Page 31
CHAPTER 2 INSTALLATION Precautions NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 23 Tu r n i n g P o w e r O N (1) Check the switch position of each PZ-PW121 card before turning power on. Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for each country (AC120V or AC240V). Make sure that the battery mode selector switch is positioned as shown below to meet the kind of battery: (2) Turn the SW1 switches of all the PZ-PW121 cards to ON. First, turn ON...
Page 32
NEAX2000 IVS2WCS System Manual (PCS)Page 24ND-70920 (E), Issue 1.0 CHAPTER 2 INSTALLATION Precautions Tu r n i n g P o w e r O F F (1) Before turning power off ensure that all circuits are not in use. (2) Turn the SW1 switches of all the PZ-PW121 cards to OFF. First, turn OFF PIM0. Then, turn OFF PIM1 to PIM7.
Page 33
CHAPTER 2 INSTALLATION Required Equipment NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 25 REQUIRED EQUIPMENT Ta b l e 2 - 1shows the equipment required to provide the WCS interface to the system. Table 2-1 WCS Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS PZ-PW122 (DC/DC PWR)–48V Power supply card for ZT 1-8 One per PIM 16 ZT powered /card PWR CNT CA-D Power Control Cable-D (between PW121/PW122 and BWB)1-7 For PIM1-7 PWR CNT CA-E Power Control Cable-E (between PW121/PW122 and...
Page 34
NEAX2000 IVS2WCS System Manual (PCS)Page 26ND-70920 (E), Issue 1.0 CHAPTER 2 INSTALLATION Required Equipment PN-24DTA-C (24DTI)24-channel DTI card 1-8 For Roaming PN-30DTC-A (30DTI)30-channel DTI card 1-4 PN-SC01 (DCH) D-channel Handler card 1-8 PN-AP00-A (DBM) Roaming Data Base Module card 1 Table 2-1 WCS Required Equipment (Continued) EQUIPMENT DESCRIPTION QUANTITY REMARKS
Page 35
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 27 INSTALLATION PROCEDURE Install the equipment for WCS according to the procedure shown inFigure 2-2.Figure 2-3shows the procedure for Multi-Site Roaming. Figure 2-2 Installation Procedure START MOUNTING PW122 CARD Pag e 31 Pag e 29 More than 128 PS required? Ye s No CONNECTION OF ZT MOUNTING CSH CARDPage 32 END MOUNTING CSI CARDPage 33 Page 34 MOUNTING EXPMEM CARD
Page 36
NEAX2000 IVS2WCS System Manual (PCS)Page 28ND-70920 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Figure 2-3 Installation Procedure for Multi-Site Roaming START CABLE CONNECTION END MOUNTING DTI, DCHPag e 37 Pag e 37AND DBM CARD VIA MDF SELECTION OF PLO IN MP CARD
Page 37
CHAPTER 2 INSTALLATION Mounting PW122 Card NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 29 MOUNTING PW122 CARD Mount the PW122 card into the PIM as shown inFigure 2-4. (1) Attach four screws preliminary to the PZ-PW122 card. (2) Mount the PZ-PW122 card into the PIM which accommodates the CSI cards, and fasten the screws. NOTE:Screws are attached to the PZ-PW122 card. Figure 2-4 Mounting PZ-PW122 into PIM ATTENTIONContents Static SensitiveHa ndl ing Prec au tio ns Requ ired PIM PZ-PW122
Page 38
NEAX2000 IVS2WCS System Manual (PCS)Page 30ND-70920 (E), Issue 1.0 CHAPTER 2 INSTALLATION Mounting PW122 Card (3) Connect the PWR CNT CA-E or PWR CNT CA-D, and POWER OUTPUT CABLE (–48 V, E) to the PZ-PW122 card as shown inFigure 2-5. Figure 2-5 Cable Connection between PZ-PW121/PZ-PW122 and BWB ATTENTIONContents Static SensitiveHa ndl ing Prec au tio ns Requ ired PWR CNT CA-E (FOR PIM0) PWR CNT CA-D (FOR PIM1 TO PIM7)PWR0B PWR1 PZ-PW121 BWB (BACK WIRING BOARD)PIM PWR0CPWR0A POWER OUTPUT CABLE (+90 V, CR,...
Page 39
CHAPTER 2 INSTALLATION Mounting EXPMEM Card NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 31 MOUNTING EXPMEM CARD The EXPMEM (PZ-M537) card is required when the number of PS is more than 128. (1) Confirm the correct switch settings. SeeCHAPTER 4 (2) Mount the EXPMEM card on the MP card. For details, refer to the Installation Procedure Manual. (3) Then, mount the MP card into the MP slot of PIM0.ATTENTIONContents Static SensitiveHa ndl ing Prec au tio ns Requ ired
Page 40
NEAX2000 IVS2WCS System Manual (PCS)Page 32ND-70920 (E), Issue 1.0 CHAPTER 2 INSTALLATION Mounting CSH Card MOUNTING CSH CARD (1) Before mounting the CSH (PN-SC03-A) card, set the MB switch to UP position, and set the other switches to appropriate position. SeeCHAPTER 4. (2) Mount the CSH card in the AP slots of PIM0 through PIM7. PIM0-7: AP00-AP11 slots The AP11 slot on PIM0 is available only when the FP card is not mounted on the FP11 slot on PIM0. (3) After mounting the card, set the MB switch to DOWN...