIPTION DATA
Assign the access code of paging groups
for Group Call-Automatic Conference (6/
10-Par ty).
NOTE:Even if an extension does not
belong to the conference group,
the extension can page the
conference group, and can re-
participate in the conference if
thereisanidlecircuitonthe
Conference Trunk.
(1)
(2)Y=0-3 (Tenant Group No.)
X-XXXX: Access Code
A200 : Simultaneous...

Page 82

NEAX2000 IVS2WCS System Manual (PCS)Page 74ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
Group Call-2 Way Calling
Refer to the WCS Features and Specifications.
DESCRIPTION DATA
Assign the stations which belongs to each
paging group, and their number within the
group. A maximum of nine stations can be
paged simultaneously except the confer-
ence leader.
NOTE 1:Single line telephones, D
terms
and PSs can be assigned as the
station within the group.
A vir tual-line cannot...

Page 83

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 75
Multi-Line Operation-PS
Refer to the WCS Features and Specifications.
DESCRIPTION DATA
Assign a PS station number to the vi rtual
PS number.
(1)
(2)000-255: Virtual PS LEN
X-XXXXXXXX: Primary PS station No.
X-XXXXXXXX: Sub-line PS station No.
Assignthesub-linePSnumbertoeach
primary PS station, both are assigned by
CM1C.
(1)
(2)YY=01
X-XXXXXXXX: Primary PS station No.
X-XXXXXXXX:...

Page 84

NEAX2000 IVS2WCS System Manual (PCS)Page 76ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
To assign the PS station to the line key on the Dterm, assign the following data.
DESCRIPTION DATA
Assign a vir tual PS station number to the
key number of the D
term.
A vir tual PS number of PS sub-line can be
assigned to the key on the D
term.
(1)
(2)YY=00
Primary Extension No. + + Key No.
X-XXXXXXXX: Virtual PS Station No.
END
A
CM90
, 

Page 85

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 77
Number Sharing
Refer to the WCS Features and Specifications.
DESCRIPTION DATA
Specify the combination of the main station
and the sub station, also the contrary
combination, as follows.
1st data : Main station (D
ter mMy Line)
2nd data: Sub station (PS)
1st data : Sub station (PS)
2nd data: Main station (D
ter mMy Line)
NOTE:As the main station number, D
term
My Line number must be...

Page 86

NEAX2000 IVS2WCS System Manual (PCS)Page 78ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
DESCRIPTION DATA
Provide the capability of setting/cancelling
theNumberSharingfromthesubstation.
(1)
(2)YYY=128
00-15: Service Restriction Class A of
main station
1:Notprovide
(1)
(2)00-15: Service Restriction Class A of
sub station
0:Toprovide
Specify whether the sub station is
controlled as same as the main station, by
a Message Waiting lamp control signal
sent from the MCI....

Page 87

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 79
Voice Mail Indication
Refer to the WCS Features and Specifications.
DESCRIPTION DATA
Provide PS stations with Message Waiting
service.
The first data should be the virtual PS
number.
(1)
(2)YY=03
X-XXXXXXXX: Virtual PS No.
0:Provided
(For the station with MW lamp)START
CM13
END 

Page 88

NEAX2000 IVS2WCS System Manual (PCS)Page 80ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Multi-Site Roaming Programming
MULTI-SITE ROAMING PROGRAMMING
According to the following procedure, assign the system data for Roaming service.
PREPARATION
CONFIRMING NETWORK NUMBERING PLAN
(OPEN NUMBERING SYSTEM/
CLOSED NUMBERING SYSTEM)
START
NETWORK NUMBERING PLAN PROGRAMMING
(OPEN NUMBERING SYSTEM/
CLOSED NUMBERING SYSTEM)
Q931a DIGITAL TRUNK DATA PROGRAMMING
(FOR HOME PBX AND VISITOR PBX)
ROAMING PS...

Page 89

CHAPTER 3 SYSTEM DATA PROGRAMMING
Multi-Site Roaming Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 81
Confirming Network Numbering Plan
Confirm whether the network adopts Open Numbering System or Closed Numbering System for
the network numbering plan.
NOTE:The System data stored in the memory of the DBM (PN-AP00-A) card can be saved,
loaded, and verified from the MAT.
To save; Memory Area No. : A, Memory Address: 00900-10870
To load or verify; File Extension : DMA 

Page 90

NEAX2000 IVS2WCS System Manual (PCS)Page 82ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Multi-Site Roaming Programming
Network Numbering Plan Programming
DESCRIPTION DATA
Assign an access code for LCR Group 0-3.
For Closed Numbering System, assign the
second data to A129 (LCR Group 3).
(1)
(2)Y=0-3 (Numbering Group 0-3)
X-XXXX: Access Code
A126: LCR Group 0
A127: LCR Group 1
A128: LCR Group 2
A129: LCR Group 3
Specify the number of digits and the first
digit for station number.
(1)...